- Dehaeze, T., Mattenet, M. M., & Collette, C., *Sample Stabilization For Tomography Experiments In Presence Of Large Plant Uncertainty*, In MEDSI'18 (pp. 153–157) (2018). Geneva, Switzerland: JACoW Publishing. ([[file:dehaeze18_sampl_stabil_for_tomog_exper/index.org][link]])
- Dehaeze, T., Vermat, M., & Christophe, C., *Complementary filters shaping using $H_\infty$ synthesis*, In 7th International Conference on Control, Mechatronics and Automation (ICCMA) (pp. 459–464) (2019). ([[file:dehaeze19_desig_compl_filte/index.org][link]])
- Dehaeze, T., & Collette, C., *Active damping of rotating platforms using Integral Force Feedback*, In Proceedings of the International Conference on Modal Analysis Noise and Vibration Engineering (ISMA) (2020). ([[file:dehaeze20_activ_dampin_rotat_platf_integ_force_feedb/index.org][link]])
- Verma, M., Dehaeze, T., Zhao, G., Watchi, J., & Collette, C., *Virtual sensor fusion for high precision control, Mechanical Systems and Signal Processing*, 150, 107241 (2020). http://dx.doi.org/10.1016/j.ymssp.2020.107241 ([[file:personnal-papers/verma20_virtual_sensor_fusion_high_precis_contr.pdf][pdf]])
- Verma, M., Lafarga, V., Dehaeze, T., & Collette, C., *Multi-degree of freedom isolation system with high frequency roll-off for drone camera stabilization*, IEEE Access, (2020). http://dx.doi.org/10.1109/ACCESS.2020.3027066 ([[file:personnal-papers/verma20_multi_degree_freed_isolat_system.pdf][pdf]])
[[file:test-bench-piezo-amplifiers/index.org][Voltage Amplifiers for Piezoelectric Actuators]]
#+begin_quote
Voltage amplifiers for capacitive loads (piezoelectric actuators) are measured in term of dynamics from input voltage to output voltage.
Their output impedance are also measured.
#+end_quote
[[file:attocube-test-bench/index.org][Attocube]]
#+begin_quote
The Attocube (a fiber based interferometer) is tested.
Its noise characteristics as well as non-linearities are measured.
#+end_quote
** Amplified Piezoelecric Actuator
[[file:test-bench-apa/index.org][Amplified Piezoelectric Actuator - Test bench and Finite Element Model]]
#+begin_quote
A test bench is used to characterise the performances of an Amplified Piezoelectric Actuator (APA).
The dynamics of the system is identified and compared with a Finite Element Model (FEM).
#+end_quote
[[file:encoder-test-bench/index.org][Encoder in parallel with an Amplified Piezoelectric Actuator]]
#+begin_quote
An encoder is fixed in parallel with an amplified piezoelectric actuator.
The transfer function from the actuator to the motions measured by the encoder is identified.
#+end_quote
[[file:test-bench-force-sensor/index.org][Piezoelectric Stack as Force Sensor]]
#+begin_quote
A part of a piezoelectric stack can be used as a force sensor.
Then, the force sensors is collocated with the part of the stack used as an actuator and Integral Force Feedback control strategy can be used to add damping in the system.
This is performed on an Amplified Piezoelectric Actuator
#+end_quote
[[file:sensor-fusion-test-bench/index.org][Sensor Fusion of Inertial Sensors]]
#+begin_quote
A geophone and a accelerometer are experimentally fused together using complementary filters.
The goal is to form a /super sensor/ that has better noise characteristics than the individual sensors.