Tags :
Right Half Plane (RHP) Zeros are present in a broad range of systems.
- SISO RHP zeros:
- \(G(z) = 0\). The real part of \(z\) is positive
- MIMO RHP zeros:
- RHP zeros of the determinant of the transfer function matrix
- For MIMO plants, the zero is associated with an output direction
- Consequences:
- Non minimum phase
- Usually, if looking at the step response, at first the response goes in the wrong direction