title = "Respect the unstable"
|
||
author = ["Thomas Dehaeze"]
|
||
draft = false
|
||
+++
|
||
|
||
Tags
|
||
:
|
||
|
||
|
||
Reference
|
||
: ([Stein 2003](#orge299f80))
|
||
|
||
Author(s)
|
||
: Stein, G.
|
||
|
||
Year
|
||
: 2003
|
||
|
||
|
||
## Introduction {#introduction}
|
||
|
||
> The second trend has been evident at our conferences, and certainly in our journal, over the years.
|
||
> This trend is the increasing worship of abstract mathematical results in control at the expense of more specific examinations of their practical, physical consequences.
|
||
|
||
<div class="important">
|
||
<div></div>
|
||
|
||
**Basic facts about unstable plants**:
|
||
|
||
- Unstable systems are fundamentally, and quantifiably more difficult to control than stable ones
|
||
- Controllers for unstable systems are operationally critical
|
||
- Closed-loop systems with unstable components are only locally stable
|
||
|
||
</div>
|
||
|
||
|
||
## The Bode Integrals {#the-bode-integrals}
|
||
|
||
<div class="important">
|
||
<div></div>
|
||
|
||
**Bode Integrals**:
|
||
|
||
The first integral applies to stable plants and the second to unstable plants.
|
||
They are valid for every stabilizing controller, assuming only that both plan and controller have finite bandwidths.
|
||
In words, the integrals state that the log of magnitude of sensitivity function of a SISO feedback system, integrated over frequency, is constant.
|
||
The constant is zero for stable plants, and it is positive for unstable ones.
|
||
It becomes larger as the number of unstable poles increases and/or as the poles more farther into the right-half plane.
|
||
|
||
\begin{align}
|
||
\int\_0^\infty \ln |S(j\omega)| d \omega & = 0 \label{eq:bode\_integral\_stable} \\\\\\
|
||
\int\_0^\infty \ln |S(j\omega)| d \omega & = \pi \sum\_{p \in P} \text{Re}(p) \label{eq:bode\_integral\_unstable}
|
||
\end{align}
|
||
|
||
</div>
|
||
|
||
|
||
## A Bode Integral Interpretation {#a-bode-integral-interpretation}
|
||
|
||
Bode integral can be thought as **conservation laws**.
|
||
They state that a certain quantity, the integrated value of the log of the magnitude of the sensitivity function, is conserved under the action of feedback.
|
||
The total amount of this quantity is always the same.
|
||
It is equal to zero for stable plant/compensator pairs, and it is equal to some fixed positive amount for unstable ones.
|
||
|
||
Since we are talking about the log of sensitivity magnitude, it follows that negative values are good, and positive values are bad.
|
||
|
||
<div class="definition">
|
||
<div></div>
|
||
|
||
It is curious, somehow, that our field has not adopted a name for this quantity being conserved (i.e. the integrated log of sensitivity magnitude).
|
||
It is here proposed to call it **dirt**
|
||
|
||
</div>
|
||
|
||
The job of a serious control designer is then to more dirt from one place to another, using appropriate tools, without being able to get rid of any of it (illustrated in Figure [1](#orgf166bde)).
|
||
|
||
<a id="orgf166bde"></a>
|
||
|
||
{{< figure src="/ox-hugo/stein03_serious_design.png" caption="Figure 1: Sensitivity reduction at low frequency unavoidably leads to sensitivity increase at higher frequencies" >}}
|
||
|
||
In the same spirit, the job of a more academic control designer with more abstract tools such as LQG, \\(\mathcal{H}\_\infty\\), is to set parameters (weights) of a synthesis machine to adjust the contours of the machine's digging blades to get just the right shape for the sensitivity function (Figure [2](#org29aa88f)).
|
||
|
||
<a id="org29aa88f"></a>
|
||
|
||
{{< figure src="/ox-hugo/stein03_formal_design.png" caption="Figure 2: Sensitivity shaping automated by modern control tools" >}}
|
||
|
||
|
||
## Available bandwidth {#available-bandwidth}
|
||
|
||
An argument is sometimes made that the Bode integrals are not really restrictive because we only seek to dig holes over finite frequency bands.
|
||
We then have an infinite frequency range left over into which to dump the dirt, so we can make the layer arbitrarily thin (Figure [3](#orgf23d7a5)).
|
||
|
||
<a id="orgf23d7a5"></a>
|
||
|
||
{{< figure src="/ox-hugo/stein03_spreading_it_thin.png" caption="Figure 3: It is possible to spead the increase of the sensitivity function over a larger frequency band" >}}
|
||
|
||
The weakness of this argument is evident from standard classical theory.
|
||
A thin layer, say with \\(\ln|S| = \epsilon\\) requires a loop transfer function whose Nyquist diagram falls on a near-unit circle, centered at \\((-1 + j 0)\\) with a radius \\(\approx (1-\epsilon)\\), over a wide frequency range.
|
||
This means that the loop cannot simply attenuate at high frequencies but must attenuate in a very precise way.
|
||
The loop must maintain very good frequency response fidelity over wide frequency ranges.
|
||
|
||
But a key fact about physical systems is that they do not exhibit good frequency response fidelity beyond a certain bandwidth.
|
||
This is due to uncertain or unmodeled dynamics in the plant, to digital control implementations, to power limits, to nonlinearities, and to many other factors.
|
||
Let us call that bandwidth the available bandwidth" \\(\Omega\_a\\), to distinguish it from other bandwidths such as crossover or \\(3-dB\\) magnitude loss.
|
||
The available bandwidth is the frequency up to which we can keep \\(G(j\omega) K(j\omega)\\) close to a nominal design and beyond which we can only guarantee that the actual loop magnitude will attenuate rapidly enough (e.g. \\(|G(j\omega) K(j\omeg\\))| < δ/ω^2$).
|
||
In today's popular robust control jargon, the available bandwidth is the frequency range over which the unstructured multiplicative perturbations are substantially less than unity.
|
||
|
||
Note that the available bandwidth is not a function of the compensator or of the control design process.
|
||
Rather, it is an a priori constraint imposed by the physical hardware we use in the control loop.
|
||
Most importantly, the available bandwidth is always finite.
|
||
|
||
Given all this, Bode's integrals really reduce to finite integrals over the range \\(0 \ge \omega \ge \Omega\_a\\):
|
||
|
||
\begin{align}
|
||
\int\_0^{\Omega\_a} \ln{|S(j \omega)|} d \omega &= \delta \\\\\\
|
||
\int\_0^{\Omega\_a} \ln{|S(j \omega)|} d \omega &= \pi \sum\_{p \in P} \text{Re}(p) + \delta
|
||
\end{align}
|
||
|
||
All the action of the feedback design, the sensitivity improvements as well as the sensitivity deterioration, must occur within \\(0 \ge \omega \ge \Omega\_a\\).
|
||
Only a small error \\(\delta\\) occurs outside that range, associated with the tail of the complete integrals.
|
||
|
||
|
||
|
||
## Bibliography {#bibliography}
|
||
|
||
<a id="orge299f80"></a>Stein, Gunter. 2003. “Respect the Unstable.” _IEEE Control Systems Magazine_ 23 (4). IEEE:12–25.
|