@@ -17,9 +17,9 @@ There are two main technique for force sensors:
|
||||
|
||||
The choice between the two is usually based on whether the measurement is static (strain gauge) or dynamics (piezoelectric).
|
||||
|
||||
Main differences between the two are shown in Figure [1](#org40d75e8).
|
||||
Main differences between the two are shown in Figure [1](#org921c881).
|
||||
|
||||
<a id="org40d75e8"></a>
|
||||
<a id="org921c881"></a>
|
||||
|
||||
{{< figure src="/ox-hugo/force_sensor_piezo_vs_strain_gauge.png" caption="Figure 1: Piezoelectric Force sensor VS Strain Gauge Force sensor" >}}
|
||||
|
||||
@@ -29,18 +29,18 @@ Main differences between the two are shown in Figure [1](#org40d75e8).
|
||||
|
||||
### Dynamics and Noise of a piezoelectric force sensor {#dynamics-and-noise-of-a-piezoelectric-force-sensor}
|
||||
|
||||
An analysis the dynamics and noise of a piezoelectric force sensor is done in ([Fleming 2010](#orgc01e36f)) ([Notes]({{< relref "fleming10_nanop_system_with_force_feedb" >}})).
|
||||
An analysis the dynamics and noise of a piezoelectric force sensor is done in ([Fleming 2010](#org26fffc0)) ([Notes]({{< relref "fleming10_nanop_system_with_force_feedb" >}})).
|
||||
|
||||
|
||||
### Manufacturers {#manufacturers}
|
||||
|
||||
| Manufacturers | Links | Country |
|
||||
|---------------|------------------------------------------------------------------------------------------------|---------|
|
||||
| PCB | [link](https://www.pcb.com/products/productfinder.aspx?tx=17) | USA |
|
||||
| HBM | [link](https://www.hbm.com/en/6107/force-sensors-with-flange-mounting/) | Germany |
|
||||
| Kistler | [link](https://www.kistler.com/fr/produits/composants/capteurs-de-force/?pfv%5Fmetrics=metric) | Swiss |
|
||||
| MMF | [link](https://www.mmf.de/force%5Ftransducers.htm) | Germany |
|
||||
| Sinocera | [link](http://www.china-yec.net/sensors/) | China |
|
||||
| Manufacturers | Country |
|
||||
|---------------------------------------------------------------------------------------------------|---------|
|
||||
| [PCB](https://www.pcb.com/products/productfinder.aspx?tx=17) | USA |
|
||||
| [HBM](https://www.hbm.com/en/6107/force-sensors-with-flange-mounting/) | Germany |
|
||||
| [Kistler](https://www.kistler.com/fr/produits/composants/capteurs-de-force/?pfv%5Fmetrics=metric) | Swiss |
|
||||
| [MMF](https://www.mmf.de/force%5Ftransducers.htm) | Germany |
|
||||
| [Sinocera](http://www.china-yec.net/sensors/) | China |
|
||||
|
||||
|
||||
### Signal Conditioner {#signal-conditioner}
|
||||
@@ -65,16 +65,16 @@ However, if a charge conditioner is used, the signal will be doubled.
|
||||
|
||||
### Manufacturers {#manufacturers}
|
||||
|
||||
| Manufacturers | Links | Country |
|
||||
|---------------|----------------------------------------------------------------------------|----------------|
|
||||
| Sensel | [link](https://www.sensel-measurement.fr/en/3-load-cell) | France |
|
||||
| Omega | [link](https://www.omega.com/en-us/resources/load-cells) | United Kingdom |
|
||||
| Megatron | [link](https://www.megatron.de/en/category/load-cells.html) | Germany |
|
||||
| PCB | [link](https://www.pcb.com/products/product-finder?tx=19) | USA |
|
||||
| Interface | [link](https://quickship.interfaceforce.com/product-category/load-cells/) | USA |
|
||||
| Althen | [link](https://www.althensensors.com/sensors/weighing-sensors-load-cells/) | Netherlands |
|
||||
| Manufacturers | Country |
|
||||
|--------------------------------------------------------------------------------|----------------|
|
||||
| [Sensel](https://www.sensel-measurement.fr/en/3-load-cell) | France |
|
||||
| [Omega](https://www.omega.com/en-us/resources/load-cells) | United Kingdom |
|
||||
| [Megatron](https://www.megatron.de/en/category/load-cells.html) | Germany |
|
||||
| [PCB](https://www.pcb.com/products/product-finder?tx=19) | USA |
|
||||
| [Interface](https://quickship.interfaceforce.com/product-category/load-cells/) | USA |
|
||||
| [Althen](https://www.althensensors.com/sensors/weighing-sensors-load-cells/) | Netherlands |
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
<a id="orgc01e36f"></a>Fleming, A.J. 2010. “Nanopositioning System with Force Feedback for High-Performance Tracking and Vibration Control.” _IEEE/ASME Transactions on Mechatronics_ 15 (3):433–47. <https://doi.org/10.1109/tmech.2009.2028422>.
|
||||
<a id="org26fffc0"></a>Fleming, A.J. 2010. “Nanopositioning System with Force Feedback for High-Performance Tracking and Vibration Control.” _IEEE/ASME Transactions on Mechatronics_ 15 (3):433–47. <https://doi.org/10.1109/tmech.2009.2028422>.
|
||||
|