@@ -4,13 +4,13 @@ author = ["Thomas Dehaeze"]
draft = false
+++
### Backlinks {#backlinks}
Backlinks:
- [Signal Conditioner]({{< relref "signal_conditioner" >}})
- [Sensors]({{< relref "sensors" >}})
- [Nanopositioning system with force feedback for high-performance tracking and vibration control]({{< relref "fleming10_nanop_system_with_force_feedb" >}})
- [Collocated Control]({{< relref "collocated_control" >}})
- [Position Sensors]({{< relref "position_sensors" >}})
- [Signal Conditioner]({{< relref "signal_conditioner" >}})
Tags
:
@@ -21,7 +21,7 @@ Tags
### Dynamics and Noise of a piezoelectric force sensor {#dynamics-and-noise-of-a-piezoelectric-force-sensor}
An analysis the dynamics and noise of a piezoelectric force sensor is done in ([Fleming 2010](#org82df6e1)) ([Notes]({{< relref "fleming10_nanop_system_with_force_feedb" >}})).
An analysis the dynamics and noise of a piezoelectric force sensor is done in ([Fleming 2010](#org25f6243)) ([Notes]({{< relref "fleming10_nanop_system_with_force_feedb" >}})).
### Manufacturers {#manufacturers}
@@ -36,17 +36,10 @@ An analysis the dynamics and noise of a piezoelectric force sensor is done in ([
### Signal Conditioner {#signal-conditioner}
The voltage generated by the piezoelectric material generally needs to be amplified.
The voltage generated by the piezoelectric material generally needs to be amplified using a [Signal Conditioner]({{< relref "signal_conditioner" >}}).
Either **charge** amplifiers or **voltage** amplifiers can be used.
| Manufacturers | Links | Country |
|---------------|------------------------------------------------------------------------------------|---------|
| PCB | [link](https://www.pcb.com/products?m=482c15) | USA |
| HBM | [link](https://www.hbm.com/en/2660/paceline-cma-charge-amplifier-analogamplifier/) | Germany |
| Kistler | [link](https://www.kistler.com/fr/produits/composants/conditionnement-de-signal/) | Swiss |
| MMF | [link](https://www.mmf.de/signal%5Fconditioners.htm) | Germany |
### Effect of using multiple Stacks in series of parallels {#effect-of-using-multiple-stacks-in-series-of-parallels}
@@ -60,4 +53,4 @@ However, if a charge conditioner is used, the signal will be doubled.
## Bibliography {#bibliography}
<a id="org82df6e1"></a>Fleming, A.J. 2010. “Nanopositioning System with Force Feedback for High-Performance Tracking and Vibration Control.” _IEEE/ASME Transactions on Mechatronics_ 15 (3):43347. <https://doi.org/10.1109/tmech.2009.2028422>.
<a id="org25f6243"></a>Fleming, A.J. 2010. “Nanopositioning System with Force Feedback for High-Performance Tracking and Vibration Control.” _IEEE/ASME Transactions on Mechatronics_ 15 (3):43347. <https://doi.org/10.1109/tmech.2009.2028422>.