@ -2070,8 +2070,9 @@ Typical angular stroke for such flexible joints is expected.
:UNNUMBERED: t
:END:
- Resonances should stay between 5Hz and 50Hz for payload masses up to 50kg
- This corresponds to strut stiffnesses of $k \approx 10^5 - 10^6\,[N/m]$
The axial stiffness of the struts (between two flexible joints) should be equal to $\approx 10^5 - 10^6\,[N/m]$.
If voice coils are used, this corresponds to the axial stiffness of the membrane guiding the moving part of the voice coil.
*** Actuator Force
:PROPERTIES:
@ -2084,7 +2085,6 @@ Based on simulations:
If static deflection is to be compensated by the actuator, $\approx 100\,[N]$ of continuous force is required for each actuator.
*** Actuator Stroke
:PROPERTIES:
:UNNUMBERED: t

View File

@ -64,7 +64,7 @@
url = {https://doi.org/10.1016/j.jsv.2006.07.050},
}
@techreport{collette11_review,
@misc{collette11_review,
author = {Collette, C and Artoos, K and Guinchard, M and Janssens, S and Carmona Fernandez, P and Hauviller, C},
institution = {cern},
title = {Review of sensors for low frequency seismic vibration measurement},