Update conclusion
This commit is contained in:
parent
f198f17028
commit
5c5f080157
1421
index.html
1421
index.html
File diff suppressed because it is too large
Load Diff
@ -2070,8 +2070,9 @@ Typical angular stroke for such flexible joints is expected.
|
||||
:UNNUMBERED: t
|
||||
:END:
|
||||
|
||||
- Resonances should stay between 5Hz and 50Hz for payload masses up to 50kg
|
||||
- This corresponds to strut stiffnesses of $k \approx 10^5 - 10^6\,[N/m]$
|
||||
The axial stiffness of the struts (between two flexible joints) should be equal to $\approx 10^5 - 10^6\,[N/m]$.
|
||||
|
||||
If voice coils are used, this corresponds to the axial stiffness of the membrane guiding the moving part of the voice coil.
|
||||
|
||||
*** Actuator Force
|
||||
:PROPERTIES:
|
||||
@ -2084,7 +2085,6 @@ Based on simulations:
|
||||
|
||||
If static deflection is to be compensated by the actuator, $\approx 100\,[N]$ of continuous force is required for each actuator.
|
||||
|
||||
|
||||
*** Actuator Stroke
|
||||
:PROPERTIES:
|
||||
:UNNUMBERED: t
|
||||
|
2
ref.bib
2
ref.bib
@ -64,7 +64,7 @@
|
||||
url = {https://doi.org/10.1016/j.jsv.2006.07.050},
|
||||
}
|
||||
|
||||
@techreport{collette11_review,
|
||||
@misc{collette11_review,
|
||||
author = {Collette, C and Artoos, K and Guinchard, M and Janssens, S and Carmona Fernandez, P and Hauviller, C},
|
||||
institution = {cern},
|
||||
title = {Review of sensors for low frequency seismic vibration measurement},
|
||||
|
Loading…