nass-micro-station-measurem.../modal-analysis/measurement.org

35 KiB

Modal Analysis - Measurement

Introduction   ignore

The goal is to measure the dynamic of the Micro-Station and to extract Frequency Response Functions.

ZIP file containing the data and matlab files   ignore

All the files (data and Matlab scripts) are accessible here.

Instrumentation Used

In order to perform to Modal Analysis and to obtain first a Response Model, the following devices are used:

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/instrumentation/oros.png
Acquisition system: OROS

The acquisition system permits to auto-range the inputs (probably using variable gain amplifiers) the obtain the maximum dynamic range. This is done before each measurement. Anti-aliasing filters are also included in the system.

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/instrumentation/accelero_M393B05.png
Accelerometer used: M393B05
Sensitivity 10V/g
Measurement Range 0.5 g pk
Broadband Resolution 0.000004 g rms
Frequency Range 0.7 to 450Hz
Resonance Frequency > 2.5kHz
393B05 Accelerometer Data Sheet

Tests have been conducted to determine the most suitable Hammer tip. This has been found that the softer tip gives the best results. It excites more the low frequency range where the coherence is low, the overall coherence was improved.

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/instrumentation/instrumented_hammer.png
Instrumented Hammer
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/instrumentation/hammer_tips.png
Hammer tips

The accelerometers are glued on the structure.

Structure Preparation and Test Planning

Structure Preparation

All the stages are turned ON. This is done for two reasons:

  • Be closer to the real dynamic of the station in used
  • If the control system of stages are turned OFF, this would results in very low frequency modes un-identifiable with the current setup, and this will also decouple the dynamics which would not be the case in practice

This is critical for the translation stage and the spindle as their is no stiffness in the free DOF (air-bearing for the spindle for instance).

The alternative would have been to mechanically block the stages with screws, but this may result in changing the modes.

The stages turned ON are:

  • Translation Stage
  • Tilt Stage
  • Spindle and Slip-Ring
  • Hexapod

The top part representing the NASS and the sample platform have been removed in order to reduce the complexity of the dynamics and also because this will be further added in the model inside Simscape.

All the stages are moved to their zero position (Ty, Ry, Rz, Slip-Ring, Hexapod).

All other elements have been remove from the granite such as another heavy positioning system.

Test Planing

The goal is to identify the full $N \times N$ FRF matrix $H$ (where $N$ is the number of degree of freedom of the system):

\begin{equation} H_{jk} = \frac{X_j}{F_k} \end{equation}

However, from only one column or one line of the matrix, we can compute the other terms thanks to the principle of reciprocity.

Either we choose to identify $\frac{X_k}{F_i}$ or $\frac{X_i}{F_k}$ for any chosen $k$ and for $i = 1,\ ...,\ N$.

We here choose to identify $\frac{X_i}{F_k}$ for practical reasons:

  • it is easier to glue the accelerometers on all the stages and excite only a one particular point than doing the opposite

The measurement thus consists of:

  • always excite the structure at the same location with the Hammer
  • Move the accelerometers to measure all the DOF of the structure

We will measured 3 columns (3 impacts location) in order to have some redundancy.

Location of the Accelerometers

4 tri-axis accelerometers are used for each solid body.

Only 2 could have been used as only 6DOF have to be measured, however, we have chosen to have some redundancy.

This could also help us identify measurement problems or flexible modes is present.

The position of the accelerometers are:

In total, 23 accelerometers are used: 69 DOFs are thus measured.

The position and orientation of all the accelerometers used are shown on figure fig:nass-modal-test.

The precise determination of the position of each accelerometer is done using the SolidWorks model (shown on figure fig:location_accelerometers).

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/accelerometers/accelerometers_granite2_overview.jpg
Accelerometers located on the top granite
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/accelerometers/accelerometers_ty_overview.jpg
Accelerometers located on top of the translation stage
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/accelerometers/accelerometers_hexa_overview.jpg
Accelerometers located on the Hexapod
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/nass-modal-test.png
Position and orientation of the accelerometer used
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/location_accelerometers.png
Position of the accelerometers using SolidWorks

The precise position of all the 23 accelerometer with respect to a frame located at the point of interest (located 270mm above the top platform of the hexapod) is shown below. The values are in meter. They are contained in the mat/id31_nanostation.cfg file.

  cat mat/id31_nanostation.cfg | grep NODES -A 23 | sed '/\s\+[0-9]\+/!d' | sed 's/\(.*\)\s\+0\s\+.\+/\1/' > mat/acc_pos.txt

We then import that on matlab, and sort them.

  acc_pos = readtable('mat/acc_pos.txt', 'ReadVariableNames', false);
  acc_pos = table2array(acc_pos(:, 1:4));
  [~, i] = sort(acc_pos(:, 1));
  acc_pos = acc_pos(i, 2:4);

The positions of the sensors relative to the point of interest are shown below (table tab:position_accelerometers).

ID x [mm] y [mm] z [mm]
1 -64 -64 -270
2 -64 64 -270
3 64 64 -270
4 64 -64 -270
5 -385 -300 -417
6 -420 280 -417
7 420 280 -417
8 380 -300 -417
9 -475 -414 -427
10 -465 407 -427
11 475 424 -427
12 475 -419 -427
13 -320 -446 -786
14 -480 534 -786
15 450 534 -786
16 295 -481 -786
17 -730 -526 -951
18 -735 814 -951
19 875 799 -951
20 865 -506 -951
21 -155 -90 -594
22 0 180 -594
23 155 -90 -594
position of the accelerometers

Hammer Impacts

Only 3 impact points are used.

The impact points are shown on figures fig:hammer_x, fig:hammer_y and fig:hammer_z.

We chose this excitation point as it seems to excite all the modes in the frequency band of interest and because it provides good coherence for all the accelerometers.

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/impacts/hammer_x.gif
Hammer Blow in the X direction
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/impacts/hammer_y.gif
Hammer Blow in the Y direction
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/img/impacts/hammer_z.gif
Hammer Blow in the Z direction

Signal Processing

Averaging

The measurements are averaged 10 times corresponding to 10 hammer impacts in order to reduce the effect of random noise. The parameters for the impact test are shown on table tab:meas_parameters.

Start Delay -5%
Number of lines 801 lines
Trigger Threshold 300N
Trigger Hysteresis 100mN
FRF Average 10
Impact test parameters

Windowing

Windowing is used on the force and response signals.

A boxcar window (figure fig:windowing_force_signal) is used for the force signal as once the impact on the structure is done, the measured signal is meaningless. The parameters are:

  • Start: $3\%$
  • Stop: $7\%$
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/windowing_force_signal.png
Window used for the force signal

An exponential window (figure fig:windowing_response_signal) is used for the response signal as we are measuring transient signals and most of the information is located at the beginning of the signal. The parameters are:

  • FlatTop:

    • Start: $3\%$
    • Stop: $2.96\%$
  • Decreasing point:

    • X: $60.4\%$
    • Y: $14.7\%$
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/windowing_response_signal.png
Window used for the response signals

Force and Response signals

Let's load some obtained data to look at the force and response signals.

  meas1_raw = load('mat/meas_raw_1.mat');

Raw Force Data

The force input for the first measurement is shown on figure fig:raw_data_force. We can see 10 impacts, one zoom on one impact is shown on figure fig:raw_data_force_zoom.

The Fourier transform of the force is shown on figure fig:fourier_transfor_force_impact. This has been obtained without any windowing.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/raw_data_force.png
Raw Force Data from Hammer Blow
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/raw_data_force_zoom.png
Raw Force Data from Hammer Blow - Zoom
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/fourier_transfor_force_impact.png
Fourier Transform of the 10 force impacts for the first measurement

Raw Response Data

The response signal for the first measurement is shown on figure fig:raw_data_acceleration. One zoom on one response is shown on figure fig:raw_data_acceleration_zoom.

The Fourier transform of the response signals is shown on figure fig:fourier_transform_response_signals. This has been obtained without any windowing.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/raw_data_acceleration.png
Raw Acceleration Data from Accelerometer
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/raw_data_acceleration_zoom.png
Raw Acceleration Data from Accelerometer - Zoom
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/fourier_transform_response_signals.png
Fourier transform of the measured response signals

Computation of one Frequency Response Function

Now that we have obtained the Fourier transform of both the force input and the response signal, we can compute the Frequency Response Function from the force to the acceleration.

We then compare the result obtained with the FRF computed by the modal software (figure fig:frf_comparison_software).

The slight difference can probably be explained by the use of windows.

In the following analysis, FRF computed from the software will be used.

  meas1 = load('mat/meas_frf_coh_1.mat');
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/frf_comparison_software.png
Comparison of the computed FRF from the Fourier transform and using the modal software

Frequency Response Functions and Coherence Results

Let's see one computed Frequency Response Function and one coherence in order to attest the quality of the measurement.

First, we load the data.

  meas1 = load('mat/meas_frf_coh_1.mat');

And we plot on figure fig:frf_result_example the frequency response function from the force applied in the $X$ direction at the location of the accelerometer number 11 to the acceleration in the $X$ direction as measured by the first accelerometer located on the top platform of the hexapod.

The coherence associated is shown on figure fig:frf_result_example.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/frf_result_example.png
Example of one measured FRF
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/coh_result_example.png
Example of one measured Coherence

Generation of a FRF matrix and a Coherence matrix from the measurements

We want here to combine all the Frequency Response Functions measured into one big array called the Frequency Response Matrix.

The frequency response matrix is an $n \times p \times q$:

  • $n$ is the number of measurements: $23 \times 3$ (23 accelerometers measuring 3 directions each)
  • $p$ is the number of excitation inputs: $3$
  • $q$ is the number of frequency points $\omega_i$

Thus, the FRF matrix is an $69 \times 3 \times 801$ matrix. We do the same thing for the coherence matrix.

For each frequency point $\omega_i$, we obtain a 2D matrix:

\begin{equation} \text{FRF}(\omega_i) = \begin{bmatrix} \frac{D_{1_x}}{F_x}(\omega_i) & \frac{D_{1_x}}{F_y}(\omega_i) & \frac{D_{1_x}}{F_z}(\omega_i) \\ \frac{D_{1_y}}{F_x}(\omega_i) & \frac{D_{1_y}}{F_y}(\omega_i) & \frac{D_{1_y}}{F_z}(\omega_i) \\ \frac{D_{1_z}}{F_x}(\omega_i) & \frac{D_{1_z}}{F_y}(\omega_i) & \frac{D_{1_z}}{F_z}(\omega_i) \\ \frac{D_{2_x}}{F_x}(\omega_i) & \frac{D_{2_x}}{F_y}(\omega_i) & \frac{D_{2_x}}{F_z}(\omega_i) \\ \vdots & \vdots & \vdots \\ \frac{D_{23_z}}{F_x}(\omega_i) & \frac{D_{23_z}}{F_y}(\omega_i) & \frac{D_{23_z}}{F_z}(\omega_i) \\ \end{bmatrix} \end{equation}

We generate such FRF matrix from the measurements using the following script.

  n_meas = 24;
  n_acc = 23;

  dirs = 'XYZ';

  % Number of Accelerometer * DOF for each acccelerometer / Number of excitation / frequency points
  FRFs = zeros(3*n_acc, 3, 801);
  COHs = zeros(3*n_acc, 3, 801);

  % Loop through measurements
  for i = 1:n_meas
    % Load the measurement file
    meas = load(sprintf('mat/meas_frf_coh_%i.mat', i));

    % First: determine what is the exitation (direction and sign)
    exc_dir = meas.FFT1_AvXSpc_2_1_RMS_RfName(end);
    exc_sign = meas.FFT1_AvXSpc_2_1_RMS_RfName(end-1);
    % Determine what is the correct excitation sign
    exc_factor = str2num([exc_sign, '1']);
    if exc_dir ~= 'Z'
      exc_factor = exc_factor*(-1);
    end

    % Then: loop through the nine measurements and store them at the correct location
    for j = 2:10
      % Determine what is the accelerometer and direction
      [indices_acc_i] = strfind(meas.(sprintf('FFT1_H1_%i_1_RpName', j)), '.');
      acc_i = str2num(meas.(sprintf('FFT1_H1_%i_1_RpName', j))(indices_acc_i(1)+1:indices_acc_i(2)-1));

      meas_dir  = meas.(sprintf('FFT1_H1_%i_1_RpName', j))(end);
      meas_sign = meas.(sprintf('FFT1_H1_%i_1_RpName', j))(end-1);
      % Determine what is the correct measurement sign
      meas_factor = str2num([meas_sign, '1']);
      if meas_dir ~= 'Z'
        meas_factor = meas_factor*(-1);
      end

      FRFs(find(dirs==meas_dir)+3*(acc_i-1), find(dirs==exc_dir), :) = exc_factor*meas_factor*meas.(sprintf('FFT1_H1_%i_1_Y_ReIm', j));
      COHs(find(dirs==meas_dir)+3*(acc_i-1), find(dirs==exc_dir), :) = meas.(sprintf('FFT1_Coh_%i_1_RMS_Y_Val', j));
    end
  end
  freqs = meas.FFT1_Coh_10_1_RMS_X_Val;

And we save the obtained FRF matrix and Coherence matrix in a .mat file.

  save('./mat/frf_coh_matrices.mat', 'FRFs', 'COHs', 'freqs');

Plot showing the coherence of all the measurements

Now that we have defined a Coherence matrix, we can plot each of its elements to have an idea of the overall coherence and thus, quality of the measurement. The result is shown on figure fig:all_coherence.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/all_coherence.png
Plot of the coherence of all the measurements

Solid Bodies considered for further analysis

We consider the following solid bodies for further analysis:

  • Bottom Granite
  • Top Granite
  • Translation Stage
  • Tilt Stage
  • Spindle
  • Hexapod

We create a matlab structure solids that contains the accelerometers ID connected to each solid bodies (as shown on figure fig:nass-modal-test).

  solids = {};
  solids.gbot = [17, 18, 19, 20];
  solids.gtop = [13, 14, 15, 16];
  solids.ty   = [9, 10, 11, 12];
  solids.ry   = [5, 6, 7, 8];
  solids.rz   = [21, 22, 23];
  solids.hexa = [1, 2, 3, 4];

  solid_names = fields(solids);

Finally, we save that into a .mat file.

  save('mat/geometry.mat', 'solids', 'solid_names', 'acc_pos');

Note about the solid body assumption

If we measure the motion of a rigid body along a direction $\vec{x}$ using 2 sensors that are co-linear with the same direction $\vec{x}$ ($\vec{p}_2 = \vec{p}_1 + \alpha \vec{x}$), they will measured the same quantity.

This is illustrated on figure fig:aligned_accelerometers.

/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/aligned_accelerometers.png

Aligned measurement of the motion of a solid body

The motion of the rigid body of figure fig:aligned_accelerometers is defined by its displacement $\delta p$ and rotation $\vec{\Omega}$ with respect to the reference frame $\{O\}$.

The motions at points $1$ and $2$ are:

\begin{align*} \delta p_1 &= \delta p + \Omega \times p_1 \\ \delta p_2 &= \delta p + \Omega \times p_2 \end{align*}

Taking only the $x$ direction:

\begin{align*} \delta p_{x1} &= \delta p_x + \Omega_y p_{z1} - \Omega_z p_{y1} \\ \delta p_{x2} &= \delta p_x + \Omega_y p_{z2} - \Omega_z p_{y2} \end{align*}

However, we have $p_{1y} = p_{2y}$ and $p_{1z} = p_{2z}$ because of the co-linearity of the two sensors in the $x$ direction, and thus we obtain

\begin{equation} \delta p_{x1} = \delta p_{x2} \end{equation}

Two sensors that are measuring the motion of a rigid body in the direction of the line linking the two sensors should measure the same quantity.

We can verify that the rigid body assumption is correct by comparing the measurement of the sensors.

From the table tab:position_accelerometers, we can guess which sensors will give the same results in the X and Y directions.

Comparison of such measurements in the X direction is shown on figure fig:compare_acc_x_dir and in the Y direction on figure fig:compare_acc_y_dir.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/compare_acc_x_dir.png
Compare accelerometers align in the X direction
  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/compare_acc_y_dir.png
Compare accelerometers align in the Y direction

From the two figures above, we are more confident about the rigid body assumption in the frequency band of interest.

Verification of the principle of reciprocity

Because we expect our system to follow the principle of reciprocity. That is to say the response $X_j$ at some degree of freedom $j$ due to a force $F_k$ applied on DOF $k$ should be the same as the response $X_k$ due to a force $F_j$: \[ H_{jk} = \frac{X_j}{F_k} = \frac{X_k}{F_j} = H_{kj} \]

This comes from the fact that we expect to have symmetric mass, stiffness and damping matrices.

In order to access the quality of the data and the validity of the measured FRF, we then check that the reciprocity between $H_{jk}$ and $H_{kj}$ is of an acceptable level.

We can verify this reciprocity using 3 different pairs of response/force.

  <<plt-matlab>>
/tdehaeze/nass-micro-station-measurements/media/commit/f3bdb7bcf10c31fab849fde4d3c93250d63406e7/modal-analysis/figs/principle_reciprocity.png
Verification of the principle of reciprocity

From figure fig:principle_reciprocity, it seems that the principle of reciprocity is valid from 50Hz to 100Hz. Above that, the difference between the two could be due to:

  • rotational DOFs? Local flexibility?

Below, it could be due to:

  • not exciting and measuring the same DOF

One should note here that the excitation is not applied on the same DOF as the measured response. This could be seen on figures fig:hammer_x, fig:hammer_y and fig:hammer_z that show the excitation points, and on figure fig:accelerometers_ty_overview where the accelerometer on the bottom left shows the one used for the principle of reciprocity validation above. Thus, technically we cannot verify the principle of reciprocity here.

As it is usually very important to measure point response $\frac{X_j}{F_j}$, that is to say exciting and measuring the same DOF, should the measurements be redone? On the modal software that is used to extract modal parameters, it is suppose that we are exciting the exact same DOF as the one measured by the accelerometer 11. As is it not the case in practice, could this induce large errors in the modal model?

Bibliography   ignore

bibliographystyle:unsrt bibliography:ref.bib