nass-micro-station-measurem.../disturbance-measurement
2019-05-14 10:22:57 +02:00
..
mat Renamed one folder. Add analysis of vibrations when rotating 2019-05-14 10:22:57 +02:00
disturbance_measurement.slx add measurements 2019-04-30 17:15:53 +02:00
index.html Update index.org 2019-05-02 14:12:11 +02:00
index.org Reworked the ground motion page 2019-05-10 17:52:14 +02:00
readme.org add measurements spindle + dynamics 2019-05-10 16:11:49 +02:00
run_test.m Add measurements: LPF, noise induced by all the stages 2019-05-07 10:43:26 +02:00
setup.m add spindle disturbance measurements 2019-04-30 11:40:38 +02:00

#+TITLE:Measurement of the sample vibrations when rotating the Spindle

Measurement:

  • one geophone on the marble
  • one geophone at the sample position

Every stage is powered on.

Data file Description
data_001.mat nothing is turning
data_002.mat spindle is turning at 1rpm

Mesures Dynamiques Rotation Slip-Ring

All the stages are OFF

One geophone on the marble (Col 1) One geophone at the sample location (Col 2)

Voltage amplifier setup: 60dB AC 1kHz

LPF added at the input of the voltage amplifiers

Goal:

  • Identifify the vibration induced by the rotation of the Slip-Ring and Spindle
  • meas24: All OFF
  • meas25: 6RPM: only the slip-ring is ON and rotating (spindle OFF)
  • meas26: 6RPMZ; Slip-ring and Spindle ON