103 lines
2.0 KiB
Org Mode
103 lines
2.0 KiB
Org Mode
#+TITLE: Measurements
|
|
|
|
* DONE Measurement of the slip-ring noise when turning
|
|
CLOSED: [2019-05-14 mar. 10:36]
|
|
|
|
Voltage amplifier:
|
|
- 60db
|
|
- AC
|
|
- 1kHz
|
|
|
|
Additionnal LPF at 1kHz
|
|
|
|
- meas30: All off
|
|
- meas31: Slip-ring on
|
|
- meas32: slip-ring 6rpm
|
|
- meas33: slip-ring 60rpm
|
|
|
|
Channel 1: direct
|
|
Channel 2: slip-ring
|
|
|
|
* DONE Measuremeent of the noise of the slip-ring when turned ON using geophones
|
|
CLOSED: [2019-05-14 mar. 10:36]
|
|
|
|
Voltage amplifier:
|
|
- 60db
|
|
- AC
|
|
- 1kHz
|
|
|
|
Additionnal LPF at 1kHz
|
|
|
|
- meas35: All off
|
|
- meas36: slip-ring ON
|
|
|
|
geophone at the sample location
|
|
slit into 2 BNC:
|
|
- first one (column one): direct wire
|
|
- second one (second column): slip-ring wire
|
|
|
|
Each of the signal is amplified by voltage amplifier:
|
|
- 60db
|
|
- AC
|
|
- 1kHz
|
|
|
|
Additionnal LPF is added before the voltage amplifiers
|
|
|
|
* DONE Measure of the ground and marble velocity
|
|
CLOSED: [2019-05-14 mar. 10:34]
|
|
|
|
One geophone is located on the marble, the other one on the floor.
|
|
|
|
col1: floor
|
|
col2: marble
|
|
|
|
Each of the signal is amplified by voltage amplifier:
|
|
- 60db
|
|
- AC
|
|
- 1kHz
|
|
|
|
- meas 37: Z direction
|
|
- meas 38: N direction
|
|
- meas 39: E direction
|
|
|
|
* DONE Measure of the vibration when rotating the Slip-ring and Ty
|
|
CLOSED: [2019-05-14 mar. 10:39]
|
|
|
|
All the stages are OFF except Ty and Slip-Ring.
|
|
|
|
Each of the signal is amplified by voltage amplifier:
|
|
- 40db!!!
|
|
- AC
|
|
- 1kHz
|
|
|
|
col1: marble
|
|
col2: sample
|
|
|
|
Rotating the slip-ring at 60rpm and scans with the Ty at 1Hz.
|
|
Everything on the Z direction
|
|
|
|
- meas 50: Slip-Ring at 1Hz, Ty OFF
|
|
- meas 51: Slip-Ring at 1Hz, Ty ON (The current and cnt error of Ty is also registered)
|
|
- meas 52: Slip-Ring at 1Hz, Ty 1Hz 600000cnt
|
|
|
|
* DONE Measure of the vibration induced by Ty motion
|
|
CLOSED: [2019-05-14 mar. 10:42]
|
|
|
|
One geophone at the sample position
|
|
One geophone on the marble
|
|
|
|
Each of the signal is amplified by voltage amplifier:
|
|
- 40db!!!
|
|
- AC
|
|
- 1kHz
|
|
|
|
col1: marble
|
|
col2: sample
|
|
|
|
Ty Scans:
|
|
- sin @ 1Hz with amplitude = 600 000 cnt (= 3mm)
|
|
|
|
- meas 40: Z direction
|
|
- meas 41: E direction
|
|
- meas 42: E direction without any motion (Ty OFF)
|