nass-micro-station-measurem.../disturbance-ty-sr/index.org

1.6 KiB

#+TITLE:Vibrations induced by both the translation stage and the slip-ring

Measurement description

All the stages are OFF except Ty and Slip-Ring.

Each of the signal is amplified by voltage amplifier:

  • 40db!!!
  • AC
  • 1kHz

col1: marble col2: sample

Rotating the slip-ring at 60rpm and scans with the Ty at 1Hz. Everything on the Z direction

  • meas 50: Slip-Ring at 1Hz, Ty OFF
  • meas 51: Slip-Ring at 1Hz, Ty ON (The current and cnt error of Ty is also registered)
  • meas 52: Slip-Ring at 1Hz, Ty 1Hz 600000cnt