digital-brain/public/zettels/position_sensors/index.html
2020-06-03 22:43:54 +02:00

552 lines
17 KiB
HTML
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

<!DOCTYPE html>
<html lang="en">
<head>
<meta charset="utf-8">
<meta http-equiv="X-UA-Compatible" content="IE=edge,chrome=1">
<title>Position Sensors - My digital brain</title>
<meta name="renderer" content="webkit" />
<meta name="viewport" content="width=device-width, initial-scale=1, maximum-scale=1"/>
<meta http-equiv="Cache-Control" content="no-transform" />
<meta http-equiv="Cache-Control" content="no-siteapp" />
<meta name="theme-color" content="#f8f5ec" />
<meta name="msapplication-navbutton-color" content="#f8f5ec">
<meta name="apple-mobile-web-app-capable" content="yes">
<meta name="apple-mobile-web-app-status-bar-style" content="#f8f5ec">
<meta name="author" content="
&mdash;
Thomas Dehaeze
" /><meta name="description" content="Tags Inertial Sensors Reviews of position sensors (Collette {\it et al.}, 2012) Fleming, A. J., A review of nanometer resolution position sensors: operation and performance (Andrew Fleming, 2013) (Notes) Relative Position Sensors
Table 1: Characteristics of relative measurement sensors collette11_review Technology Frequency Resolution Range T Range LVDT DC-200 Hz 10 nm rms 1-10 mm -50,100 °C Eddy current 5 kHz 0." />
<link rel="canonical" href="/zettels/position_sensors/" />
<link rel="icon" type="image/png" sizes="32x32" href="/favicon-32x32.png">
<link rel="icon" type="image/png" sizes="16x16" href="/favicon-16x16.png">
<link href="/sass/main.min.47a894bd6354cc46903f62433747958dc936e1c95c28a76ac80319bca9708ed1.css" rel="stylesheet">
</head>
<body>
<div id="mobile-navbar" class="mobile-navbar">
<div class="mobile-header-logo">
<a href="/" class="logo">Digital Brain</a>
</div>
<div class="mobile-navbar-icon">
<span></span>
<span></span>
<span></span>
</div>
</div>
<nav id="mobile-menu" class="mobile-menu slideout-menu">
<ul class="mobile-menu-list">
<a href="/">
<li class="mobile-menu-item">Home</li>
</a><a href="/zettels/">
<li class="mobile-menu-item">Zettels</li>
</a><a href="/book/">
<li class="mobile-menu-item">Books</li>
</a><a href="/paper/">
<li class="mobile-menu-item">Papers</li>
</a><a href="/search/">
<li class="mobile-menu-item">Search</li>
</a>
</ul>
</nav>
<div class="container" id="mobile-panel">
<header id="header" class="header">
<div class="logo-wrapper">
<a href="/" class="logo">Digital Brain</a>
</div>
<nav class="site-navbar">
<ul id="menu" class="menu">
<li class="menu-item">
<a class="menu-item-link" href="/">Home</a>
</li><li class="menu-item">
<a class="menu-item-link" href="/zettels/">Zettels</a>
</li><li class="menu-item">
<a class="menu-item-link" href="/book/">Books</a>
</li><li class="menu-item">
<a class="menu-item-link" href="/paper/">Papers</a>
</li><li class="menu-item">
<a class="menu-item-link" href="/search/">Search</a>
</li>
</ul>
</nav>
</header>
<main id="main" class="main">
<div class="content-wrapper">
<div id="content" class="content">
<article class="post">
<header class="post-header">
<h1 class="post-title">Position Sensors</h1>
</header>
<div class="post-toc" id="post-toc">
<h2 class="post-toc-title">Contents</h2>
<div class="post-toc-content">
<nav id="TableOfContents">
<ul>
<li><a href="#reviews-of-position-sensors">Reviews of position sensors</a></li>
<li><a href="#relative-position-sensors">Relative Position Sensors</a>
<ul>
<li><a href="#strain-gauge">Strain Gauge</a></li>
<li><a href="#capacitive-sensor">Capacitive Sensor</a></li>
<li><a href="#inductive-sensor--eddy-current">Inductive Sensor (Eddy Current)</a></li>
<li><a href="#inductive-sensor--lvdt">Inductive Sensor (LVDT)</a></li>
<li><a href="#interferometers">Interferometers</a></li>
<li><a href="#fiber-optic-displacement-sensor">Fiber Optic Displacement Sensor</a></li>
</ul>
</li>
</ul>
<ul>
<li><a href="#backlinks">Backlinks</a></li>
</ul>
</nav>
</div>
</div>
<div class="post-content">
<dl>
<dt>Tags</dt>
<dd><a href="/zettels/inertial_sensors/">Inertial Sensors</a></dd>
</dl>
<h2 id="reviews-of-position-sensors">Reviews of position sensors</h2>
<ul>
<li><sup id="0b0b67de6dddc4d28031ab2d3b28cd3d"><a href="#collette12_compar" title="Collette, Janssens, Mokrani, Fueyo-Roza, L, Artoos, Esposito, Fernandez-Carmona, , Guinchard \&amp; Leuxe, Comparison of new absolute displacement sensors, in in: {International Conference on Noise and Vibration Engineering
(ISMA)}, edited by (2012)">(Collette {\it et al.}, 2012)</a></sup></li>
<li>Fleming, A. J., A review of nanometer resolution position sensors: operation and performance <sup id="3fb5b61524290e36d639a4fac65703d0"><a href="#fleming13_review_nanom_resol_posit_sensor" title="Andrew Fleming, A Review of Nanometer Resolution Position Sensors: Operation and Performance, {Sensors and Actuators A: Physical}, v(nil), 106-126 (2013).">(Andrew Fleming, 2013)</a></sup> (<a href="/paper/fleming13_review_nanom_resol_posit_sensor/">Notes</a>)</li>
</ul>
<h2 id="relative-position-sensors">Relative Position Sensors</h2>
<p><a id="table--tab:characteristics-relative-sensor"></a></p>
<div class="table-caption">
<span class="table-number"><a href="#table--tab:characteristics-relative-sensor">Table 1</a></span>:
Characteristics of relative measurement sensors <a class='org-ref-reference' href="#collette11_review">collette11_review</a>
</div>
<table>
<thead>
<tr>
<th>Technology</th>
<th>Frequency</th>
<th>Resolution</th>
<th>Range</th>
<th>T Range</th>
</tr>
</thead>
<tbody>
<tr>
<td>LVDT</td>
<td>DC-200 Hz</td>
<td>10 nm rms</td>
<td>1-10 mm</td>
<td>-50,100 °C</td>
</tr>
<tr>
<td>Eddy current</td>
<td>5 kHz</td>
<td>0.1-100 nm rms</td>
<td>0.5-55 mm</td>
<td>-50,100 °C</td>
</tr>
<tr>
<td>Capacitive</td>
<td>DC-100 kHz</td>
<td>0.05-50 nm rms</td>
<td>50 nm - 1 cm</td>
<td>-40,100 °C</td>
</tr>
<tr>
<td>Interferometer</td>
<td>300 kHz</td>
<td>0.1 nm rms</td>
<td>10 cm</td>
<td>-250,100 °C</td>
</tr>
<tr>
<td>Encoder</td>
<td>DC-1 MHz</td>
<td>1 nm rms</td>
<td>7-27 mm</td>
<td>0,40 °C</td>
</tr>
<tr>
<td>Bragg Fibers</td>
<td>DC-150 Hz</td>
<td>0.3 nm rms</td>
<td>3.5 cm</td>
<td>-30,80 °C</td>
</tr>
</tbody>
</table>
<p><a id="table--tab:summary-position-sensors"></a></p>
<div class="table-caption">
<span class="table-number"><a href="#table--tab:summary-position-sensors">Table 2</a></span>:
Summary of position sensor characteristics. The dynamic range (DNR) and resolution are approximations based on a full-scale range of \(100 \mu m\) and a first order bandwidth of \(1 kHz\) <a class='org-ref-reference' href="#fleming13_review_nanom_resol_posit_sensor">fleming13_review_nanom_resol_posit_sensor</a>
</div>
<table>
<thead>
<tr>
<th>Sensor Type</th>
<th>Range</th>
<th>DNR</th>
<th>Resolution</th>
<th>Max. BW</th>
<th>Accuracy</th>
</tr>
</thead>
<tbody>
<tr>
<td>Metal foil</td>
<td>\(10-500 \mu m\)</td>
<td>230 ppm</td>
<td>23 nm</td>
<td>1-10 kHz</td>
<td>1% FSR</td>
</tr>
<tr>
<td>Piezoresistive</td>
<td>\(1-500 \mu m\)</td>
<td>5 ppm</td>
<td>0.5 nm</td>
<td>&gt;100 kHz</td>
<td>1% FSR</td>
</tr>
<tr>
<td>Capacitive</td>
<td>\(10 \mu m\) to \(10 mm\)</td>
<td>24 ppm</td>
<td>2.4 nm</td>
<td>100 kHz</td>
<td>0.1% FSR</td>
</tr>
<tr>
<td>Electrothermal</td>
<td>\(10 \mu m\) to \(1 mm\)</td>
<td>100 ppm</td>
<td>10 nm</td>
<td>10 kHz</td>
<td>1% FSR</td>
</tr>
<tr>
<td>Eddy current</td>
<td>\(100 \mu m\) to \(80 mm\)</td>
<td>10 ppm</td>
<td>1 nm</td>
<td>40 kHz</td>
<td>0.1% FSR</td>
</tr>
<tr>
<td>LVDT</td>
<td>\(0.5-500 mm\)</td>
<td>10 ppm</td>
<td>5 nm</td>
<td>1 kHz</td>
<td>0.25% FSR</td>
</tr>
<tr>
<td>Interferometer</td>
<td>Meters</td>
<td></td>
<td>0.5 nm</td>
<td>&gt;100kHz</td>
<td>1 ppm FSR</td>
</tr>
<tr>
<td>Encoder</td>
<td>Meters</td>
<td></td>
<td>6 nm</td>
<td>&gt;100kHz</td>
<td>5 ppm FSR</td>
</tr>
</tbody>
</table>
<h3 id="strain-gauge">Strain Gauge</h3>
<h3 id="capacitive-sensor">Capacitive Sensor</h3>
<p>Description:</p>
<ul>
<li><a href="http://www.lionprecision.com/tech-library/technotes/cap-0020-sensor-theory.html">http://www.lionprecision.com/tech-library/technotes/cap-0020-sensor-theory.html</a></li>
<li><a href="https://www.lionprecision.com/comparing-capacitive-and-eddy-current-sensors">https://www.lionprecision.com/comparing-capacitive-and-eddy-current-sensors</a></li>
</ul>
<table>
<thead>
<tr>
<th></th>
<th></th>
</tr>
</thead>
<tbody>
<tr>
<td>Micro Sense</td>
<td><a href="http://www.microsense.net/products-position-sensors.htm">link</a></td>
</tr>
<tr>
<td>Micro-Epsilon</td>
<td><a href="https://www.micro-epsilon.com/displacement-position-sensors/capacitive-sensor/">link</a></td>
</tr>
<tr>
<td>PI</td>
<td><a href="https://www.physikinstrumente.com/en/technology/sensor-technologies/capacitive-sensors/">link</a></td>
</tr>
<tr>
<td>Unipulse</td>
<td><a href="https://www.unipulse.com/product/ps-ia/">link</a></td>
</tr>
<tr>
<td>Lion-Precision</td>
<td><a href="https://www.lionprecision.com/products/capacitive-sensors">link</a></td>
</tr>
</tbody>
</table>
<h3 id="inductive-sensor--eddy-current">Inductive Sensor (Eddy Current)</h3>
<table>
<thead>
<tr>
<th></th>
<th></th>
</tr>
</thead>
<tbody>
<tr>
<td>Micro-Epsilon</td>
<td><a href="https://www.micro-epsilon.com/displacement-position-sensors/eddy-current-sensor/">link</a></td>
</tr>
<tr>
<td>Lion Precision</td>
<td><a href="https://www.lionprecision.com/products/eddy-current-sensors">link</a></td>
</tr>
</tbody>
</table>
<h3 id="inductive-sensor--lvdt">Inductive Sensor (LVDT)</h3>
<table>
<thead>
<tr>
<th></th>
<th></th>
</tr>
</thead>
<tbody>
<tr>
<td>Micro-Epsilon</td>
<td><a href="https://www.micro-epsilon.com/displacement-position-sensors/inductive-sensor-lvdt/">link</a></td>
</tr>
<tr>
<td>Keyence</td>
<td><a href="https://www.keyence.eu/products/measure/contact-distance-lvdt/gt2/index.jsp">link</a></td>
</tr>
</tbody>
</table>
<h3 id="interferometers">Interferometers</h3>
<table>
<thead>
<tr>
<th></th>
<th></th>
</tr>
</thead>
<tbody>
<tr>
<td>Attocube</td>
<td><a href="http://www.attocube.com/">link</a></td>
</tr>
<tr>
<td>Zygo</td>
<td><a href="https://www.zygo.com/?/met/markets/stageposition/zmi/">link</a></td>
</tr>
<tr>
<td>Smaract</td>
<td><a href="https://www.smaract.com/interferometry">link</a></td>
</tr>
<tr>
<td>Qutools</td>
<td><a href="https://www.qutools.com/qudis/">link</a></td>
</tr>
<tr>
<td>Renishaw</td>
<td><a href="https://www.renishaw.com/en/fibre-optic-laser-encoder-products--6594">link</a></td>
</tr>
<tr>
<td>Sios</td>
<td><a href="https://sios-de.com/products/length-measurement/laser-interferometer/">link</a></td>
</tr>
<tr>
<td>Keysight</td>
<td><a href="https://www.keysight.com/en/pc-1000000393%3Aepsg%3Apgr/laser-heads?nid=-536900395.0&amp;cc=FR&amp;lc=fre">link</a></td>
</tr>
</tbody>
</table>
<div class="table-caption">
<span class="table-number">Table 3</span>:
Characteristics of Environmental Units
</div>
<table>
<thead>
<tr>
<th></th>
<th>Temperature (\(\pm\ ^oC\))</th>
<th>Pressure (\(\pm\ hPa\))</th>
<th>Humidity \(\pm\% RH\)</th>
<th>Wavelength Accuracy (\(\pm\ \text{ppm}\))</th>
</tr>
</thead>
<tbody>
<tr>
<td>Attocube</td>
<td>0.1</td>
<td>1</td>
<td>2</td>
<td>0.5</td>
</tr>
<tr>
<td>Renishaw</td>
<td>0.2</td>
<td>1</td>
<td>6</td>
<td>1</td>
</tr>
<tr>
<td>Picoscale</td>
<td>0.2</td>
<td>2</td>
<td>2</td>
<td>1</td>
</tr>
</tbody>
</table>
<p><sup id="7658b1219a4458a62ae8c6f51b767542"><a href="#jang17_compen_refrac_index_air_laser" title="Yoon-Soo Jang \&amp; Seung-Woo Kim, Compensation of the Refractive Index of Air in Laser Interferometer for Distance Measurement: a Review, {International Journal of Precision Engineering and
Manufacturing}, v(12), 1881-1890 (2017).">(Yoon-Soo Jang &amp; Seung-Woo Kim, 2017)</a></sup></p>
<p><a id="orge1e204f"></a></p>
<figure>
<img src="/ox-hugo/position_sensor_interferometer_precision.png"
alt="Figure 1: Expected precision of interferometer as a function of measured distance"/> <figcaption>
<p>Figure 1: Expected precision of interferometer as a function of measured distance</p>
</figcaption>
</figure>
<h3 id="fiber-optic-displacement-sensor">Fiber Optic Displacement Sensor</h3>
<table>
<thead>
<tr>
<th></th>
<th></th>
</tr>
</thead>
<tbody>
<tr>
<td>Unipulse</td>
<td><a href="https://www.unipulse.com/product/atw200-2/">link</a></td>
</tr>
</tbody>
</table>
<h1 id="bibliography">Bibliography</h1>
<p><a id="collette12_compar"></a>Collette, C., Janssens, S., Mokrani, B., Fueyo-Roza, L., Artoos, K., Esposito, M., Fernandez-Carmona, P., …, <em>Comparison of new absolute displacement sensors</em>, In , International Conference on Noise and Vibration Engineering (ISMA) (pp. ) (2012). : . <a href="#0b0b67de6dddc4d28031ab2d3b28cd3d"></a></p>
<p><a id="fleming13_review_nanom_resol_posit_sensor"></a>Fleming, A. J., <em>A review of nanometer resolution position sensors: operation and performance</em>, Sensors and Actuators A: Physical, <em>190(nil)</em>, 106126 (2013). <a href="http://dx.doi.org/10.1016/j.sna.2012.10.016">http://dx.doi.org/10.1016/j.sna.2012.10.016</a> <a href="#3fb5b61524290e36d639a4fac65703d0"></a></p>
<p><a id="collette11_review"></a>Collette, C., Artoos, K., Guinchard, M., Janssens, S., Carmona Fernandez, P., &amp; Hauviller, C., <em>Review of sensors for low frequency seismic vibration measurement</em> (2011). <a href="#642a18d86de4e062c6afb0f5f20501c4"></a></p>
<p><a id="jang17_compen_refrac_index_air_laser"></a>Jang, Y., &amp; Kim, S., <em>Compensation of the refractive index of air in laser interferometer for distance measurement: a review</em>, International Journal of Precision Engineering and Manufacturing, <em>18(12)</em>, 18811890 (2017). <a href="http://dx.doi.org/10.1007/s12541-017-0217-y">http://dx.doi.org/10.1007/s12541-017-0217-y</a> <a href="#7658b1219a4458a62ae8c6f51b767542"></a></p>
<h2 id="backlinks">Backlinks</h2>
<ul>
<li><a href="/paper/gao15_measur_techn_precis_posit/">Measurement technologies for precision positioning</a></li>
<li><a href="/paper/fleming13_review_nanom_resol_posit_sensor/">A review of nanometer resolution position sensors: operation and performance</a></li>
</ul>
</div>
<footer class="post-footer">
<nav class="post-nav">
<a class="prev" href="/zettels/nano_active_stabilization_system/">
<i class="iconfont icon-left"></i>
<span class="prev-text nav-default">Nano Active Stabilization System</span>
<span class="prev-text nav-mobile">Prev</span>
</a>
<a class="next" href="/zettels/positioning_stations/">
<span class="next-text nav-default">Positioning Stations</span>
<span class="next-text nav-mobile">Next</span>
<i class="iconfont icon-right"></i>
</a>
</nav>
</footer>
</article>
</div>
</div>
</main>
<footer id="footer" class="footer">
<div class="social-links">
<a href="mailto:dehaeze.thomas@gmail.com" class="iconfont icon-email" title="email"></a>
<a href="https://github.com/tdehaeze/" class="iconfont icon-github" title="github"></a>
<a href="/index.xml" type="application/rss+xml" class="iconfont icon-rss" title="rss"></a>
</div>
<div class="copyright">
<span class="power-by">
Powered by <a class="hexo-link" href="https://gohugo.io">Hugo</a>
</span>
<span class="copyright-year">
&copy;
2020
<span class="heart">
<i class="iconfont icon-heart"></i>
</span>
<span class="author">Thomas Dehaeze</span>
</span>
</div>
</footer>
<div class="back-to-top" id="back-to-top">
<i class="iconfont icon-up"></i>
</div>
</div>
<script src="https://cdn.jsdelivr.net/npm/jquery@3.2.1/dist/jquery.min.js" integrity="sha256-hwg4gsxgFZhOsEEamdOYGBf13FyQuiTwlAQgxVSNgt4=" crossorigin="anonymous"></script>
<script src="https://cdn.jsdelivr.net/npm/slideout@1.0.1/dist/slideout.min.js" integrity="sha256-t+zJ/g8/KXIJMjSVQdnibt4dlaDxc9zXr/9oNPeWqdg=" crossorigin="anonymous"></script>
<script type="text/javascript" src="/js/main.4bada4f824623eea2eb7cfd5cf8c1d99c3dd797297e7e8cbc59a41da450bb334.js"></script>
<script type="text/javascript">
window.MathJax = {
loader: {
load: ['[tex]/ams']
},
tex: {
inlineMath: [
['$','$'], ['\\(','\\)']
],
tags: 'ams',
packages: {'[+]': ['ams']},
}
};
</script>
<script async src="https://cdn.jsdelivr.net/npm/mathjax@3/es5/tex-mml-chtml.js" crossorigin="anonymous"></script>
<script src="https://cdnjs.cloudflare.com/ajax/libs/fuse.js/3.2.0/fuse.min.js"></script>
<script src="https://cdnjs.cloudflare.com/ajax/libs/mark.js/8.11.1/jquery.mark.min.js"></script>
<script type="text/javascript" src="/lib/search/search.js"></script>
</body>
</html>