Compare commits

...

2 Commits

Author SHA1 Message Date
5e91fe033b Update Content - 2023-11-22 2023-11-22 13:56:17 +01:00
b3e9b8c09d Update Content - 2023-11-12 2023-11-12 17:37:13 +01:00
2 changed files with 9 additions and 4 deletions

View File

@ -35,10 +35,10 @@ Tags
| | RMS noise | Noise Density (%/Hz^.5) | Linearity |
|----------------------|---------------------|-------------------------|-----------|
| Fogale MC900 | < 0.005% (10kHz) | 0.00005 | <0.2% |
| micro-epsilon DL6230 | 0.005% (5kHz) | 0.00007 | 0.05% |
| Fogale MC900 | < 0.005% (10kHz) | 0.000050 | <0.2% |
| Micro-Epsilon DL6230 | 0.005% (5kHz) | 0.000070 | 0.05% |
| Lion CPL290 | 0.003% (15kHz) | 0.000025 | <0.2% |
| PI | | | |
| PI | 0.002% (3kHz) | 0.000036 | <0.1 |
## Bibliography {#bibliography}

View File

@ -1,5 +1,5 @@
+++
title = "Torque Motor"
title = "Torque Motor (3-phase)"
author = ["Dehaeze Thomas"]
draft = false
+++
@ -10,6 +10,11 @@ Tags
Nice tutorial: <https://www.youtube.com/watch?v=3XcvjC2anM8&list=PLmklAQtFT_ZKcaI21UHgi0cm2Y3Yxu90p&index=3>
## Error period for 3-phase motors {#error-period-for-3-phase-motors}
Due to cogging, the fundamental period of the error is: number of pair poles \* 3 (because 3-phases).
## Manufacturers {#manufacturers}
| Manufacturers | Country |