Update Content - 2022-03-15
This commit is contained in:
@@ -1,17 +1,17 @@
|
||||
+++
|
||||
title = "An instrument for 3d x-ray nano-imaging"
|
||||
author = ["Thomas Dehaeze"]
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
: [Nano Active Stabilization System]({{< relref "nano_active_stabilization_system" >}}), [Positioning Stations]({{< relref "positioning_stations" >}})
|
||||
: [Nano Active Stabilization System]({{< relref "nano_active_stabilization_system.md" >}}), [Positioning Stations]({{< relref "positioning_stations.md" >}})
|
||||
|
||||
Reference
|
||||
: ([Holler et al. 2012](#orgacde90c))
|
||||
: (<a href="#citeproc_bib_item_1">Holler et al. 2012</a>)
|
||||
|
||||
Author(s)
|
||||
: Holler, M., Raabe, J., Diaz, A., Guizar-Sicairos, M., Quitmann, C., Menzel, A., & Bunk, O.
|
||||
: Holler, M., Raabe, J., Diaz, A., Guizar-Sicairos, M., Quitmann, C., Menzel, A., & Bunk, O.
|
||||
|
||||
Year
|
||||
: 2012
|
||||
@@ -19,9 +19,9 @@ Year
|
||||
Instrument similar to the NASS.
|
||||
Obtain position stability of 10nm (standard deviation).
|
||||
|
||||
<a id="org03c494c"></a>
|
||||
<a id="figure--fig:holler12-station"></a>
|
||||
|
||||
{{< figure src="/ox-hugo/holler12_station.png" caption="Figure 1: Schematic of the tomography setup" >}}
|
||||
{{< figure src="/ox-hugo/holler12_station.png" caption="<span class=\"figure-number\">Figure 1: </span>Schematic of the tomography setup" >}}
|
||||
|
||||
- **Limited resolution due to instrumentation**:
|
||||
The resolution of ptychographic tomography remains above 100nm due to instabilities and drifts of the scanning systems.
|
||||
@@ -39,7 +39,8 @@ Obtain position stability of 10nm (standard deviation).
|
||||
- **Feedback Loop**: Using the signals from the 2 interferometers, the loop is closed to compensate low frequency vibrations and thermal drifts.
|
||||
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
<a id="orgacde90c"></a>Holler, M., J. Raabe, A. Diaz, M. Guizar-Sicairos, C. Quitmann, A. Menzel, and O. Bunk. 2012. “An Instrument for 3d X-Ray Nano-Imaging.” _Review of Scientific Instruments_ 83 (7):073703. <https://doi.org/10.1063/1.4737624>.
|
||||
<style>.csl-entry{text-indent: -1.5em; margin-left: 1.5em;}</style><div class="csl-bib-body">
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_1"></a>Holler, M., J. Raabe, A. Diaz, M. Guizar-Sicairos, C. Quitmann, A. Menzel, and O. Bunk. 2012. “An Instrument for 3d X-Ray Nano-Imaging.” <i>Review of Scientific Instruments</i> 83 (7): 073703. doi:<a href="https://doi.org/10.1063/1.4737624">10.1063/1.4737624</a>.</div>
|
||||
</div>
|
||||
|
Reference in New Issue
Block a user