2020-04-20 18:58:10 +02:00
|
|
|
|
+++
|
|
|
|
|
title = "Nanometre-cutting machine using a stewart-platform parallel mechanism"
|
|
|
|
|
author = ["Thomas Dehaeze"]
|
|
|
|
|
draft = false
|
|
|
|
|
+++
|
|
|
|
|
|
|
|
|
|
Tags
|
|
|
|
|
: [Stewart Platforms]({{< relref "stewart_platforms" >}}), [Flexible Joints]({{< relref "flexible_joints" >}})
|
|
|
|
|
|
|
|
|
|
Reference
|
2021-05-02 22:18:30 +02:00
|
|
|
|
: ([Furutani, Suzuki, and Kudoh 2004](#org9d14335))
|
2020-04-20 18:58:10 +02:00
|
|
|
|
|
|
|
|
|
Author(s)
|
|
|
|
|
: Furutani, K., Suzuki, M., & Kudoh, R.
|
|
|
|
|
|
|
|
|
|
Year
|
|
|
|
|
: 2004
|
|
|
|
|
|
|
|
|
|
- Lever mechanism to amplify the motion of piezoelectric stack actuators
|
|
|
|
|
- Use of flexure joints
|
|
|
|
|
- Eddy current displacement sensors for control (decentralized)
|
|
|
|
|
|
|
|
|
|
{{< figure src="/ox-hugo/furutani04_ctrl_arch.png" >}}
|
|
|
|
|
|
|
|
|
|
- Isotropic performance (cubic configuration even if not said so)
|
|
|
|
|
|
|
|
|
|
Possible sources of error:
|
|
|
|
|
|
|
|
|
|
- position error of the link ends in assembly => simulation of position error and it is not significant
|
|
|
|
|
- Inaccurate modelling of the links
|
|
|
|
|
- insufficient generative force
|
|
|
|
|
- unwanted deformation of the links
|
|
|
|
|
|
|
|
|
|
To minimize the errors, a calibration is done between the required leg length and the wanted platform pose.
|
|
|
|
|
Then, it is fitted with 4th order polynomial and included in the control architecture.
|
|
|
|
|
|
2020-08-17 21:59:26 +02:00
|
|
|
|
|
2021-05-02 20:37:00 +02:00
|
|
|
|
|
2020-08-17 21:59:26 +02:00
|
|
|
|
## Bibliography {#bibliography}
|
|
|
|
|
|
2021-05-02 22:18:30 +02:00
|
|
|
|
<a id="org9d14335"></a>Furutani, Katsushi, Michio Suzuki, and Ryusei Kudoh. 2004. “Nanometre-Cutting Machine Using a Stewart-Platform Parallel Mechanism.” _Measurement Science and Technology_ 15 (2):467–74. <https://doi.org/10.1088/0957-0233/15/2/022>.
|