194 lines
6.1 KiB
HTML
194 lines
6.1 KiB
HTML
<?xml version="1.0" encoding="utf-8"?>
|
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN"
|
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
|
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en" xml:lang="en">
|
|
<head>
|
|
<!-- 2020-12-17 jeu. 14:54 -->
|
|
<meta http-equiv="Content-Type" content="text/html;charset=utf-8" />
|
|
<title>Encoder Renishaw Vionic - Test Bench</title>
|
|
<meta name="generator" content="Org mode" />
|
|
<meta name="author" content="Dehaeze Thomas" />
|
|
<link rel="stylesheet" type="text/css" href="https://research.tdehaeze.xyz/css/style.css"/>
|
|
<script type="text/javascript" src="https://research.tdehaeze.xyz/js/script.js"></script>
|
|
<script>MathJax = {
|
|
tex: {
|
|
tags: 'ams',
|
|
macros: {bm: ["\\boldsymbol{#1}",1],}
|
|
}
|
|
};
|
|
</script>
|
|
<script type="text/javascript" src="https://cdn.jsdelivr.net/npm/mathjax@3/es5/tex-mml-chtml.js"></script>
|
|
</head>
|
|
<body>
|
|
<div id="org-div-home-and-up">
|
|
<a accesskey="h" href="../index.html"> UP </a>
|
|
|
|
|
<a accesskey="H" href="../index.html"> HOME </a>
|
|
</div><div id="content">
|
|
<h1 class="title">Encoder Renishaw Vionic - Test Bench</h1>
|
|
<div id="table-of-contents">
|
|
<h2>Table of Contents</h2>
|
|
<div id="text-table-of-contents">
|
|
<ul>
|
|
<li><a href="#org52a1b18">1. Encoder Model</a></li>
|
|
<li><a href="#org79c9cb0">2. Test-Bench Description</a></li>
|
|
<li><a href="#org68a3dfb">3. Measurement procedure</a></li>
|
|
<li><a href="#orgf207a65">4. Measurement Results</a></li>
|
|
</ul>
|
|
</div>
|
|
</div>
|
|
|
|
<div class="note" id="orgf5882b4">
|
|
<p>
|
|
You can find below the document of:
|
|
</p>
|
|
<ul class="org-ul">
|
|
<li><a href="doc/L-9517-9678-05-A_Data_sheet_VIONiC_series_en.pdf">Vionic Encoder</a></li>
|
|
<li><a href="doc/L-9517-9862-01-C_Data_sheet_RKLC_EN.pdf">Linear Scale</a></li>
|
|
</ul>
|
|
|
|
</div>
|
|
|
|
<p>
|
|
We would like to characterize the encoder measurement system.
|
|
</p>
|
|
|
|
<p>
|
|
In particular, we would like to measure:
|
|
</p>
|
|
<ul class="org-ul">
|
|
<li>Power Spectral Density of the measurement noise</li>
|
|
<li>Bandwidth of the sensor</li>
|
|
<li>Linearity of the sensor</li>
|
|
</ul>
|
|
|
|
<div id="outline-container-org52a1b18" class="outline-2">
|
|
<h2 id="org52a1b18"><span class="section-number-2">1</span> Encoder Model</h2>
|
|
<div class="outline-text-2" id="text-1">
|
|
<p>
|
|
The Encoder is characterized by its dynamics \(G_m(s)\) from the “true” displacement \(y\) to measured displacement \(y_m\).
|
|
Ideally, this dynamics is constant over a wide frequency band with very small phase drop.
|
|
</p>
|
|
|
|
<p>
|
|
It is also characterized by its measurement noise \(n\) that can be described by its Power Spectral Density (PSD).
|
|
</p>
|
|
|
|
<p>
|
|
The model of the encoder is shown in Figure <a href="#org131b7a7">1</a>.
|
|
</p>
|
|
|
|
|
|
<div id="org131b7a7" class="figure">
|
|
<p><img src="figs/encoder-model-schematic.png" alt="encoder-model-schematic.png" />
|
|
</p>
|
|
<p><span class="figure-number">Figure 1: </span>Model of the Encoder</p>
|
|
</div>
|
|
|
|
|
|
<table id="org00cec14" border="2" cellspacing="0" cellpadding="6" rules="groups" frame="hsides">
|
|
<caption class="t-above"><span class="table-number">Table 1:</span> Characteristics of the Vionic Encoder</caption>
|
|
|
|
<colgroup>
|
|
<col class="org-left" />
|
|
|
|
<col class="org-left" />
|
|
</colgroup>
|
|
<thead>
|
|
<tr>
|
|
<th scope="col" class="org-left"><b>Characteristics</b></th>
|
|
<th scope="col" class="org-left"><b>Manual</b></th>
|
|
</tr>
|
|
</thead>
|
|
<tbody>
|
|
<tr>
|
|
<td class="org-left">Resolution</td>
|
|
<td class="org-left">2.5nm</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="org-left">Sub-Divisional Error</td>
|
|
<td class="org-left">\(< \pm 15\,nm\)</td>
|
|
</tr>
|
|
|
|
<tr>
|
|
<td class="org-left">Bandwidth</td>
|
|
<td class="org-left">> 50 kHz</td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
|
|
|
|
|
|
<div id="orgd22d423" class="figure">
|
|
<p><img src="./figs/vionic_expected_noise.png" alt="vionic_expected_noise.png" />
|
|
</p>
|
|
<p><span class="figure-number">Figure 2: </span>Expected interpolation errors for the Vionic Encoder</p>
|
|
</div>
|
|
</div>
|
|
</div>
|
|
|
|
|
|
<div id="outline-container-org79c9cb0" class="outline-2">
|
|
<h2 id="org79c9cb0"><span class="section-number-2">2</span> Test-Bench Description</h2>
|
|
<div class="outline-text-2" id="text-2">
|
|
<p>
|
|
To measure the noise \(n\) of the encoder, one can rigidly fix the head and the ruler together such that no motion should be measured.
|
|
Then, the measured signal \(y_m\) corresponds to the noise \(n\).
|
|
</p>
|
|
|
|
<p>
|
|
In order to measure the linearity, we have to compare the measured displacement with a reference sensor with a known linearity.
|
|
An interferometer or capacitive sensor should work fine.
|
|
An actuator should also be there so impose a displacement.
|
|
</p>
|
|
|
|
<p>
|
|
One idea is to use the test-bench shown in Figure <a href="#org1bd058e">3</a>.
|
|
</p>
|
|
|
|
<p>
|
|
The APA300ML is used to excite the mass in a broad bandwidth.
|
|
The motion is measured at the same time by the Vionic Encoder and by an interferometer (most likely an Attocube).
|
|
</p>
|
|
|
|
<p>
|
|
As the interferometer has a very large bandwidth, we should be able to estimate the bandwidth of the encoder is it is less than the Nyquist frequency (~ 5kHz).
|
|
</p>
|
|
|
|
|
|
<div id="org1bd058e" class="figure">
|
|
<p><img src="figs/test_bench_encoder_calibration.png" alt="test_bench_encoder_calibration.png" />
|
|
</p>
|
|
<p><span class="figure-number">Figure 3: </span>Schematic of the test bench</p>
|
|
</div>
|
|
|
|
<p>
|
|
To measure the noise of the sensor, we can also simply measure the output signal when the relative motion between the encoder and the ruler is null.
|
|
This can be done by clamping the two as done in the mounting strut tool (Figure <a href="#orgfdf8d08">4</a>).
|
|
</p>
|
|
|
|
|
|
<div id="orgfdf8d08" class="figure">
|
|
<p><img src="figs/test_bench_measure_noise.png" alt="test_bench_measure_noise.png" />
|
|
</p>
|
|
<p><span class="figure-number">Figure 4: </span>Mounting Strut test bench as a clamping method to measure the encoder noise.</p>
|
|
</div>
|
|
</div>
|
|
</div>
|
|
|
|
<div id="outline-container-org68a3dfb" class="outline-2">
|
|
<h2 id="org68a3dfb"><span class="section-number-2">3</span> Measurement procedure</h2>
|
|
</div>
|
|
|
|
<div id="outline-container-orgf207a65" class="outline-2">
|
|
<h2 id="orgf207a65"><span class="section-number-2">4</span> Measurement Results</h2>
|
|