Compare commits

..

No commits in common. "9a06c0995ff1b41b43087952e8ba31dd50c86a22" and "15d8508bf0bd6a7af923fdb5b08d0a2f45e1ea70" have entirely different histories.

14 changed files with 97 additions and 1601 deletions

Binary file not shown.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 20 KiB

Binary file not shown.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 20 KiB

Binary file not shown.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 80 KiB

After

Width:  |  Height:  |  Size: 87 KiB

File diff suppressed because it is too large Load Diff

Binary file not shown.

Before

Width:  |  Height:  |  Size: 86 KiB

Binary file not shown.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 57 KiB

Binary file not shown.

View File

@ -3,7 +3,7 @@
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en" xml:lang="en">
<head>
<!-- 2021-02-11 jeu. 15:21 -->
<!-- 2021-02-10 mer. 15:14 -->
<meta http-equiv="Content-Type" content="text/html;charset=utf-8" />
<title>Encoder Renishaw Vionic - Test Bench</title>
<meta name="generator" content="Org mode" />
@ -39,21 +39,22 @@
<h2>Table of Contents</h2>
<div id="text-table-of-contents">
<ul>
<li><a href="#orgacaf822">1. Expected Performances</a></li>
<li><a href="#orgd1b48b9">2. Encoder Model</a></li>
<li><a href="#org9947f0d">3. Noise Measurement</a>
<li><a href="#orgee60877">1. Expected Performances</a></li>
<li><a href="#org78808d1">2. Encoder Model</a></li>
<li><a href="#org07e5c0c">3. Noise Measurement</a>
<ul>
<li><a href="#org7dd6ce0">3.1. Test Bench</a></li>
<li><a href="#orgd61ad80">3.2. Thermal drifts</a></li>
<li><a href="#org8f23c76">3.3. Time Domain signals</a></li>
<li><a href="#orgbd6cefe">3.4. Noise Spectral Density</a></li>
<li><a href="#orgc14197f">3.5. Noise Model</a></li>
<li><a href="#org1171cfb">3.1. Test Bench</a></li>
<li><a href="#org2d3c7ed">3.2. Thermal drifts</a></li>
<li><a href="#org12c8422">3.3. Time Domain signals</a></li>
<li><a href="#orgcfb7422">3.4. Noise Spectral Density</a></li>
<li><a href="#orgf450d0e">3.5. Noise Model</a></li>
<li><a href="#org5d6e2aa">3.6. Validity of the noise model</a></li>
</ul>
</li>
<li><a href="#orgbc58807">4. Linearity Measurement</a>
<li><a href="#orgbcdb22e">4. Linearity Measurement</a>
<ul>
<li><a href="#org38d4317">4.1. Test Bench</a></li>
<li><a href="#org9a6927b">4.2. Results</a></li>
<li><a href="#org0508ec2">4.1. Test Bench</a></li>
<li><a href="#org4e41106">4.2. Results</a></li>
</ul>
</li>
</ul>
@ -63,7 +64,7 @@
<p>This report is also available as a <a href="./test-bench-vionic.pdf">pdf</a>.</p>
<hr>
<div class="note" id="org34d0504">
<div class="note" id="orgf0dfbf1">
<p>
You can find below the documentation of:
</p>
@ -88,25 +89,25 @@ In particular, we would like to measure:
This document is structured as follow:
</p>
<ul class="org-ul">
<li>Section <a href="#orgafe2cb7">1</a>: the expected performance of the Vionic encoder system are described</li>
<li>Section <a href="#org1d1f36e">2</a>: a simple model of the encoder is developed</li>
<li>Section <a href="#orgf70a154">3</a>: the noise of the encoder is measured and a model of the noise is identified</li>
<li>Section <a href="#org3767bd5">4</a>: the linearity of the sensor is estimated</li>
<li>Section <a href="#org5825e63">1</a>: the expected performance of the Vionic encoder system are described</li>
<li>Section <a href="#org886dc10">2</a>: a simple model of the encoder is developed</li>
<li>Section <a href="#orgce8febf">3</a>: the noise of the encoder is measured and a model of the noise is identified</li>
<li>Section <a href="#org0a6ada3">4</a>: the linearity of the sensor is estimated</li>
</ul>
<div id="outline-container-orgacaf822" class="outline-2">
<h2 id="orgacaf822"><span class="section-number-2">1</span> Expected Performances</h2>
<div id="outline-container-orgee60877" class="outline-2">
<h2 id="orgee60877"><span class="section-number-2">1</span> Expected Performances</h2>
<div class="outline-text-2" id="text-1">
<p>
<a id="orgafe2cb7"></a>
<a id="org5825e63"></a>
</p>
<p>
The Vionic encoder is shown in Figure <a href="#org300cb52">1</a>.
The Vionic encoder is shown in Figure <a href="#org8649a60">1</a>.
</p>
<div id="org300cb52" class="figure">
<div id="org8649a60" class="figure">
<p><img src="figs/encoder_vionic.png" alt="encoder_vionic.png" />
</p>
<p><span class="figure-number">Figure 1: </span>Picture of the Vionic Encoder</p>
@ -134,21 +135,21 @@ Interpolation is within the readhead, with fine resolution versions being furthe
</blockquote>
<p>
The expected interpolation errors (non-linearity) is shown in Figure <a href="#org74b94f4">2</a>.
The expected interpolation errors (non-linearity) is shown in Figure <a href="#org35c5a3c">2</a>.
</p>
<div id="org74b94f4" class="figure">
<div id="org35c5a3c" class="figure">
<p><img src="./figs/vionic_expected_noise.png" alt="vionic_expected_noise.png" />
</p>
<p><span class="figure-number">Figure 2: </span>Expected interpolation errors for the Vionic Encoder</p>
</div>
<p>
The characteristics as advertise in the manual as well as our specifications are shown in Table <a href="#org12ad600">1</a>.
The characteristics as advertise in the manual as well as our specifications are shown in Table <a href="#org025a9b8">1</a>.
</p>
<table id="org12ad600" border="2" cellspacing="0" cellpadding="6" rules="groups" frame="hsides">
<table id="org025a9b8" border="2" cellspacing="0" cellpadding="6" rules="groups" frame="hsides">
<caption class="t-above"><span class="table-number">Table 1:</span> Characteristics of the Vionic compared with the specifications</caption>
<colgroup>
@ -168,7 +169,7 @@ The characteristics as advertise in the manual as well as our specifications are
<tbody>
<tr>
<td class="org-left">Time Delay</td>
<td class="org-center">&lt; 10 ns</td>
<td class="org-center">&#xa0;</td>
<td class="org-center">&lt; 0.5 ms</td>
</tr>
@ -200,11 +201,11 @@ The characteristics as advertise in the manual as well as our specifications are
</div>
</div>
<div id="outline-container-orgd1b48b9" class="outline-2">
<h2 id="orgd1b48b9"><span class="section-number-2">2</span> Encoder Model</h2>
<div id="outline-container-org78808d1" class="outline-2">
<h2 id="org78808d1"><span class="section-number-2">2</span> Encoder Model</h2>
<div class="outline-text-2" id="text-2">
<p>
<a id="org1d1f36e"></a>
<a id="org886dc10"></a>
</p>
<p>
@ -217,53 +218,38 @@ It is also characterized by its measurement noise \(n\) that can be described by
</p>
<p>
The model of the encoder is shown in Figure <a href="#orge3dfe4a">3</a>.
The model of the encoder is shown in Figure <a href="#orgd01aa78">3</a>.
</p>
<div id="orge3dfe4a" class="figure">
<div id="orgd01aa78" class="figure">
<p><img src="figs/encoder-model-schematic.png" alt="encoder-model-schematic.png" />
</p>
<p><span class="figure-number">Figure 3: </span>Model of the Encoder</p>
</div>
<p>
We can also use a transfer function \(G_n(s)\) to shape a noise \(\tilde{n}\) with unity ASD as shown in Figure <a href="#org74b94f4">2</a>.
We can also use a transfer function \(G_n(s)\) to shape a noise \(\tilde{n}\) with unity ASD as shown in Figure <a href="#org35c5a3c">2</a>.
</p>
<div id="orgb259ef8" class="figure">
<div id="org0de813a" class="figure">
<p><img src="figs/encoder-model-schematic-with-asd.png" alt="encoder-model-schematic-with-asd.png" />
</p>
</div>
</div>
</div>
<div id="outline-container-org9947f0d" class="outline-2">
<h2 id="org9947f0d"><span class="section-number-2">3</span> Noise Measurement</h2>
<div id="outline-container-org07e5c0c" class="outline-2">
<h2 id="org07e5c0c"><span class="section-number-2">3</span> Noise Measurement</h2>
<div class="outline-text-2" id="text-3">
<p>
<a id="orgf70a154"></a>
<a id="orgce8febf"></a>
</p>
<p>
This part is structured as follow:
</p>
<ul class="org-ul">
<li>Section <a href="#org1bbddb3">3.1</a>: the measurement bench is described</li>
<li>Section <a href="#orge37ddeb">3.2</a>: long measurement is performed to estimate the low frequency drifts in the measurement</li>
<li>Section <a href="#orgbe1c0e1">3.3</a>: high frequency measurements are performed to estimate the high frequency noise</li>
<li>Section <a href="#orgfafa9fd">3.4</a>: the Spectral density of the measurement noise is estimated</li>
<li>Section <a href="#org2284feb">3.5</a>: finally, the measured noise is modeled</li>
</ul>
</div>
<div id="outline-container-org7dd6ce0" class="outline-3">
<h3 id="org7dd6ce0"><span class="section-number-3">3.1</span> Test Bench</h3>
<div id="outline-container-org1171cfb" class="outline-3">
<h3 id="org1171cfb"><span class="section-number-3">3.1</span> Test Bench</h3>
<div class="outline-text-3" id="text-3-1">
<p>
<a id="org1bbddb3"></a>
</p>
<p>
To measure the noise \(n\) of the encoder, one can rigidly fix the head and the ruler together such that no motion should be measured.
Then, the measured signal \(y_m\) corresponds to the noise \(n\).
@ -271,138 +257,62 @@ Then, the measured signal \(y_m\) corresponds to the noise \(n\).
</div>
</div>
<div id="outline-container-orgd61ad80" class="outline-3">
<h3 id="orgd61ad80"><span class="section-number-3">3.2</span> Thermal drifts</h3>
<div id="outline-container-org2d3c7ed" class="outline-3">
<h3 id="org2d3c7ed"><span class="section-number-3">3.2</span> Thermal drifts</h3>
<div class="outline-text-3" id="text-3-2">
<p>
<a id="orge37ddeb"></a>
Measured displacement were recording during approximately 40 hours with a sample frequency of 100Hz.
A first order low pass filter with a corner frequency of 1Hz
</p>
<div class="org-src-container">
<pre class="src src-matlab">enc_l = load(<span class="org-string">'mat/noise_meas_40h_100Hz_1.mat'</span>, <span class="org-string">'t'</span>, <span class="org-string">'x'</span>);
</pre>
</div>
<p>
The measured time domain data are shown in Figure <a href="#org55bfe2a">5</a>.
</p>
<div id="org55bfe2a" class="figure">
<p><img src="figs/vionic_drifts_time.png" alt="vionic_drifts_time.png" />
</p>
<p><span class="figure-number">Figure 5: </span>Measured thermal drifts</p>
</div>
<p>
The measured data seems to experience a constant drift after approximately 20 hour.
Let&rsquo;s estimate this drift.
</p>
<pre class="example">
The mean drift is approximately 60.9 [nm/hour] or 1.0 [nm/min]
</pre>
<p>
Comparison between the data and the linear fit is shown in Figure <a href="#org1085735">6</a>.
</p>
<div id="org1085735" class="figure">
<p><img src="figs/vionic_drifts_linear_fit.png" alt="vionic_drifts_linear_fit.png" />
</p>
<p><span class="figure-number">Figure 6: </span>Measured drift and linear fit</p>
</div>
<p>
Let&rsquo;s now estimate the Power Spectral Density of the measured displacement.
The obtained low frequency ASD is shown in Figure <a href="#orgf2675d7">7</a>.
</p>
<div id="orgf2675d7" class="figure">
<p><img src="figs/vionic_noise_asd_low_freq.png" alt="vionic_noise_asd_low_freq.png" />
</p>
<p><span class="figure-number">Figure 7: </span>Amplitude Spectral density of the measured displacement</p>
</div>
<ul class="org-ul">
<li class="off"><code>[&#xa0;]</code> picture of the setup</li>
<li class="off"><code>[&#xa0;]</code> long thermal drifts</li>
<li class="off"><code>[&#xa0;]</code> once stabilize, look at the noise</li>
<li class="off"><code>[&#xa0;]</code> compute low frequency ASD (may still be thermal drifts of the mechanics and not noise)</li>
</ul>
</div>
</div>
<div id="outline-container-org8f23c76" class="outline-3">
<h3 id="org8f23c76"><span class="section-number-3">3.3</span> Time Domain signals</h3>
<div id="outline-container-org12c8422" class="outline-3">
<h3 id="org12c8422"><span class="section-number-3">3.3</span> Time Domain signals</h3>
<div class="outline-text-3" id="text-3-3">
<p>
<a id="orgbe1c0e1"></a>
First we load the data.
The raw measured data as well as the low pass filtered data (using a first order low pass filter with a cut-off at 10Hz) are shown in Figure <a href="#org0525912">5</a>.
</p>
<p>
Then, and for all the 7 encoders, we record the measured motion during 100s with a sampling frequency of 20kHz.
</p>
<p>
The raw measured data as well as the low pass filtered data (using a first order low pass filter with a cut-off at 10Hz) are shown in Figure <a href="#orgbd876dc">8</a>.
</p>
<div id="orgbd876dc" class="figure">
<div id="org0525912" class="figure">
<p><img src="figs/vionic_noise_raw_lpf.png" alt="vionic_noise_raw_lpf.png" />
</p>
<p><span class="figure-number">Figure 8: </span>Time domain measurement (raw data and low pass filtered data with first order 10Hz LPF)</p>
<p><span class="figure-number">Figure 5: </span>Time domain measurement (raw data and low pass filtered data with first order 10Hz LPF)</p>
</div>
<p>
The time domain data for all the encoders are compared in Figure <a href="#org63a82cb">9</a>.
The time domain data for all the encoders are compared in Figure <a href="#org5c2c4fa">6</a>.
</p>
<p>
We can see some drifts that are in the order of few nm to 20nm per minute.
As shown in Section <a href="#orge37ddeb">3.2</a>, these drifts should diminish over time down to 1nm/min.
</p>
<div id="org63a82cb" class="figure">
<div id="org5c2c4fa" class="figure">
<p><img src="figs/vionic_noise_time.png" alt="vionic_noise_time.png" />
</p>
<p><span class="figure-number">Figure 9: </span>Comparison of the time domain measurement</p>
<p><span class="figure-number">Figure 6: </span>Comparison of the time domain measurement</p>
</div>
</div>
</div>
<div id="outline-container-orgbd6cefe" class="outline-3">
<h3 id="orgbd6cefe"><span class="section-number-3">3.4</span> Noise Spectral Density</h3>
<div id="outline-container-orgcfb7422" class="outline-3">
<h3 id="orgcfb7422"><span class="section-number-3">3.4</span> Noise Spectral Density</h3>
<div class="outline-text-3" id="text-3-4">
<p>
<a id="orgfafa9fd"></a>
The amplitude spectral density is computed and shown in Figure <a href="#orged52478">7</a>.
</p>
<p>
The amplitude spectral densities for all the encoder are computed and shown in Figure <a href="#org4b13cc6">10</a>.
</p>
<div id="org4b13cc6" class="figure">
<div id="orged52478" class="figure">
<p><img src="figs/vionic_noise_asd.png" alt="vionic_noise_asd.png" />
</p>
<p><span class="figure-number">Figure 10: </span>Amplitude Spectral Density of the measured signal</p>
</div>
<p>
We can combine these measurements with the low frequency noise computed in Section <a href="#orge37ddeb">3.2</a>.
The obtained ASD is shown in Figure <a href="#orgec960f3">11</a>.
</p>
<div id="orgec960f3" class="figure">
<p><img src="figs/vionic_noise_asd_combined.png" alt="vionic_noise_asd_combined.png" />
</p>
<p><span class="figure-number">Figure 11: </span>Combined low frequency and high frequency noise measurements</p>
<p><span class="figure-number">Figure 7: </span>Amplitude Spectral Density of the measured signal</p>
</div>
</div>
</div>
<div id="outline-container-orgc14197f" class="outline-3">
<h3 id="orgc14197f"><span class="section-number-3">3.5</span> Noise Model</h3>
<div id="outline-container-orgf450d0e" class="outline-3">
<h3 id="orgf450d0e"><span class="section-number-3">3.5</span> Noise Model</h3>
<div class="outline-text-3" id="text-3-5">
<p>
<a id="org2284feb"></a>
</p>
<p>
Let&rsquo;s create a transfer function that approximate the measured noise of the encoder.
</p>
@ -412,18 +322,23 @@ Let&rsquo;s create a transfer function that approximate the measured noise of th
</div>
<p>
The amplitude of the transfer function and the measured ASD are shown in Figure <a href="#org904aecb">12</a>.
The amplitude of the transfer function and the measured ASD are shown in Figure <a href="#orgd40fb21">8</a>.
</p>
<div id="org904aecb" class="figure">
<div id="orgd40fb21" class="figure">
<p><img src="figs/vionic_noise_asd_model.png" alt="vionic_noise_asd_model.png" />
</p>
<p><span class="figure-number">Figure 12: </span>Measured ASD of the noise and modeled one</p>
<p><span class="figure-number">Figure 8: </span>Measured ASD of the noise and modeled one</p>
</div>
</div>
</div>
<div id="outline-container-org5d6e2aa" class="outline-3">
<h3 id="org5d6e2aa"><span class="section-number-3">3.6</span> Validity of the noise model</h3>
<div class="outline-text-3" id="text-3-6">
<p>
The cumulative amplitude spectrum is now computed and shown in Figure <a href="#orgff7d2cd">13</a>.
The cumulative amplitude spectrum is now computed and shown in Figure <a href="#orgf87a6b7">9</a>.
</p>
<p>
@ -431,24 +346,24 @@ We can see that the Root Mean Square value of the measurement noise is \(\approx
</p>
<div id="orgff7d2cd" class="figure">
<div id="orgf87a6b7" class="figure">
<p><img src="figs/vionic_noise_cas_model.png" alt="vionic_noise_cas_model.png" />
</p>
<p><span class="figure-number">Figure 13: </span>Meassured CAS of the noise and modeled one</p>
<p><span class="figure-number">Figure 9: </span>Meassured CAS of the noise and modeled one</p>
</div>
</div>
</div>
</div>
<div id="outline-container-orgbc58807" class="outline-2">
<h2 id="orgbc58807"><span class="section-number-2">4</span> Linearity Measurement</h2>
<div id="outline-container-orgbcdb22e" class="outline-2">
<h2 id="orgbcdb22e"><span class="section-number-2">4</span> Linearity Measurement</h2>
<div class="outline-text-2" id="text-4">
<p>
<a id="org3767bd5"></a>
<a id="org0a6ada3"></a>
</p>
</div>
<div id="outline-container-org38d4317" class="outline-3">
<h3 id="org38d4317"><span class="section-number-3">4.1</span> Test Bench</h3>
<div id="outline-container-org0508ec2" class="outline-3">
<h3 id="org0508ec2"><span class="section-number-3">4.1</span> Test Bench</h3>
<div class="outline-text-3" id="text-4-1">
<p>
In order to measure the linearity, we have to compare the measured displacement with a reference sensor with a known linearity.
@ -457,7 +372,7 @@ An actuator should also be there so impose a displacement.
</p>
<p>
One idea is to use the test-bench shown in Figure <a href="#org5a7f983">14</a>.
One idea is to use the test-bench shown in Figure <a href="#orge0a809b">10</a>.
</p>
<p>
@ -470,22 +385,22 @@ As the interferometer has a very large bandwidth, we should be able to estimate
</p>
<div id="org5a7f983" class="figure">
<div id="orge0a809b" class="figure">
<p><img src="figs/test_bench_encoder_calibration.png" alt="test_bench_encoder_calibration.png" />
</p>
<p><span class="figure-number">Figure 14: </span>Schematic of the test bench</p>
<p><span class="figure-number">Figure 10: </span>Schematic of the test bench</p>
</div>
</div>
</div>
<div id="outline-container-org9a6927b" class="outline-3">
<h3 id="org9a6927b"><span class="section-number-3">4.2</span> Results</h3>
<div id="outline-container-org4e41106" class="outline-3">
<h3 id="org4e41106"><span class="section-number-3">4.2</span> Results</h3>
</div>
</div>
</div>
<div id="postamble" class="status">
<p class="author">Author: Dehaeze Thomas</p>
<p class="date">Created: 2021-02-11 jeu. 15:21</p>
<p class="date">Created: 2021-02-10 mer. 15:14</p>
</div>
</body>
</html>

View File

@ -105,7 +105,7 @@ The characteristics as advertise in the manual as well as our specifications are
| <l> | <c> | <c> |
| *Characteristics* | *Manual* | *Specification* |
|-------------------+--------------+-----------------|
| Time Delay | < 10 ns | < 0.5 ms |
| Time Delay | | < 0.5 ms |
| Bandwidth | > 500 kHz | > 5 kHz |
| Noise | < 1.6 nm rms | < 50 nm rms |
| Linearity | < +/- 15 nm | |
@ -169,18 +169,7 @@ We can also use a transfer function $G_n(s)$ to shape a noise $\tilde{n}$ with u
* Noise Measurement
<<sec:noise_measurement>>
** Introduction :ignore:
This part is structured as follow:
- Section [[sec:noise_bench]]: the measurement bench is described
- Section [[sec:thermal_drifts]]: long measurement is performed to estimate the low frequency drifts in the measurement
- Section [[sec:vionic_noise_time]]: high frequency measurements are performed to estimate the high frequency noise
- Section [[sec:noise_asd]]: the Spectral density of the measurement noise is estimated
- Section [[sec:vionic_noise_model]]: finally, the measured noise is modeled
** Test Bench
<<sec:noise_bench>>
To measure the noise $n$ of the encoder, one can rigidly fix the head and the ruler together such that no motion should be measured.
Then, the measured signal $y_m$ corresponds to the noise $n$.
@ -203,119 +192,14 @@ addpath('./matlab/');
addpath('./mat/');
#+end_src
** Thermal drifts
<<sec:thermal_drifts>>
Measured displacement were recording during approximately 40 hours with a sample frequency of 100Hz.
A first order low pass filter with a corner frequency of 1Hz
#+begin_src matlab
enc_l = load('mat/noise_meas_40h_100Hz_1.mat', 't', 'x');
#+end_src
The measured time domain data are shown in Figure [[fig:vionic_drifts_time]].
#+begin_src matlab :exports none
enc_l.x = enc_l.x(enc_l.t > 5); % Remove first 5 seconds
enc_l.t = enc_l.t(enc_l.t > 5); % Remove first 5 seconds
enc_l.t = enc_l.t - enc_l.t(1); % Start at 0
enc_l.x = enc_l.x - mean(enc_l.x(enc_l.t < 1)); % Start at zero displacement
#+end_src
#+begin_src matlab :exports none
figure;
hold on;
plot(enc_l.t/3600, 1e9*enc_l.x, '-');
hold off;
xlabel('Time [h]');
ylabel('Displacement [nm]');
xlim([0, 40]);
#+end_src
#+begin_src matlab :tangle no :exports results :results file replace
exportFig('figs/vionic_drifts_time.pdf', 'width', 'wide', 'height', 'normal');
#+end_src
#+name: fig:vionic_drifts_time
#+caption: Measured thermal drifts
#+RESULTS:
[[file:figs/vionic_drifts_time.png]]
The measured data seems to experience a constant drift after approximately 20 hour.
Let's estimate this drift.
#+begin_src matlab :exports none
t0 = 20*3600; % Start time [s]
x_stab = enc_l.x(enc_l.t > t0);
x_stab = x_stab - x_stab(1);
t_stab = enc_l.t(enc_l.t > t0);
t_stab = t_stab - t_stab(1);
#+end_src
#+begin_src matlab :results value replace :exports results
sprintf('The mean drift is approximately %.1f [nm/hour] or %.1f [nm/min]', 3600*1e9*(t_stab\x_stab), 60*1e9*(t_stab\x_stab))
#+end_src
#+RESULTS:
: The mean drift is approximately 60.9 [nm/hour] or 1.0 [nm/min]
Comparison between the data and the linear fit is shown in Figure [[fig:vionic_drifts_linear_fit]].
#+begin_src matlab :exports none
figure;
hold on;
plot(t_stab/3600, 1e9*x_stab, '-');
plot(t_stab/3600, 1e9*t_stab*(t_stab\x_stab), 'k--');
hold off;
xlabel('Time [h]');
ylabel('Displacement [nm]');
xlim([0, 20]);
#+end_src
#+begin_src matlab :tangle no :exports results :results file replace
exportFig('figs/vionic_drifts_linear_fit.pdf', 'width', 'wide', 'height', 'normal');
#+end_src
#+name: fig:vionic_drifts_linear_fit
#+caption: Measured drift and linear fit
#+RESULTS:
[[file:figs/vionic_drifts_linear_fit.png]]
Let's now estimate the Power Spectral Density of the measured displacement.
The obtained low frequency ASD is shown in Figure [[fig:vionic_noise_asd_low_freq]].
#+begin_src matlab :exports none
% Compute sampling Frequency
Ts = (enc_l.t(end) - enc_l.t(1))/(length(enc_l.t)-1);
Fs = 1/Ts;
% Hannning Windows
win = hanning(ceil(60*10/Ts));
[pxx_l, f_l] = pwelch(x_stab, win, [], [], Fs);
#+end_src
#+begin_src matlab :exports none
figure;
hold on;
plot(f_l, sqrt(pxx_l))
set(gca, 'XScale', 'log'); set(gca, 'YScale', 'log');
xlabel('Frequency [Hz]'); ylabel('ASD [$m/\sqrt{Hz}$]');
xlim([1e-2, 1e0]);
ylim([1e-11, 1e-8]);
#+end_src
#+begin_src matlab :tangle no :exports results :results file replace
exportFig('figs/vionic_noise_asd_low_freq.pdf', 'width', 'side', 'height', 'normal');
#+end_src
#+name: fig:vionic_noise_asd_low_freq
#+caption: Amplitude Spectral density of the measured displacement
#+RESULTS:
[[file:figs/vionic_noise_asd_low_freq.png]]
** TODO Thermal drifts
- [ ] picture of the setup
- [ ] long thermal drifts
- [ ] once stabilize, look at the noise
- [ ] compute low frequency ASD (may still be thermal drifts of the mechanics and not noise)
** Time Domain signals
<<sec:vionic_noise_time>>
Then, and for all the 7 encoders, we record the measured motion during 100s with a sampling frequency of 20kHz.
First we load the data.
#+begin_src matlab :exports none
%% Load all the measurements
enc = {};
@ -353,9 +237,6 @@ exportFig('figs/vionic_noise_raw_lpf.pdf', 'width', 'wide', 'height', 'normal');
[[file:figs/vionic_noise_raw_lpf.png]]
The time domain data for all the encoders are compared in Figure [[fig:vionic_noise_time]].
We can see some drifts that are in the order of few nm to 20nm per minute.
As shown in Section [[sec:thermal_drifts]], these drifts should diminish over time down to 1nm/min.
#+begin_src matlab :exports none
figure;
hold on;
@ -379,9 +260,7 @@ exportFig('figs/vionic_noise_time.pdf', 'width', 'wide', 'height', 'normal');
[[file:figs/vionic_noise_time.png]]
** Noise Spectral Density
<<sec:noise_asd>>
The amplitude spectral densities for all the encoder are computed and shown in Figure [[fig:vionic_noise_asd]].
The amplitude spectral density is computed and shown in Figure [[fig:vionic_noise_asd]].
#+begin_src matlab :exports none
% Compute sampling Frequency
Ts = (enc{1}.t(end) - enc{1}.t(1))/(length(enc{1}.t)-1);
@ -409,7 +288,7 @@ end
set(gca, 'XScale', 'log'); set(gca, 'YScale', 'log');
xlabel('Frequency [Hz]'); ylabel('ASD [$m/\sqrt{Hz}$]');
xlim([10, Fs/2]);
ylim([1e-11, 1e-9]);
ylim([1e-11, 1e-10]);
legend('location', 'northeast');
#+end_src
@ -422,32 +301,7 @@ exportFig('figs/vionic_noise_asd.pdf', 'width', 'wide', 'height', 'normal');
#+RESULTS:
[[file:figs/vionic_noise_asd.png]]
We can combine these measurements with the low frequency noise computed in Section [[sec:thermal_drifts]].
The obtained ASD is shown in Figure [[fig:vionic_noise_asd_combined]].
#+begin_src matlab :exports none
[pxx_h, f_h] = pwelch(enc{2}.x, hanning(ceil(10/Ts)), [], [], Fs);
figure;
hold on;
plot(f_h(f_h>0.6), sqrt(pxx_h(f_h>0.6)), 'k-');
plot(f_l(f_l<1), sqrt(pxx_l(f_l<1)), 'k-')
set(gca, 'XScale', 'log'); set(gca, 'YScale', 'log');
xlabel('Frequency [Hz]'); ylabel('ASD [$m/\sqrt{Hz}$]');
xlim([1e-2, Fs/2]);
ylim([1e-12, 1e-8]);
#+end_src
#+begin_src matlab :tangle no :exports results :results file replace
exportFig('figs/vionic_noise_asd_combined.pdf', 'width', 'wide', 'height', 'normal');
#+end_src
#+name: fig:vionic_noise_asd_combined
#+caption: Combined low frequency and high frequency noise measurements
#+RESULTS:
[[file:figs/vionic_noise_asd_combined.png]]
** Noise Model
<<sec:vionic_noise_model>>
Let's create a transfer function that approximate the measured noise of the encoder.
#+begin_src matlab
@ -459,7 +313,7 @@ The amplitude of the transfer function and the measured ASD are shown in Figure
#+begin_src matlab :exports none
figure;
hold on;
plot(f, sqrt(enc{1}.pxx), 'color', [0, 0, 0, 0.5], 'DisplayName', '$\Gamma_n(\omega)$');
plot(f, sqrt(p1), 'color', [0, 0, 0, 0.5], 'DisplayName', '$\Gamma_n(\omega)$');
for i=2:7
plot(f, sqrt(enc{i}.pxx), 'color', [0, 0, 0, 0.5], ...
'HandleVisibility', 'off');
@ -482,6 +336,7 @@ exportFig('figs/vionic_noise_asd_model.pdf', 'width', 'wide', 'height', 'normal'
#+RESULTS:
[[file:figs/vionic_noise_asd_model.png]]
** Validity of the noise model
The cumulative amplitude spectrum is now computed and shown in Figure [[fig:vionic_noise_cas_model]].
We can see that the Root Mean Square value of the measurement noise is $\approx 1.6 \, nm$ as advertise in the datasheet.