** Conclusion
|
** Conclusion
|
||||||
|
|
||||||
|
When two flexible joints are fixed at each ends of the APA, the APA is mostly in a free/free condition in terms of bending/torsion (the bending/torsional stiffness of the joints being very small).
|
||||||
|
|
||||||
|
In the current tests, the APA are in a fixed/free condition.
|
||||||
|
Therefore, it is quite obvious that we measured higher resonance frequencies than what is foreseen for the struts.
|
||||||
|
It is however quite interesting that there is a factor $\approx \sqrt{2}$ between the two (increased of the stiffness by a factor 2?).
|
||||||
|
|
||||||
#+name: tab:apa300ml_measured_modes_freq
|
#+name: tab:apa300ml_measured_modes_freq
|
||||||
#+caption: Measured frequency of the modes
|
#+caption: Measured frequency of the modes
|
||||||
#+attr_latex: :environment tabularx :width 0.3\linewidth :align lX
|
#+attr_latex: :environment tabularx :width \linewidth :align lX
|
||||||
#+attr_latex: :center t :booktabs t :float t
|
#+attr_latex: :center t :booktabs t :float t
|
||||||
| Mode | Measured Frequency |
|
| Mode | Strut Mode | Measured Frequency |
|
||||||
|-----------+--------------------|
|
|-----------+------------+--------------------|
|
||||||
| X-Bending | 280Hz |
|
| X-Bending | 189Hz | 280Hz |
|
||||||
| Y-Bending | 410Hz |
|
| Y-Bending | 285Hz | 410Hz |
|
||||||
| Z-Torsion | ? |
|
| Z-Torsion | 400Hz | ? |
|
||||||
|
|
||||||