nass-micro-station-measurem.../disturbance-ty-sr/index.org

49 lines
1.6 KiB
Org Mode
Raw Normal View History

#+TITLE:Measurements
:DRAWER:
#+STARTUP: overview
#+LANGUAGE: en
#+EMAIL: dehaeze.thomas@gmail.com
#+AUTHOR: Dehaeze Thomas
#+HTML_LINK_HOME: ../index.html
#+HTML_LINK_UP: ../index.html
#+HTML_HEAD: <link rel="stylesheet" type="text/css" href="../css/htmlize.css"/>
#+HTML_HEAD: <link rel="stylesheet" type="text/css" href="../css/readtheorg.css"/>
#+HTML_HEAD: <link rel="stylesheet" type="text/css" href="../css/zenburn.css"/>
#+HTML_HEAD: <script type="text/javascript" src="../js/jquery.min.js"></script>
#+HTML_HEAD: <script type="text/javascript" src="../js/bootstrap.min.js"></script>
#+HTML_HEAD: <script type="text/javascript" src="../js/jquery.stickytableheaders.min.js"></script>
#+HTML_HEAD: <script type="text/javascript" src="../js/readtheorg.js"></script>
#+HTML_MATHJAX: align: center tagside: right font: TeX
#+PROPERTY: header-args:matlab :session *MATLAB*
#+PROPERTY: header-args:matlab+ :comments org
#+PROPERTY: header-args:matlab+ :results none
#+PROPERTY: header-args:matlab+ :exports both
#+PROPERTY: header-args:matlab+ :eval no-export
#+PROPERTY: header-args:matlab+ :output-dir figs
#+PROPERTY: header-args:shell :eval no-export
:END:
* Measurement description
All the stages are OFF except Ty and Slip-Ring.
Each of the signal is amplified by voltage amplifier:
- 40db!!!
- AC
- 1kHz
col1: marble
col2: sample
Rotating the slip-ring at 60rpm and scans with the Ty at 1Hz.
Everything on the Z direction
- meas 50: Slip-Ring at 1Hz, Ty OFF
- meas 51: Slip-Ring at 1Hz, Ty ON (The current and cnt error of Ty is also registered)
- meas 52: Slip-Ring at 1Hz, Ty 1Hz 600000cnt