Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
f684da767e | ||
|
|
aedf928fd0 | ||
|
|
785feb7f26 | ||
|
|
7d39832b2a | ||
|
|
148338e9c2 | ||
|
|
9bbd8cd325 | ||
|
|
a0cd55427a | ||
|
|
41fc48b8c0 | ||
|
|
adec6e712f | ||
|
|
2490e8bbb1 | ||
|
|
0699938cd5 | ||
|
|
0097be4114 | ||
|
|
ac11e1e4a4 | ||
|
|
432702d1a4 | ||
|
|
665774dd08 | ||
|
|
9c3bf36f36 | ||
|
|
eaa0af474b | ||
|
|
23fc8a95cc | ||
|
|
f12fec1e16 | ||
|
|
4ce1feb36e |
No files matched your search
@@ -57,5 +57,7 @@
|
||||
}
|
||||
}
|
||||
|
||||
.list-zettels .subcategory { list-style: none; margin-top: .8em; }
|
||||
.list-zettels .list-subtitle { font-weight: bold; }
|
||||
|
||||
.site-navbar .menu-item-link.active { color: #c05b4d; font-weight: bold; }
|
||||
.header .site-navbar { float: none; text-align: center; }
|
||||
.header .site-navbar .menu { padding-right: 0; }
|
||||
@@ -28,9 +28,13 @@
|
||||
color: #8a8a8a;
|
||||
}
|
||||
|
||||
.pub-title,
|
||||
a.pub-title {
|
||||
/* Title in the default text color, and in the link color when it links to a page */
|
||||
.pub-title {
|
||||
font-weight: 600;
|
||||
color: inherit;
|
||||
}
|
||||
|
||||
a.pub-title {
|
||||
color: hsl(232, 61%, 64%);
|
||||
}
|
||||
|
||||
@@ -59,6 +63,11 @@ a.pub-title:hover {
|
||||
|
||||
.pub-links a {
|
||||
white-space: nowrap;
|
||||
color: #c05b4d;
|
||||
}
|
||||
|
||||
.pub-links a:hover {
|
||||
border-bottom: 1px solid #c05b4d;
|
||||
}
|
||||
|
||||
@media (max-width: 600px) {
|
||||
@@ -66,3 +75,7 @@ a.pub-title:hover {
|
||||
min-width: 2.4em;
|
||||
}
|
||||
}
|
||||
|
||||
.pub-sep {
|
||||
color: #8a8a8a;
|
||||
}
|
||||
@@ -1,7 +1,7 @@
|
||||
baseURL = "/"
|
||||
locale = "en"
|
||||
defaultContentLanguage = "en"
|
||||
title = "My digital brain"
|
||||
title = "Thomas Dehaeze"
|
||||
preserveTaxonomyNames = true
|
||||
enableRobotsTXT = true
|
||||
enableEmoji = true
|
||||
@@ -26,11 +26,11 @@ changefreq = "weekly"
|
||||
priority = 0.5
|
||||
filename = "sitemap.xml"
|
||||
|
||||
# [[menu.main]]
|
||||
# name = "Home"
|
||||
# weight = 10
|
||||
# identifier = "home"
|
||||
# url = "/"
|
||||
[[menu.main]]
|
||||
name = "Home"
|
||||
weight = 10
|
||||
identifier = "home"
|
||||
url = "/"
|
||||
|
||||
[[menu.main]]
|
||||
name = "Publications"
|
||||
@@ -39,16 +39,16 @@ identifier = "research"
|
||||
url = "/research/"
|
||||
|
||||
[[menu.main]]
|
||||
name = "Zettels"
|
||||
weight = 30
|
||||
identifier = "zettels"
|
||||
url = "/zettels/"
|
||||
name = "Projects"
|
||||
weight = 25
|
||||
identifier = "projects"
|
||||
url = "/projects/"
|
||||
|
||||
[[menu.main]]
|
||||
name = "Bibliography"
|
||||
weight = 50
|
||||
identifier = "bibliography"
|
||||
url = "/bibliography/"
|
||||
name = "Notes"
|
||||
weight = 30
|
||||
identifier = "notes"
|
||||
url = "/notes/"
|
||||
|
||||
[[menu.main]]
|
||||
name = "Search"
|
||||
@@ -56,6 +56,9 @@ weight = 70
|
||||
identifier = "search"
|
||||
url = "/search/"
|
||||
|
||||
[permalinks]
|
||||
zettels = "/notes/:slug/"
|
||||
|
||||
[outputs]
|
||||
home = ["HTML", "RSS", "JSON"]
|
||||
|
||||
@@ -66,9 +69,8 @@ debug = false
|
||||
since = "2020"
|
||||
gitRepo = ""
|
||||
|
||||
logoTitle = "Digital Brain"
|
||||
keywords = ["org-roam","research"]
|
||||
description = "My personnal digital brain"
|
||||
keywords = ["mechatronics","research"]
|
||||
description = "My personnal website about mechatronics"
|
||||
|
||||
archivePaginate = 5
|
||||
|
||||
|
||||
@@ -0,0 +1,12 @@
|
||||
+++
|
||||
title = "Thomas Dehaeze"
|
||||
draft = false
|
||||
+++
|
||||
|
||||
I am a control and mechatronics researcher at the [European Synchrotron (ESRF)](https://www.esrf.fr) in Grenoble.
|
||||
I recently completed a PhD at the [Precision Mechatronics Laboratory](https://www.pml.uliege.be/) (University of Liège) on nano active stabilization of samples for tomography experiments.
|
||||
|
||||
My current work is on the mechatronic design of nano-positioning systems for synchrotron beamlines.
|
||||
This spans the whole chain, from dynamical modelling, to control (active damping, sensor fusion, real-time implementation), and online metrology.
|
||||
|
||||
You can reach me at [thomas@tdehaeze.xyz](mailto:thomas@tdehaeze.xyz).
|
||||
@@ -31,7 +31,7 @@ Year
|
||||
- \\(T\_{wx}(s)\\) is called the **transmissibility** of the isolator. It characterize the way seismic vibrations \\(w\\) are transmitted to the equipment.
|
||||
- \\(T\_{Fx}(s)\\) is called the **compliance**. It characterize the capacity of disturbing forces \\(F\\) to create motion \\(x\\) of the equipment.
|
||||
|
||||
In order to minimize the vibrations of a sensitive equipment, a general objective to design a good isolator is to minimize both \\(\abs{T\_{wx}}\\) and \\(\abs{T\_{Fx}}\\) in the frequency range of interest.
|
||||
In order to minimize the vibrations of a sensitive equipment, a general objective to design a good isolator is to minimize both \\(|T\_{wx}|\\) and \\(|T\_{Fx}|\\) in the frequency range of interest.
|
||||
|
||||
To decrease the amplitude of the overshoot at the resonance frequency, **damping** can be increased.
|
||||
The price to pay is degradation of the isolation at high frequency (the roll off becomes \\(-1\\) instead of \\(-2\\)).
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Exploring the pareto fronts of actuation technologies for high performance mechatronic systems"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = true
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Fly-scan-oriented motion analyses and upgraded beamline integration architecture for the high-dynamic double-crystal monochromator at sirius/lnls"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = true
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Exploiting additional actuators and sensors for nano-positioning robust motion control"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
draft = true
|
||||
+++
|
||||
|
||||
Tags
|
||||
|
||||
@@ -1,26 +0,0 @@
|
||||
+++
|
||||
title = "Simultaneous vibration isolation and pointing control of flexure jointed hexapods"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
: [Stewart Platforms]({{< relref "stewart_platforms.md" >}}), [Vibration Isolation]({{< relref "vibration_isolation.md" >}})
|
||||
|
||||
Reference
|
||||
: (<a href="#citeproc_bib_item_1">Li, Hamann, and McInroy 2001</a>)
|
||||
|
||||
Author(s)
|
||||
: Li, X., Hamann, J. C., & McInroy, J. E.
|
||||
|
||||
Year
|
||||
: 2001
|
||||
|
||||
- if the hexapod is designed such that the payload mass/inertia matrix (\\(M\_x\\)) and \\(J^T J\\) are diagonal, the dynamics from \\(u\\) to \\(y\\) are decoupled.
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
<style>.csl-entry{text-indent: -1.5em; margin-left: 1.5em;}</style><div class="csl-bib-body">
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_1"></a>Li, Xiaochun, Jerry C. Hamann, and John E. McInroy. 2001. “Simultaneous Vibration Isolation and Pointing Control of Flexure Jointed Hexapods.” In <i>Smart Structures and Materials 2001: Smart Structures and Integrated Systems</i>. doi:<a href="https://doi.org/10.1117/12.436521">10.1117/12.436521</a>.</div>
|
||||
</div>
|
||||
@@ -115,7 +115,7 @@ where:
|
||||
- \\(\mathcal{F}\_e\\) represents a vector of exogenous generalized forces applied at the center of mass
|
||||
- \\(g\\) is the gravity vector
|
||||
|
||||
By combining \ref{eq:strut\_dynamics\_vec}, \ref{eq:payload\_dynamics} and \ref{eq:generalized\_force}, a single equation describing the dynamics of a flexure jointed hexapod can be found:
|
||||
By combining \eqref{eq:strut\_dynamics\_vec}, \eqref{eq:payload\_dynamics} and \eqref{eq:generalized\_force}, a single equation describing the dynamics of a flexure jointed hexapod can be found:
|
||||
|
||||
\begin{equation}
|
||||
{}^UJ^T [ f\_m - M\_s \ddot{l} - B \dot{l} - K(l - l\_r) - M\_s \ddot{q}\_u - M\_s g\_u + M\_s v\_2] + \mathcal{F}\_e - \begin{bmatrix} mg \\\ 0\_{3\times 1} \end{bmatrix} = M\_x \ddot{\mathcal{X}} + c(\omega) \label{eq:eom\_fjh}
|
||||
@@ -200,7 +200,7 @@ In order to get dominance at low frequencies, the hexapod must be designed so th
|
||||
|
||||
This puts a limit on the rotational stiffness of the flexure joint and shows that as the strut is made softer (by decreasing \\(k\\)), the spherical flexure joint must be made proportionately softer.
|
||||
|
||||
By satisfying \ref{eq:cond\_stiff}, \\(f\_p\\) can be aligned with the strut for frequencies much below the spherical joint's resonance mode:
|
||||
By satisfying \eqref{eq:cond\_stiff}, \\(f\_p\\) can be aligned with the strut for frequencies much below the spherical joint's resonance mode:
|
||||
\\[ \omega \ll \sqrt{\frac{k\_r}{m\_s l^2}} \rightarrow x\_{\text{gain}\_\omega} \approx \frac{k}{k\_r/l^2} \gg 1 \\]
|
||||
At frequencies much above the strut's resonance mode, \\(f\_p\\) is not dominated by its \\(x\\) component:
|
||||
\\[ \omega \gg \sqrt{\frac{k}{m\_s}} \rightarrow x\_{\text{gain}\_\omega} \approx 1 \\]
|
||||
@@ -225,14 +225,14 @@ In this case, it is reasonable to use:
|
||||
|
||||
<div class="important">
|
||||
|
||||
By designing the flexure jointed hexapod and its controller so that both \ref{eq:cond\_stiff} and \ref{eq:cond\_bandwidth} are met, the dynamics of the hexapod can be greatly reduced in complexity.
|
||||
By designing the flexure jointed hexapod and its controller so that both \eqref{eq:cond\_stiff} and \eqref{eq:cond\_bandwidth} are met, the dynamics of the hexapod can be greatly reduced in complexity.
|
||||
|
||||
</div>
|
||||
|
||||
|
||||
## Relationships between joint and cartesian space {#relationships-between-joint-and-cartesian-space}
|
||||
|
||||
Equation \ref{eq:eom\_fjh} is not suitable for control analysis and design because \\(\ddot{\mathcal{X}}\\) is implicitly a function of \\(\ddot{q}\_u\\).
|
||||
Equation \eqref{eq:eom\_fjh} is not suitable for control analysis and design because \\(\ddot{\mathcal{X}}\\) is implicitly a function of \\(\ddot{q}\_u\\).
|
||||
|
||||
This section will derive this implicit relationship.
|
||||
Let denote:
|
||||
|
||||
@@ -53,7 +53,7 @@ In order to provide low frequency passive vibration isolation, the hard actuator
|
||||
<a id="table--tab:mcinroy99-strut-model"></a>
|
||||
<div class="table-caption">
|
||||
<span class="table-number"><a href="#table--tab:mcinroy99-strut-model">Table 1</a>:</span>
|
||||
Definition of quantities on <a href="#orgfe6d4ea">2</a>
|
||||
Definition of quantities on <a href="#orgf3f08ed">2</a>
|
||||
</div>
|
||||
|
||||
| **Symbol** | **Meaning** |
|
||||
@@ -142,7 +142,7 @@ where:
|
||||
- \\(\mathcal{F}\_e\\) represents a vector of exogenous generalized forces applied at the center of mass
|
||||
- \\(g\\) is the gravity vector
|
||||
|
||||
By combining \ref{eq:strut\_dynamics\_vec}, \ref{eq:payload\_dynamics} and \ref{eq:generalized\_force}, a single equation describing the dynamics of a flexure jointed hexapod can be found:
|
||||
By combining \eqref{eq:strut\_dynamics\_vec}, \eqref{eq:payload\_dynamics} and \eqref{eq:generalized\_force}, a single equation describing the dynamics of a flexure jointed hexapod can be found:
|
||||
|
||||
\begin{aligned}
|
||||
& {}^UJ^T [ f\_m - M\_s \ddot{l} - B \dot{l} - K(l - l\_r) - M\_s \ddot{q}\_u\\\\
|
||||
|
||||
@@ -39,14 +39,14 @@ In the frequency range that is relevant for control, the dynamical behavior is m
|
||||
In particular, the mechanics can typically be described as:
|
||||
|
||||
\begin{equation}
|
||||
G\_m = \sum\_{i=1}^{n\_{RB}} \frac{c\_i b\_i^T}{s^2} + \sum\_{n\_{RB} + 1}^{n\_s} \frac{c\_i b\_i^T}{s^2 + 2\xi \omega\_i s + \omega\_i^2}
|
||||
G\_m = \sum\_{i=1}^{n\_{RB}} \frac{c\_i b\_i^T}{s^2} + \sum\_{n\_{RB} + 1}^{n\_s} \frac{c\_i b\_i^T}{s^2 + 2\zeta \omega\_i s + \omega\_i^2}
|
||||
\end{equation}
|
||||
|
||||
where the first term refers to rigid body modes and the second term to flexible modes.
|
||||
|
||||
- \\(n\_{RB}\\) is the number of rigid body modes
|
||||
- \\(c\_i \in \mathbb{R}^{n\_y}\\) and \\(b\_i \in \mathbb{R}^{n\_u}\\) are associated with the mode shapes
|
||||
- \\(\xi\_i, \omega\_i \in \mathbb{R}\_+\\)
|
||||
- \\(\zeta\_i, \omega\_i \in \mathbb{R}\_+\\)
|
||||
|
||||
In traditional positioning systems, the number of actuators \\(n\_u\\) and sensors \\(n\_y\\) equals the number of rigid body modes \\(n\_{RB}\\) and are positioned such that the matrix \\(\sum\_{i=1}^{n\_{RB}} c\_i b\_i^T\\) is invertible.
|
||||
In this case, matrices \\(T\_u\\) and \\(T\_y\\) can be selected such that:
|
||||
|
||||
@@ -100,7 +100,7 @@ The loop must maintain very good frequency response fidelity over wide frequency
|
||||
But a key fact about physical systems is that they do not exhibit good frequency response fidelity beyond a certain bandwidth.
|
||||
This is due to uncertain or unmodeled dynamics in the plant, to digital control implementations, to power limits, to nonlinearities, and to many other factors.
|
||||
Let us call that bandwidth the available bandwidth" \\(\Omega\_a\\), to distinguish it from other bandwidths such as crossover or \\(3-dB\\) magnitude loss.
|
||||
The available bandwidth is the frequency up to which we can keep \\(G(j\omega) K(j\omega)\\) close to a nominal design and beyond which we can only guarantee that the actual loop magnitude will attenuate rapidly enough (e.g. \\(|G(j\omega) K(j\omeg\\))| < δ/ω^2$).
|
||||
The available bandwidth is the frequency up to which we can keep \\(G(j\omega) K(j\omega)\\) close to a nominal design and beyond which we can only guarantee that the actual loop magnitude will attenuate rapidly enough (e.g. \\(|G(j\omega) K(j\omega)| < \delta/\omega^2\\)).
|
||||
In today's popular robust control jargon, the available bandwidth is the frequency range over which the unstructured multiplicative perturbations are substantially less than unity.
|
||||
|
||||
Note that the available bandwidth is not a function of the compensator or of the control design process.
|
||||
|
||||
@@ -80,7 +80,7 @@ The array \\(H(\omega\_i), i = 1 \dots N\_f\\) of complex matrices can be repres
|
||||
|
||||
<div class="important">
|
||||
|
||||
The core result of this paper is that the decomposition can be found by rephrasing \ref{eq:decomposition} as a "Canonical Polyadic Decomposition" (CPD).
|
||||
The core result of this paper is that the decomposition can be found by rephrasing \eqref{eq:decomposition} as a "Canonical Polyadic Decomposition" (CPD).
|
||||
This is shown in [Figure 2](#figure--fig:stoev17-decompos-3d-tensor), where \\(T\_y,T\_u,S\_d\\) can be directly computed using a single Matlab function.
|
||||
|
||||
</div>
|
||||
|
||||
@@ -0,0 +1,4 @@
|
||||
+++
|
||||
title = "Bibliography"
|
||||
build = { render = "never", list = "never" }
|
||||
+++
|
||||
@@ -75,9 +75,9 @@ which includes the resonance model
|
||||
and the resonance \\(P\_{ri}(s)\\) can be represented as one of the following forms
|
||||
|
||||
\begin{align\*}
|
||||
P\_{ri}(s) &= \frac{\omega\_i^2}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2} \\\\
|
||||
P\_{ri}(s) &= \frac{b\_{1i} \omega\_i s + b\_{0i} \omega\_i^2}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2} \\\\
|
||||
P\_{ri}(s) &= \frac{b\_{2i} s^2 + b\_{1i} \omega\_i s + b\_{0i} \omega\_i^2}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2}
|
||||
P\_{ri}(s) &= \frac{\omega\_i^2}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2} \\\\
|
||||
P\_{ri}(s) &= \frac{b\_{1i} \omega\_i s + b\_{0i} \omega\_i^2}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2} \\\\
|
||||
P\_{ri}(s) &= \frac{b\_{2i} s^2 + b\_{1i} \omega\_i s + b\_{0i} \omega\_i^2}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2}
|
||||
\end{align\*}
|
||||
|
||||
|
||||
@@ -98,11 +98,11 @@ There characteristics are shown on [Table 1](#table--tab:microactuator).
|
||||
Performance comparison of microactuators
|
||||
</div>
|
||||
|
||||
| | Elect. | PZT | Thermal |
|
||||
|--------------|-----------------------------------------------|-----------------------------------------------|----------------------------|
|
||||
| TF | \\(\frac{K}{s^2 + 2\xi\omega s + \omega^2}\\) | \\(\frac{K}{s^2 + 2\xi\omega s + \omega^2}\\) | \\(\frac{K}{\tau s + 1}\\) |
|
||||
| \\(\tau\\) | \\(<\SI{0.1}{ms}\\) | \\(<\SI{0.05}{ms}\\) | \\(>\SI{0.1}{ms}\\) |
|
||||
| \\(\omega\\) | \\(1-\SI{2}{kHz}\\) | \\(20-\SI{25}{kHz}\\) | \\(>\SI{15}{kHz}\\) |
|
||||
| | Elect. | PZT | Thermal |
|
||||
|--------------|-------------------------------------------------|-------------------------------------------------|----------------------------|
|
||||
| TF | \\(\frac{K}{s^2 + 2\zeta\omega s + \omega^2}\\) | \\(\frac{K}{s^2 + 2\zeta\omega s + \omega^2}\\) | \\(\frac{K}{\tau s + 1}\\) |
|
||||
| \\(\tau\\) | \\(<\SI{0.1}{ms}\\) | \\(<\SI{0.05}{ms}\\) | \\(>\SI{0.1}{ms}\\) |
|
||||
| \\(\omega\\) | \\(1-\SI{2}{kHz}\\) | \\(20-\SI{25}{kHz}\\) | \\(>\SI{15}{kHz}\\) |
|
||||
|
||||
|
||||
### Single-Stage Actuation Systems {#single-stage-actuation-systems}
|
||||
@@ -210,10 +210,10 @@ Equation means that \\(S(s)\\) can be shaped similarly to the inverse of the cho
|
||||
One form of \\(W(s)\\) is taken as
|
||||
|
||||
\begin{equation}
|
||||
W(s) = \frac{\frac{1}{M}s^2 + 2\xi\omega\frac{1}{\sqrt{M}}s + \omega^2}{s^2 + 2\omega\sqrt{\epsilon}s + \omega^2\epsilon}
|
||||
W(s) = \frac{\frac{1}{M}s^2 + 2\zeta\omega\frac{1}{\sqrt{M}}s + \omega^2}{s^2 + 2\omega\sqrt{\epsilon}s + \omega^2\epsilon}
|
||||
\end{equation}
|
||||
|
||||
where \\(\omega\\) is the desired bandwidth, \\(\epsilon\\) is used to determine the desired low frequency level of sensitivity magnitude and \\(\xi\\) is the damping ratio.
|
||||
where \\(\omega\\) is the desired bandwidth, \\(\epsilon\\) is used to determine the desired low frequency level of sensitivity magnitude and \\(\zeta\\) is the damping ratio.
|
||||
|
||||
The controller can then be synthesis using the linear matrix inequality (LMI) approach.
|
||||
|
||||
|
||||
@@ -221,7 +221,7 @@ This process itself falls into two stages:
|
||||
Most of the effort goes into this second stage, which is widely referred to as "modal parameter extraction", or simply as "modal analysis".
|
||||
|
||||
We have seen that we can predict the form of the FRF plots for a multi degree-of-freedom system, and that these are directly related to the modal properties of that system.
|
||||
The great majority of the modal analysis effort involves **curve-fitting** an expression such as equation \ref{eq:frf\_modal} to the measured FRF and thereby finding the appropriate modal parameters.
|
||||
The great majority of the modal analysis effort involves **curve-fitting** an expression such as equation \eqref{eq:frf\_modal} to the measured FRF and thereby finding the appropriate modal parameters.
|
||||
|
||||
A completely general curve-fitting approach is possible but generally inefficient.
|
||||
Mathematically, we can take an equation of the form
|
||||
@@ -379,14 +379,14 @@ which leads to
|
||||
|
||||
\begin{align}
|
||||
s\_{1, 2} &= -\frac{c}{2 m} \pm \frac{\sqrt{c^2 - 4 k m}}{2 m} \\\\
|
||||
&= - \bar{\omega}\_0 \xi \pm i \bar{\omega}\_0 \sqrt{1 - \xi^2} \nonumber
|
||||
&= - \bar{\omega}\_0 \zeta \pm i \bar{\omega}\_0 \sqrt{1 - \zeta^2} \nonumber
|
||||
\end{align}
|
||||
|
||||
where
|
||||
\\[ \bar{\omega}\_0^2 = \frac{k}{m};\quad \xi = \frac{c}{c\_0} = \frac{c}{2 \sqrt{km}} \\]
|
||||
\\[ \bar{\omega}\_0^2 = \frac{k}{m};\quad \zeta = \frac{c}{c\_0} = \frac{c}{2 \sqrt{km}} \\]
|
||||
|
||||
This implies a modal solution of the form
|
||||
\\[ x(t) = X e^{-\bar{\omega}\_0 \xi t} e^{i (\bar{\omega}\_0 \sqrt{1 - \xi^2})t} = X e^{-a t} e^{i \omega\_0^\prime t} \\]
|
||||
\\[ x(t) = X e^{-\bar{\omega}\_0 \zeta t} e^{i (\bar{\omega}\_0 \sqrt{1 - \zeta^2})t} = X e^{-a t} e^{i \omega\_0^\prime t} \\]
|
||||
which is a single mode of vibration with a complex natural frequency having two part:
|
||||
|
||||
- **An imaginary or oscillatory part**
|
||||
@@ -485,11 +485,11 @@ where \\(\eta\\) is the **structural damping loss factor** and replaces the crit
|
||||
|
||||
#### Alternative Forms of FRF {#alternative-forms-of-frf}
|
||||
|
||||
So far we have defined our receptance frequency response function \\(\alpha(\omega)\\) as the ratio between a harmonic displacement response and the harmonic force \ref{eq:receptance}.
|
||||
So far we have defined our receptance frequency response function \\(\alpha(\omega)\\) as the ratio between a harmonic displacement response and the harmonic force \eqref{eq:receptance}.
|
||||
This ratio is complex: we can look at its **amplitude** ratio \\(|\alpha(\omega)|\\) and its **phase** angle \\(\theta\_\alpha(\omega)\\).
|
||||
|
||||
We could have selected the response velocity \\(v(t)\\) as the output quantity and defined an alternative frequency response function \ref{eq:mobility}.
|
||||
Similarly we could use the acceleration parameter so we could define a third FRF parameter \ref{eq:inertance}.
|
||||
We could have selected the response velocity \\(v(t)\\) as the output quantity and defined an alternative frequency response function \eqref{eq:mobility}.
|
||||
Similarly we could use the acceleration parameter so we could define a third FRF parameter \eqref{eq:inertance}.
|
||||
|
||||
<div class="definition">
|
||||
|
||||
@@ -608,7 +608,7 @@ This type of display is not widely used as we cannot use logarithmic axes (as we
|
||||
|
||||
##### Real part and Imaginary part of reciprocal FRF {#real-part-and-imaginary-part-of-reciprocal-frf}
|
||||
|
||||
It can be seen from the expression of the inverse receptance \ref{eq:dynamic\_stiffness} that the Real part depends entirely on the mass and stiffness properties while the Imaginary part is a only function of the damping.
|
||||
It can be seen from the expression of the inverse receptance \eqref{eq:dynamic\_stiffness} that the Real part depends entirely on the mass and stiffness properties while the Imaginary part is a only function of the damping.
|
||||
|
||||
[Figure 9a](#org-target--fig-inverse-frf-mixed) shows an example of a plot of a system with a combination of both viscous and structural damping. The imaginary part is a straight line whose slope is given by the viscous damping rate \\(c\\) and whose intercept at \\(\omega = 0\\) is provided by the structural damping coefficient \\(d\\).
|
||||
|
||||
@@ -657,7 +657,7 @@ This makes the Nyquist plot very effective for modal testing applications.
|
||||
|
||||
#### Free Vibration Solution - The modal Properties {#free-vibration-solution-the-modal-properties}
|
||||
|
||||
For an undamped MDOF system, with \\(N\\) degrees of freedom, the governing equations of motion can be written in matrix form \ref{eq:undamped\_mdof}.
|
||||
For an undamped MDOF system, with \\(N\\) degrees of freedom, the governing equations of motion can be written in matrix form \eqref{eq:undamped\_mdof}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -673,7 +673,7 @@ where \\([M]\\) and \\([K]\\) are \\(N\times N\\) mass and stiffness matrices, a
|
||||
|
||||
We shall consider first the free vibration solution by taking \\(f(t) = 0\\).
|
||||
In this case, we assume that a solution exists of the form \\(\\{x(t)\\} = \\{X\\} e^{i \omega t}\\) where \\(\\{X\\}\\) is an \\(N \times 1\\) vector of time-independent amplitudes.
|
||||
Substitution of this condition into \ref{eq:undamped\_mdof} leads to
|
||||
Substitution of this condition into \eqref{eq:undamped\_mdof} leads to
|
||||
|
||||
\begin{equation} \label{eq:free\_eom\_mdof}
|
||||
\left( [K] - \omega^2 [M] \right) \\{X\\} e^{i\omega t} = \\{0\\}
|
||||
@@ -683,7 +683,7 @@ for which the non trivial solutions are those which satisfy
|
||||
\\[ \det \left| [K] - \omega^2 [M] \right| = 0 \\]
|
||||
from which we can find \\(N\\) values of \\(\omega^2\\) corresponding to the undamped system's **natural frequencies**.
|
||||
|
||||
Substituting any of these back into \ref{eq:free\_eom\_mdof} yields a corresponding set of relative values for \\(\\{X\\}\\): \\(\\{\psi\\}\_r\\) the so-called **mode shape** corresponding to that natural frequency.
|
||||
Substituting any of these back into \eqref{eq:free\_eom\_mdof} yields a corresponding set of relative values for \\(\\{X\\}\\): \\(\\{\psi\\}\_r\\) the so-called **mode shape** corresponding to that natural frequency.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -820,7 +820,7 @@ An alternative means of deriving the FRF parameters is used which makes use of t
|
||||
\\[ [K] - \omega^2 [M] = [\alpha(\omega)]^{-1} \\]
|
||||
Pre-multiply both sides by \\([\Phi]^T\\) and post-multiply both sides by \\([\Phi]\\) to obtain
|
||||
\\[ [\Phi]^T ([K] - \omega^2 [M]) [\Phi] = [\Phi]^T [\alpha(\omega)]^{-1} [\Phi] \\]
|
||||
which leads to \ref{eq:receptance\_modal}.
|
||||
which leads to \eqref{eq:receptance\_modal}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -830,7 +830,7 @@ Receptance FRF matrix - Modal Properties;
|
||||
[\alpha(\omega)] = [\Phi] \left[ \bar{\omega}\_r^2 - \omega^2 \right]^{-1} [\Phi]^T \label{eq:receptance\_modal}
|
||||
\end{equation}
|
||||
|
||||
Equation \ref{eq:receptance\_modal} permits us to compute any individual FRF parameters \\(\alpha\_{jk}(\omega)\\) using the following formula
|
||||
Equation \eqref{eq:receptance\_modal} permits us to compute any individual FRF parameters \\(\alpha\_{jk}(\omega)\\) using the following formula
|
||||
|
||||
\begin{align}
|
||||
\alpha\_{jk}(\omega) &= \sum\_{r=1}^N \frac{\phi\_{jr} \phi\_{kr}}{\bar{\omega}\_r^2 - \omega^2}\\\\
|
||||
@@ -844,7 +844,7 @@ where \\({}\_rA\_{jk}\\) is called the **modal constant**.
|
||||
|
||||
<div class="important">
|
||||
|
||||
It is clear from equation \ref{eq:receptance\_modal} that the receptance matrix \\([\alpha(\omega)]\\) is **symmetric** and this will be recognized as the **principle of reciprocity**.
|
||||
It is clear from equation \eqref{eq:receptance\_modal} that the receptance matrix \\([\alpha(\omega)]\\) is **symmetric** and this will be recognized as the **principle of reciprocity**.
|
||||
|
||||
This principle of reciprocity applies to many structural characteristics.
|
||||
|
||||
@@ -899,7 +899,7 @@ A usual definition of proportional damping is that the damping matrix \\([C]\\)
|
||||
In this case, the damped system will have eigenvalues and eigenvectors as follows
|
||||
|
||||
\begin{align\*}
|
||||
&\omega\_r^\prime = \bar{\omega}\_r \sqrt{1 - \xi\_r^2} ; \quad \xi\_r = \frac{\beta \bar{\omega}\_r}{2} + \frac{\gamma}{2 \bar{\omega}\_r}\\\\
|
||||
&\omega\_r^\prime = \bar{\omega}\_r \sqrt{1 - \zeta\_r^2} ; \quad \zeta\_r = \frac{\beta \bar{\omega}\_r}{2} + \frac{\gamma}{2 \bar{\omega}\_r}\\\\
|
||||
&[\Psi\_\text{damped}] = [\Psi\_\text{undamped}]
|
||||
\end{align\*}
|
||||
|
||||
@@ -982,7 +982,7 @@ From this full matrix equation, we have:
|
||||
|
||||
Having derived an expression for the general term in the frequency response function matrix \\(\alpha\_{jk}(\omega)\\), it is appropriate to consider next the analysis of a situation where the system is **excited simultaneously at several points**.
|
||||
|
||||
The general behavior for this case is governed by equation \ref{eq:force\_response\_eom} with solution \ref{eq:force\_response\_eom\_solution}.
|
||||
The general behavior for this case is governed by equation \eqref{eq:force\_response\_eom} with solution \eqref{eq:force\_response\_eom\_solution}.
|
||||
However, a more explicit form of the solution is
|
||||
|
||||
\begin{equation} \label{eq:ods}
|
||||
@@ -1005,7 +1005,7 @@ The properties of the normal modes of the undamped system are of interest becaus
|
||||
|
||||
</div>
|
||||
|
||||
We are seeking an excitation vector \\(\\{F\\}\\) such that the **response** \\(\\{X\\}\\) **consists of a single modal component** so that all terms in \ref{eq:ods} but one is zero.
|
||||
We are seeking an excitation vector \\(\\{F\\}\\) such that the **response** \\(\\{X\\}\\) **consists of a single modal component** so that all terms in \eqref{eq:ods} but one is zero.
|
||||
This can be attained if \\(\\{F\\}\\) is chosen such that
|
||||
\\[ \\{\phi\_r\\}^T \\{F\\}\_s = 0, \ r \neq s \\]
|
||||
|
||||
@@ -1074,8 +1074,8 @@ The eigensolution can thus be described as
|
||||
\\[ s\_r, s\_r^\*, \quad \\{\psi\\}\_r, \\{\psi\\}\_r^\*;\quad r = 1, N \\]
|
||||
|
||||
Each eigenvalue \\(s\_r\\) is expressed in the form
|
||||
\\[ s\_r = \omega\_r \left( -\xi\_r + i\sqrt{1 - \xi\_r^2} \right) \\]
|
||||
where \\(\omega\_r\\) is the **natural frequency** and \\(\xi\_r\\) is the **critical damping ratio** for that mode.
|
||||
\\[ s\_r = \omega\_r \left( -\zeta\_r + i\sqrt{1 - \zeta\_r^2} \right) \\]
|
||||
where \\(\omega\_r\\) is the **natural frequency** and \\(\zeta\_r\\) is the **critical damping ratio** for that mode.
|
||||
|
||||
**Orthogonality equations** can also be derived:
|
||||
|
||||
@@ -1085,12 +1085,12 @@ where \\(\omega\_r\\) is the **natural frequency** and \\(\xi\_r\\) is the **cri
|
||||
\end{align}
|
||||
|
||||
When the modes \\(r\\) and \\(q\\) are a complex conjugate pair:
|
||||
\\[ s\_r = \omega\_r \left( -\xi\_r - i\sqrt{1 - \xi\_r^2} \right); \quad \\{\psi\\}\_q = \\{\psi\\}\_r^\* \\]
|
||||
\\[ s\_r = \omega\_r \left( -\zeta\_r - i\sqrt{1 - \zeta\_r^2} \right); \quad \\{\psi\\}\_q = \\{\psi\\}\_r^\* \\]
|
||||
|
||||
From equations \ref{eq:viscous\_damping\_orthogonality}, we can obtain
|
||||
From equations \eqref{eq:viscous\_damping\_orthogonality}, we can obtain
|
||||
|
||||
\begin{align}
|
||||
2 \omega\_r \xi\_r &= \frac{\\{\psi\\}\_r^H [C] \\{\psi\\}\_r}{\\{\psi\\}\_r^H [M] \\{\psi\\}\_r} = \frac{c\_r}{m\_r} \\\\
|
||||
2 \omega\_r \zeta\_r &= \frac{\\{\psi\\}\_r^H [C] \\{\psi\\}\_r}{\\{\psi\\}\_r^H [M] \\{\psi\\}\_r} = \frac{c\_r}{m\_r} \\\\
|
||||
\omega\_r^2 &= \frac{\\{\psi\\}\_r^H [K] \\{\psi\\}\_r}{\\{\psi\\}\_r^H [M] \\{\psi\\}\_r} = \frac{k\_r}{m\_r}
|
||||
\end{align}
|
||||
|
||||
@@ -1104,11 +1104,11 @@ but this expression is not particularly convenient for numerical applications.
|
||||
We then seek a similar series expansion that was found for the undamped, proportionally-damped and hysteretically damped systems.
|
||||
|
||||
The obtain result is
|
||||
\\[ \alpha\_{jk}(\omega) = \sum\_{r=1}^N \frac{({}\_rR\_{jk}) + i (\omega/\omega\_r)({}\_rS\_{jk})}{\omega\_r^2 - \omega^2 + 2 i \omega \omega\_r \xi\_r} \\]
|
||||
\\[ \alpha\_{jk}(\omega) = \sum\_{r=1}^N \frac{({}\_rR\_{jk}) + i (\omega/\omega\_r)({}\_rS\_{jk})}{\omega\_r^2 - \omega^2 + 2 i \omega \omega\_r \zeta\_r} \\]
|
||||
where the coefficients \\(R\\) and \\(S\\) are obtained from:
|
||||
|
||||
\begin{align\*}
|
||||
\\{{}\_rR\_k\\} &= 2 \left( \xi\_r \text{Re}\\{{}\_rG\_k\\} - \text{Im}\\{{}\_rG\_k\\} \sqrt{1 - \xi\_r^2} \right)\\\\
|
||||
\\{{}\_rR\_k\\} &= 2 \left( \zeta\_r \text{Re}\\{{}\_rG\_k\\} - \text{Im}\\{{}\_rG\_k\\} \sqrt{1 - \zeta\_r^2} \right)\\\\
|
||||
\\{{}\_rS\_k\\} &= 2 \text{Re}\\{{}\_rG\_k\\}\\\\
|
||||
\\{{}\_rG\_k\\} &= (\theta\_{kr}/a\_r) \\{\theta\\}\_r
|
||||
\end{align\*}
|
||||
@@ -1221,13 +1221,13 @@ Here \\(C\_r\\) may be complex whereas \\(D\_r\\) is real.
|
||||
FRF Formulae and Natural Frequencies
|
||||
</div>
|
||||
|
||||
| **Case** | **C** | **D** | **Free** \\(\omega\_r^\prime\\) | **Forced** \\(\omega\_r\\) |
|
||||
|-------------|---------------------------------|---------------------------------|----------------------------------|----------------------------|
|
||||
| Undamped | \\(\mathbb{R}\\) | 0 | \\(\bar{\omega}\_r\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Prop. Hyst. | \\(\mathbb{R}\\) | \\(\mathbb{R}\\) | \\(\bar{\omega}\_r\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Prop. Visc. | \\(\mathbb{R}\\) | \\(\mathbb{R}\\) (\\(\omega\\)) | \\(\omega\_r\sqrt{1-\xi\_r^2}\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Gen. Hyst. | \\(\mathbb{C}\\) | \\(\mathbb{R}\\) | \\(\omega\_r\\) | \\(\omega\_r\\) |
|
||||
| Gen. Visc. | \\(\mathbb{C}\\) (\\(\omega\\)) | \\(\mathbb{R}\\) (\\(\omega\\)) | \\(\omega\_r\sqrt{1-\xi\_r^2}\\) | \\(\omega\_r\\) |
|
||||
| **Case** | **C** | **D** | **Free** \\(\omega\_r^\prime\\) | **Forced** \\(\omega\_r\\) |
|
||||
|-------------|---------------------------------|---------------------------------|------------------------------------|----------------------------|
|
||||
| Undamped | \\(\mathbb{R}\\) | 0 | \\(\bar{\omega}\_r\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Prop. Hyst. | \\(\mathbb{R}\\) | \\(\mathbb{R}\\) | \\(\bar{\omega}\_r\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Prop. Visc. | \\(\mathbb{R}\\) | \\(\mathbb{R}\\) (\\(\omega\\)) | \\(\omega\_r\sqrt{1-\zeta\_r^2}\\) | \\(\bar{\omega}\_r\\) |
|
||||
| Gen. Hyst. | \\(\mathbb{C}\\) | \\(\mathbb{R}\\) | \\(\omega\_r\\) | \\(\omega\_r\\) |
|
||||
| Gen. Visc. | \\(\mathbb{C}\\) (\\(\omega\\)) | \\(\mathbb{R}\\) (\\(\omega\\)) | \\(\omega\_r\sqrt{1-\zeta\_r^2}\\) | \\(\omega\_r\\) |
|
||||
|
||||
|
||||
#### Mobility and Impedance FRF Parameters {#mobility-and-impedance-frf-parameters}
|
||||
@@ -1400,7 +1400,7 @@ One these two series are available, the FRF can be defined at the same set of fr
|
||||
|
||||
##### Analysis via Fourier transform {#analysis-via-fourier-transform}
|
||||
|
||||
For most transient cases, the input function \\(f(t)\\) will satisfy the **Dirichlet condition** and so its Fourier Transform \\(F(\omega)\\) can be computed from \ref{eq:fourier\_transform}.
|
||||
For most transient cases, the input function \\(f(t)\\) will satisfy the **Dirichlet condition** and so its Fourier Transform \\(F(\omega)\\) can be computed from \eqref{eq:fourier\_transform}.
|
||||
|
||||
\begin{equation} \label{eq:fourier\_transform}
|
||||
F(\omega) = \frac{1}{2 \pi} \int\_{-\infty}^\infty f(t) e^{i\omega t} dt
|
||||
@@ -1556,10 +1556,10 @@ However, the same equation can be transform to the frequency domain
|
||||
\tcmbox{ S\_{xx}(\omega) = \left| H(\omega) \right|^2 S\_{ff}(\omega) }
|
||||
\end{equation}
|
||||
|
||||
Although very convenient, equation \ref{eq:psd\_input\_output} does not provide a complete description of the random vibration conditions.
|
||||
Although very convenient, equation \eqref{eq:psd\_input\_output} does not provide a complete description of the random vibration conditions.
|
||||
Further, it is clear that **is could not be used to determine the FRF** from measurement of excitation and response because it **contains only the modulus** of \\(H(\omega)\\), the phase information begin omitted from this formula.
|
||||
|
||||
A second equation is required and this may be obtain by a similar analysis, two alternative formulas can be obtained \ref{eq:cross\_relation\_alternatives}.
|
||||
A second equation is required and this may be obtain by a similar analysis, two alternative formulas can be obtained \eqref{eq:cross\_relation\_alternatives}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1573,8 +1573,8 @@ A second equation is required and this may be obtain by a similar analysis, two
|
||||
|
||||
##### To derive FRF from random vibration signals {#to-derive-frf-from-random-vibration-signals}
|
||||
|
||||
The pair of equations \ref{eq:cross\_relation\_alternatives} provides the basic of determining a system's FRF properties from the measurements and analysis of a random vibration test.
|
||||
Using either of them, we have a simple formula for determining the FRF from estimates of the relevant spectral densities \ref{eq:H1} \ref{eq:H2}.
|
||||
The pair of equations \eqref{eq:cross\_relation\_alternatives} provides the basic of determining a system's FRF properties from the measurements and analysis of a random vibration test.
|
||||
Using either of them, we have a simple formula for determining the FRF from estimates of the relevant spectral densities \eqref{eq:H1} \eqref{eq:H2}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1615,7 +1615,7 @@ Then in [Figure 18b](#org-target--fig-frf-feedback-model) is given a more detail
|
||||
</figure>
|
||||
|
||||
In this configuration, it can be seen that there are two feedback mechanisms which apply.
|
||||
We then introduce an alternative formula which is available for the determination of the system FRF from measurements of the input and output quantities \ref{eq:H3}.
|
||||
We then introduce an alternative formula which is available for the determination of the system FRF from measurements of the input and output quantities \eqref{eq:H3}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1754,7 +1754,7 @@ First, if we have a **modal incompleteness** (\\(m<N\\) modes included), then we
|
||||
|
||||
However, if we have **spatial incompleteness** (only \\(n<N\\) DOFs included), then we cannot express any orthogonality properties at all because the eigenvector matrix is not commutable with the system mass and stiffness matrices.
|
||||
|
||||
In both reduced-model cases, it is not possible to use equation \ref{eq:spatial\_model\_from\_modal} to re-construct the system mass and stiffness matrices.
|
||||
In both reduced-model cases, it is not possible to use equation \eqref{eq:spatial\_model\_from\_modal} to re-construct the system mass and stiffness matrices.
|
||||
First of all because the eigen matrices are generally singular and even if it is not, the obtained mass and stiffness matrices produced have no physical significance and should not be used.
|
||||
|
||||
|
||||
@@ -2288,9 +2288,7 @@ The process of filtering has a direct parallel with windowing.
|
||||
Common filters are: low-pass, high-pass, band-limited, narrow-band, notch.
|
||||
|
||||
|
||||
#### Improving Resolution {#improving-resolution}
|
||||
|
||||
<span class="org-target" id="org-target--sec-improving-resolution"></span>
|
||||
#### Improving Resolution {#sec:improving_resolution}
|
||||
|
||||
|
||||
##### Increasing transform size {#increasing-transform-size}
|
||||
@@ -2783,7 +2781,7 @@ Then, the full \\(6 \times 6\\) mobility matrix can be measured, however this pr
|
||||
Other methods for measuring rotational effects include specially developed rotational accelerometers and shakers.
|
||||
|
||||
However, there is a major problem that is encountered when measuring rotational FRF: the translational components of the structure's movement tends to overshadow those due to the rotational motions.
|
||||
For example, the magnitude of the difference in equation \ref{eq:rotational\_diff} is often of the order of \\(\SI{1}{\\%}\\) of the two individual values which is similar to the transverse sensitivity of the accelerometers: potential errors in rotations are thus enormous.
|
||||
For example, the magnitude of the difference in equation \eqref{eq:rotational\_diff} is often of the order of \\(\SI{1}{\\%}\\) of the two individual values which is similar to the transverse sensitivity of the accelerometers: potential errors in rotations are thus enormous.
|
||||
|
||||
|
||||
### Multi-point excitation methods {#multi-point-excitation-methods}
|
||||
@@ -2822,7 +2820,7 @@ The two vectors are related by the system's FRF properties as:
|
||||
\\{X\\}\_{n\times 1} = [H(\omega)]\_{n\times p} \\{F\\}\_{p\times 1}
|
||||
\end{equation}
|
||||
|
||||
However, it is not possible to derive the FRF matrix from the single equation \ref{eq:mpss\_equation}, because there will be insufficient data in the two vectors (one of length \\(p\\), the other of length \\(n\\)) to define completely the \\(n\times p\\) FRF matrix.
|
||||
However, it is not possible to derive the FRF matrix from the single equation \eqref{eq:mpss\_equation}, because there will be insufficient data in the two vectors (one of length \\(p\\), the other of length \\(n\\)) to define completely the \\(n\times p\\) FRF matrix.
|
||||
|
||||
What is required is to make a series of \\(p^\prime\\) measurements of the same basic type using different excitation vectors \\(\\{F\\}\_i\\) that should be chosen such that the forcing matrix \\([F]\_{p\times p^\prime} = [\\{F\\}\_1, \dots, \\{F\\}\_p]\\) is non-singular.
|
||||
This can be assured if:
|
||||
@@ -3267,7 +3265,7 @@ The peak-picking method is applied as follows (illustrated on [Figure 46](#figur
|
||||
\begin{equation}
|
||||
\begin{aligned}
|
||||
\eta\_r &= \frac{\omega\_a^2 - \omega\_b^2}{2 \omega\_r^2} \approx \frac{\Delta\omega}{\omega\_r} \\\\
|
||||
2\xi\_r &= \eta\_r
|
||||
2\zeta\_r &= \eta\_r
|
||||
\end{aligned}
|
||||
\end{equation}
|
||||
4. We now obtain an estimate for the **modal constant** of the mode being analyzed by assuming that the total response in this resonant region is attributed to a single term in the general FRF series:
|
||||
@@ -3330,13 +3328,13 @@ For any frequency \\(\omega\\), we have the following relationship:
|
||||
\end{aligned}
|
||||
\end{equation}
|
||||
|
||||
From \ref{eq:modal\_circle\_tan}, we obtain:
|
||||
From \eqref{eq:modal\_circle\_tan}, we obtain:
|
||||
|
||||
\begin{equation} \label{eq:modal\_circle\_omega}
|
||||
\omega^2 = \omega\_r^2 \left(1 - \eta\_r \tan\left(\frac{\theta}{2}\right) \right)
|
||||
\end{equation}
|
||||
|
||||
If we differentiate \ref{eq:modal\_circle\_omega} with respect to \\(\theta\\), we obtain:
|
||||
If we differentiate \eqref{eq:modal\_circle\_omega} with respect to \\(\theta\\), we obtain:
|
||||
|
||||
\begin{equation}
|
||||
\frac{d\omega^2}{d\theta} = \frac{-\omega\_r^2 \eta\_r}{2} \frac{\left(1 - (\omega/\omega\_r)^2\right)^2}{\eta\_r^2}
|
||||
@@ -3392,14 +3390,14 @@ For SDOF system with **viscous** damping, rather than structural damping, the **
|
||||
And we have
|
||||
|
||||
\begin{equation}
|
||||
\tan\left(\frac{\theta}{2}\right) = \frac{1 - (\omega/\omega\_r)^2}{2 \xi \omega/\omega\_r}
|
||||
\tan\left(\frac{\theta}{2}\right) = \frac{1 - (\omega/\omega\_r)^2}{2 \zeta \omega/\omega\_r}
|
||||
\end{equation}
|
||||
|
||||
From points at \\(\omega\_a\\) and \\(\omega\_b\\), we obtain
|
||||
|
||||
\begin{equation}
|
||||
\begin{aligned}
|
||||
\xi &= \frac{\omega\_a^2 - \omega\_b^2}{2 \omega\_r \left( \omega\_a \tan(\theta\_a/2) + \omega\_b \tan(\theta\_b/2) \right)}\\\\
|
||||
\zeta &= \frac{\omega\_a^2 - \omega\_b^2}{2 \omega\_r \left( \omega\_a \tan(\theta\_a/2) + \omega\_b \tan(\theta\_b/2) \right)}\\\\
|
||||
&= \frac{\omega\_a - \omega\_b}{\omega\_r \left( \tan(\theta\_a/2) + \tan(\theta\_b/2) \right)} \text{ for light damping}
|
||||
\end{aligned}
|
||||
\end{equation}
|
||||
@@ -3407,7 +3405,7 @@ From points at \\(\omega\_a\\) and \\(\omega\_b\\), we obtain
|
||||
Finally, selecting two points for which \\(\theta\_a = \theta\_b = \SI{90}{\degree}\\):
|
||||
|
||||
\begin{equation}
|
||||
\xi = \frac{\omega\_2 - \omega\_1}{2 \omega\_r}
|
||||
\zeta = \frac{\omega\_2 - \omega\_1}{2 \omega\_r}
|
||||
\end{equation}
|
||||
|
||||
|
||||
@@ -3421,10 +3419,10 @@ The sequence is:
|
||||
Then we obtain the **center** and **radius** of the circle and the **quality factor** is the mean square deviation of the chosen points from the circle.
|
||||
3. **Locate natural frequency, obtain damping estimate**.
|
||||
The rate of sweep through the region is estimated numerically and the frequency at which it reaches the maximum is deduced.
|
||||
At the same time, an estimate of the damping is derived using \ref{eq:estimate\_damping\_sweep\_rate}.
|
||||
At the same time, an estimate of the damping is derived using \eqref{eq:estimate\_damping\_sweep\_rate}.
|
||||
A typical example is shown on [Figure 48](#figure--fig:circle-fit-natural-frequency).
|
||||
4. **Calculate multiple damping estimates, and scatter**.
|
||||
A set of damping estimates using all possible combination of the selected data points are computed using \ref{eq:estimate\_damping}.
|
||||
A set of damping estimates using all possible combination of the selected data points are computed using \eqref{eq:estimate\_damping}.
|
||||
Then, we can choose the damping estimate to be the mean value.
|
||||
We also look at the distribution of the obtained damping estimates as is permits a useful diagnostic of the quality of the entire analysis:
|
||||
- Good measured data should lead to a smooth plot of these damping estimates, any roughness of the surface can be explained in terms of noise in the original data.
|
||||
@@ -3530,7 +3528,7 @@ we now have sufficient information to extract estimates for the four parameters
|
||||
|
||||
3. Plot graphs of \\(m\_R(\Omega)\\) vs \\(\Omega^2\\) and of \\(m\_I(\Omega)\\) vs \\(\Omega^2\\) using the results from step 1., each time using a different measurement points as the fixing frequency \\(\Omega\_j\\)
|
||||
4. Determine the slopes of the best fit straight lines through these two plots, \\(n\_R\\) and \\(n\_I\\), and their intercepts with the vertical axis \\(d\_R\\) and \\(d\_I\\)
|
||||
5. Use these four quantities, and equation \ref{eq:modal\_parameters\_formula}, to determine the **four modal parameters** required for that mode
|
||||
5. Use these four quantities, and equation \eqref{eq:modal\_parameters\_formula}, to determine the **four modal parameters** required for that mode
|
||||
|
||||
This procedure which places more weight to points slightly away from the resonance region is likely to be less sensitive to measurement difficulties of measuring the resonance region.
|
||||
|
||||
@@ -3599,7 +3597,7 @@ From the sketch, it may be seen that within the frequency range of interest:
|
||||
- the first term tends to approximate to a **mass-like behavior**
|
||||
- the third term approximates to a **stiffness effect**
|
||||
|
||||
Thus, we have a basis for the residual terms and shall rewrite equation \ref{eq:sum\_modes:}
|
||||
Thus, we have a basis for the residual terms and shall rewrite equation \eqref{eq:sum\_modes:}
|
||||
|
||||
\begin{equation}
|
||||
H\_{jk}(\omega) \simeq -\frac{1}{\omega^2 M\_{jk}^R} + \sum\_{r=m\_1}^{m\_2} \left( \frac{{}\_rA\_{jk}}{\omega\_r^2 - \omega^2 + i \eta\_r \omega\_r^2} \right) + \frac{1}{K\_{jk}^R}
|
||||
@@ -3659,7 +3657,7 @@ We can write the receptance in the frequency range of interest as:
|
||||
|
||||
In the previous methods, the second term was assumed to be a constant in the curve-fit procedure for mode \\(r\\).
|
||||
However, if we have good **estimates** for the coefficients which constitutes the second term, for example by having already completed an SDOF analysis, we may remove the restriction on the analysis.
|
||||
Indeed, suppose we take a set of measured data points around the resonance at \\(\omega\_r\\), and that we can compute the magnitude of the second term in \ref{eq:second\_term\_refinement}, we then subtract this from the measurement and we obtain adjusted data points that are conform to a true SDOF behavior and we can use the same technique as before to obtain **improved estimated** to the modal parameters of more \\(r\\).
|
||||
Indeed, suppose we take a set of measured data points around the resonance at \\(\omega\_r\\), and that we can compute the magnitude of the second term in \eqref{eq:second\_term\_refinement}, we then subtract this from the measurement and we obtain adjusted data points that are conform to a true SDOF behavior and we can use the same technique as before to obtain **improved estimated** to the modal parameters of more \\(r\\).
|
||||
|
||||
This procedure can be repeated iteratively for all the modes in the range of interest and it can significantly enhance the quality of found modal parameters for system with **strong coupling**.
|
||||
|
||||
@@ -3718,7 +3716,7 @@ If we further increase the generality by attaching a **weighting factor** \\(w\_
|
||||
|
||||
is minimized.
|
||||
|
||||
This is achieved by differentiating \ref{eq:error\_weighted} with respect to each unknown in turn, thus generating a set of as many equations as there are unknown:
|
||||
This is achieved by differentiating \eqref{eq:error\_weighted} with respect to each unknown in turn, thus generating a set of as many equations as there are unknown:
|
||||
|
||||
\begin{equation}
|
||||
\frac{d E}{d q} = 0; \quad q = {}\_1A\_{jk}, {}\_2A\_{jk}, \dots
|
||||
@@ -3738,7 +3736,7 @@ This method is a special version of the general curve fitting approach but is ba
|
||||
Rational fraction FRF formulation:
|
||||
|
||||
\begin{equation}
|
||||
H(\omega) = \sum\_{r=1}^N \frac{A\_r}{\omega\_r^2 - \omega^2 + 2 i \omega \omega\_r \xi\_r} \label{eq:frf\_clasic}
|
||||
H(\omega) = \sum\_{r=1}^N \frac{A\_r}{\omega\_r^2 - \omega^2 + 2 i \omega \omega\_r \zeta\_r} \label{eq:frf\_clasic}
|
||||
\end{equation}
|
||||
|
||||
\begin{equation}
|
||||
@@ -3769,7 +3767,7 @@ leading to the modified, but more convenient version actually used in the analys
|
||||
\end{equation}
|
||||
|
||||
In these expressions, only \\(m\\) modes are included in the theoretical FRF formula: the true number of modes, \\(N\\), is actually one of the **unknowns** to be determined during the analysis.
|
||||
Equation \ref{eq:rpf\_error} can be rewritten as follows:
|
||||
Equation \eqref{eq:rpf\_error} can be rewritten as follows:
|
||||
|
||||
\begin{equation}
|
||||
\begin{aligned}
|
||||
@@ -3823,9 +3821,9 @@ where \\([X], [Y], [Z], \\{G\\}\\) and \\(\\{F\\}\\) are known measured quantiti
|
||||
\end{equation}
|
||||
|
||||
Once the solution has been obtained for the coefficients \\(a\_k, \dots , b\_k, \dots\\) then the second stage of the modal analysis can be performed in which the required **modal parameters are derived**.
|
||||
This is usually done by solving the two polynomial expressions which form the numerator and denominator of equations \ref{eq:frf\_clasic} and \ref{eq:frf\_rational:}
|
||||
This is usually done by solving the two polynomial expressions which form the numerator and denominator of equations \eqref{eq:frf\_clasic} and \eqref{eq:frf\_rational:}
|
||||
|
||||
- the denominator is used to obtain the natural frequencies \\(\omega\_r\\) and damping factors \\(\xi\_r\\)
|
||||
- the denominator is used to obtain the natural frequencies \\(\omega\_r\\) and damping factors \\(\zeta\_r\\)
|
||||
- the numerator is used to determine the complex modal constants \\(A\_r\\)
|
||||
|
||||
In order to determine the order, the analysis is repeated using different assumed values for the order \\(m\\) and are compared.
|
||||
@@ -4055,7 +4053,7 @@ First, we note that from a single FRF curve, \\(H\_{jk}(\omega)\\), it is possib
|
||||
|
||||
Now, although this gives us the natural frequency and damping properties directly, it does not explicitly yield the mode shape: only a modal constant \\({}\_rA\_{jk}\\) which is formed from the mode shape data.
|
||||
In order to extract the individual elements \\(\phi\_{jr}\\) of the mode shape matrix \\([\Phi]\\), it is necessary to make a series of measurements of specific FRFs including, especially, the point FRF at the excitation position.
|
||||
If we measure \\(H\_{kk}\\), then by using \ref{eq:modal\_model\_from\_frf}, we also obtain the specific elements in the mode shape matrix corresponding to the excitation point:
|
||||
If we measure \\(H\_{kk}\\), then by using \eqref{eq:modal\_model\_from\_frf}, we also obtain the specific elements in the mode shape matrix corresponding to the excitation point:
|
||||
|
||||
\begin{equation}
|
||||
H\_{kk}(\omega) \longrightarrow \omega\_r, \eta\_r, {}\_rA\_{jk} \longrightarrow \phi\_{kr}; \quad r=1, m
|
||||
@@ -4529,7 +4527,7 @@ In this respect, the demands of the response model are more stringent that those
|
||||
|
||||
#### Synthesis of FRF curves {#synthesis-of-frf-curves}
|
||||
|
||||
One of the implications of equation \ref{eq:regenerate\_full\_frf\_matrix} is that **it is possible to synthesize the FRF curves which were not measured**.
|
||||
One of the implications of equation \eqref{eq:regenerate\_full\_frf\_matrix} is that **it is possible to synthesize the FRF curves which were not measured**.
|
||||
This arises because if we measured three individual FRF such as \\(H\_{ik}(\omega)\\), \\(H\_{jk}(\omega)\\) and \\(K\_{kk}(\omega)\\), then modal analysis of these yields the modal parameters from which it is possible to generate the FRF \\(H\_{ij}(\omega)\\), \\(H\_{jj}(\omega)\\), etc.
|
||||
|
||||
However, it must be noted that there is an important **limitation to this procedure** which is highlighted in the example below.
|
||||
@@ -4661,7 +4659,7 @@ from which is would appear that we can write
|
||||
\end{aligned}
|
||||
\end{equation}
|
||||
|
||||
However, equation \ref{eq:m\_k\_from\_modes} is **only applicable when we have available the complete \\(N \times N\\) modal model**.
|
||||
However, equation \eqref{eq:m\_k\_from\_modes} is **only applicable when we have available the complete \\(N \times N\\) modal model**.
|
||||
|
||||
It is much more usual to have an incomplete model in which the eigenvector matrix is rectangle and, as such, is non-invertible.
|
||||
One step which can be made using the incomplete data is the construction of "pseudo" flexibility and inverse-mass matrices.
|
||||
|
||||
@@ -39,13 +39,13 @@ Typical value of \\(R\_s\\) is between \\(10\\) and \\(100 \Omega\\).
|
||||
When considering the effects of both output impedance and cable inductance, the transfer function from source voltage \\(V\_s\\) to load voltage \\(V\_L\\) is second-order low pass filter:
|
||||
|
||||
\begin{equation}
|
||||
\frac{V\_L(s)}{V\_s(s)} = \frac{1}{\frac{s^2}{\omega\_r^2} + 2 \xi \frac{s}{\omega\_r} + 1}
|
||||
\frac{V\_L(s)}{V\_s(s)} = \frac{1}{\frac{s^2}{\omega\_r^2} + 2 \zeta \frac{s}{\omega\_r} + 1}
|
||||
\end{equation}
|
||||
|
||||
with:
|
||||
|
||||
- \\(\omega\_r = \frac{1}{\sqrt{L C\_p}}\\)
|
||||
- \\(\xi = \frac{R\_s \sqrt{L C\_p}}{2 L}\\)
|
||||
- \\(\zeta = \frac{R\_s \sqrt{L C\_p}}{2 L}\\)
|
||||
|
||||
|
||||
## Amplifier small-signal Bandwidth {#amplifier-small-signal-bandwidth}
|
||||
|
||||
@@ -21,9 +21,7 @@ Year
|
||||
Matlab Code form the book is available [here](https://in.mathworks.com/matlabcentral/fileexchange/2186-vibration-simulation-using-matlab-and-ansys).
|
||||
|
||||
|
||||
## Introduction {#introduction}
|
||||
|
||||
<span class="org-target" id="org-target--sec-introduction"></span>
|
||||
## Introduction {#sec:introduction}
|
||||
|
||||
The main goal of this book is to show how to take results of large dynamic finite element models and build small Matlab state space dynamic mechanical models for use in control system models.
|
||||
|
||||
@@ -125,9 +123,8 @@ Because finite element models usually have a very large number of states, an imp
|
||||
| Principal Force Vector | \\(\bm{F}\_p\\) | \\(m \times 1\\) |
|
||||
|
||||
|
||||
## Zeros in SISO Mechanical Systems {#zeros-in-siso-mechanical-systems}
|
||||
## Zeros in SISO Mechanical Systems {#sec:zeros_siso_systems}
|
||||
|
||||
<span class="org-target" id="org-target--sec-zeros-siso-systems"></span>
|
||||
The origin and influence of poles are clear: they represent the resonant frequencies of the system, and for each resonance frequency, a mode shape can be defined to describe the motion at that frequency.
|
||||
|
||||
We here which to give an intuitive understanding for **when to expect zeros in SISO mechanical systems** and **how to predict the frequencies at which they will occur**.
|
||||
@@ -148,14 +145,10 @@ The resonances of the "overhanging appendages" of the constrained system create
|
||||
</div>
|
||||
|
||||
|
||||
## State Space Analysis {#state-space-analysis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-state-space-analysis"></span>
|
||||
## State Space Analysis {#sec:state_space_analysis}
|
||||
|
||||
|
||||
## Modal Analysis {#modal-analysis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-modal-analysis"></span>
|
||||
## Modal Analysis {#sec:modal_analysis}
|
||||
|
||||
Lightly damped structures are typically analyzed with the "normal mode" method described in this section.
|
||||
|
||||
@@ -252,7 +245,7 @@ where:
|
||||
|
||||
#### Eigenvalues / Characteristic Equation {#eigenvalues-characteristic-equation}
|
||||
|
||||
Re-injecting normal modes \ref{eq:principal\_mode} into the equation of motion \ref{eq:tdof\_eom} gives the eigenvalue problem:
|
||||
Re-injecting normal modes \eqref{eq:principal\_mode} into the equation of motion \eqref{eq:tdof\_eom} gives the eigenvalue problem:
|
||||
|
||||
\begin{equation}
|
||||
(\bm{k} - \omega\_i^2 \bm{m}) \bm{z}\_{mi} = 0
|
||||
@@ -310,7 +303,7 @@ Virtual interpretation of the eigenvectors are shown in [Figure 5](#figure--fig:
|
||||
|
||||
#### Modal Matrix {#modal-matrix}
|
||||
|
||||
The modal matrix is an \\(n \times m\\) matrix with columns corresponding to the \\(m\\) system eigenvectors as shown in Eq. \ref{eq:modal\_matrix}
|
||||
The modal matrix is an \\(n \times m\\) matrix with columns corresponding to the \\(m\\) system eigenvectors as shown in Eq. \eqref{eq:modal\_matrix}
|
||||
|
||||
\begin{equation}
|
||||
\bm{z}\_m = \begin{bmatrix}
|
||||
@@ -629,19 +622,19 @@ And the damping matrix expressed in the principal coordinates is:
|
||||
We note:
|
||||
|
||||
\begin{equation}
|
||||
c\_{pi} = a + b \omega\_i^2 = 2 \xi\_i \omega\_i
|
||||
c\_{pi} = a + b \omega\_i^2 = 2 \zeta\_i \omega\_i
|
||||
\end{equation}
|
||||
|
||||
where \\(\xi\_i\\) is the percentage of critical damping for the i'th mode:
|
||||
where \\(\zeta\_i\\) is the percentage of critical damping for the i'th mode:
|
||||
|
||||
\begin{equation}
|
||||
\xi\_i = \frac{c\_i}{2 \sqrt{k\_{pi} m\_{pi}}} = \frac{c\_i}{2 m\_{pi} \sqrt{\omega\_i^2}} = \frac{a + b \omega\_i^2}{2 \omega\_i}
|
||||
\zeta\_i = \frac{c\_i}{2 \sqrt{k\_{pi} m\_{pi}}} = \frac{c\_i}{2 m\_{pi} \sqrt{\omega\_i^2}} = \frac{a + b \omega\_i^2}{2 \omega\_i}
|
||||
\end{equation}
|
||||
|
||||
And the equation in principal coordinates becomes:
|
||||
|
||||
\begin{equation}
|
||||
\ddot{z}\_{pi} + 2 \xi\_i \omega\_i \dot{z}\_{pi} + \omega\_i^2 z\_{pi} = F\_{pi}
|
||||
\ddot{z}\_{pi} + 2 \zeta\_i \omega\_i \dot{z}\_{pi} + \omega\_i^2 z\_{pi} = F\_{pi}
|
||||
\end{equation}
|
||||
|
||||
This type of damping is known as **proportional damping**, where the damping for each mode is proportional to the critical damping for that mode.
|
||||
@@ -649,10 +642,10 @@ This type of damping is known as **proportional damping**, where the damping for
|
||||
|
||||
#### Simple Proportional Damping {#simple-proportional-damping}
|
||||
|
||||
Viscous damping in each mode is taken to be an arbitrary percentage \\(\xi\\) of the critical damping \\(c\_{cr}\\):
|
||||
Viscous damping in each mode is taken to be an arbitrary percentage \\(\zeta\\) of the critical damping \\(c\_{cr}\\):
|
||||
|
||||
\begin{equation}
|
||||
c = \frac{\xi}{2 \sqrt{k m}} = \xi \cdot c\_{cr}
|
||||
c = \frac{\zeta}{2 \sqrt{k m}} = \zeta \cdot c\_{cr}
|
||||
\end{equation}
|
||||
|
||||
|
||||
@@ -661,19 +654,19 @@ Viscous damping in each mode is taken to be an arbitrary percentage \\(\xi\\) of
|
||||
Recognizing that the higher modes of vibration damp out quickly, "relative" damping yields damping in proportion to frequencies in normal modes:
|
||||
|
||||
\begin{equation}
|
||||
\xi\_i = \frac{a + b\omega\_i^2}{2 \omega\_i}
|
||||
\zeta\_i = \frac{a + b\omega\_i^2}{2 \omega\_i}
|
||||
\end{equation}
|
||||
|
||||
If a value of \\(\xi\_1\\) for the first mode, is assumed:
|
||||
If a value of \\(\zeta\_1\\) for the first mode, is assumed:
|
||||
|
||||
\begin{equation}
|
||||
b = \frac{2 \xi\_1}{\omega\_1}
|
||||
b = \frac{2 \zeta\_1}{\omega\_1}
|
||||
\end{equation}
|
||||
|
||||
The value of the damping for any other mode is:
|
||||
|
||||
\begin{equation}
|
||||
\xi\_i = \xi\_1 \frac{\omega\_i}{\omega\_1}
|
||||
\zeta\_i = \zeta\_1 \frac{\omega\_i}{\omega\_1}
|
||||
\end{equation}
|
||||
|
||||
|
||||
@@ -685,9 +678,7 @@ Absolute damping is based on making \\(b = 0\\), in which case the percentage of
|
||||
## Modal Analysis: State Space Form {#modal-analysis-state-space-form}
|
||||
|
||||
|
||||
## Frequency Response: Modal Form {#frequency-response-modal-form}
|
||||
|
||||
<span class="org-target" id="org-target--sec-frequency-response-modal-form"></span>
|
||||
## Frequency Response: Modal Form {#sec:frequency_response_modal_form}
|
||||
|
||||
The procedure to obtain the frequency response from a modal form is as follow:
|
||||
|
||||
@@ -870,10 +861,10 @@ It can be shown that for a general system with \\(m\\) undamped modes:
|
||||
If modes have some damping:
|
||||
|
||||
\begin{equation}
|
||||
\frac{z\_j}{F\_k} = \sum\_{i = 1}^m \frac{z\_{nji} z\_{nki}}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2} \label{eq:general\_add\_tf\_damp}
|
||||
\frac{z\_j}{F\_k} = \sum\_{i = 1}^m \frac{z\_{nji} z\_{nki}}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2} \label{eq:general\_add\_tf\_damp}
|
||||
\end{equation}
|
||||
|
||||
Equations \ref{eq:general\_add\_tf} and \ref{eq:general\_add\_tf\_damp} shows that in general every transfer function is made up of **additive combinations of single degree of freedom systems**, with each system having its DC gain determined by the appropriate eigenvector entry product divided by the square of the eigenvalue, \\(z\_{nji} z\_{nki}/\omega\_i^2\\), and with resonant frequency defined by the eigenvalue \\(\omega\_i\\).
|
||||
Equations \eqref{eq:general\_add\_tf} and \eqref{eq:general\_add\_tf\_damp} shows that in general every transfer function is made up of **additive combinations of single degree of freedom systems**, with each system having its DC gain determined by the appropriate eigenvector entry product divided by the square of the eigenvalue, \\(z\_{nji} z\_{nki}/\omega\_i^2\\), and with resonant frequency defined by the eigenvalue \\(\omega\_i\\).
|
||||
|
||||
</div>
|
||||
|
||||
@@ -886,9 +877,7 @@ Equations \ref{eq:general\_add\_tf} and \ref{eq:general\_add\_tf\_damp} shows th
|
||||
The zeros for SISO transfer functions are the roots of the numerator, however, from modal analysis we can see that the zeros arise when modes combine with appropriate phase such that the resulting motion is null.
|
||||
|
||||
|
||||
## SISO State Space Matlab Model from ANSYS Model {#siso-state-space-matlab-model-from-ansys-model}
|
||||
|
||||
<span class="org-target" id="org-target--sec-siso-state-space"></span>
|
||||
## SISO State Space Matlab Model from ANSYS Model {#sec:siso_state_space}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -934,13 +923,13 @@ The DC gain contributions of the eliminated modes are not included in the overal
|
||||
In order to eliminate this error, the Matlab function `modred` is introduced.
|
||||
Using `modred` is analogous to using Guyan reduction to reduce some less important degrees of freedom.
|
||||
|
||||
We will discuss in this section two methods of sorting, one which is applicable for models with the same value of damping for all modes \\(\xi\_i = \xi\\) ("uniform" damping), and another which is applicable for models with different damping values for each mode ("non-uniform" damping).
|
||||
We will discuss in this section two methods of sorting, one which is applicable for models with the same value of damping for all modes \\(\zeta\_i = \zeta\\) ("uniform" damping), and another which is applicable for models with different damping values for each mode ("non-uniform" damping).
|
||||
|
||||
The general equation for the overall transfer function of undamped and damped systems are:
|
||||
|
||||
\begin{align}
|
||||
\frac{z\_j}{F\_k} &= \sum\_{i = 1}^m \frac{z\_{nji} z\_{nki}}{s^2 + \omega\_i^2} \\\\
|
||||
\frac{z\_j}{F\_k} &= \sum\_{i = 1}^m \frac{z\_{nji} z\_{nki}}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2}
|
||||
\frac{z\_j}{F\_k} &= \sum\_{i = 1}^m \frac{z\_{nji} z\_{nki}}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2}
|
||||
\end{align}
|
||||
|
||||
The **DC gain** of the i'th mode can be obtained by substituting \\(s = j\omega = 0\\):
|
||||
@@ -954,12 +943,12 @@ where \\(z\_{nji} z\_{nki}\\) is the product of the j'th (output) row and k'th (
|
||||
At resonance, the **peak gain** amplitude of each mode is given by substituting \\(s = j \omega\_i\\):
|
||||
|
||||
\begin{equation}
|
||||
\text{Peak gain}\_i = \frac{z\_{ji}}{F\_{ki}} = \frac{-j}{2 \xi\_i} \frac{z\_{nji} z\_{nki}}{\omega\_i^2}
|
||||
\text{Peak gain}\_i = \frac{z\_{ji}}{F\_{ki}} = \frac{-j}{2 \zeta\_i} \frac{z\_{nji} z\_{nki}}{\omega\_i^2}
|
||||
\end{equation}
|
||||
|
||||
And we see that the peak gain for a mode is the DC gain of the same mode divided by \\(2 \xi\_i\\).
|
||||
And we see that the peak gain for a mode is the DC gain of the same mode divided by \\(2 \zeta\_i\\).
|
||||
|
||||
If the same value of \\(\xi\\) is used for all modes, then all the DC gain terms are divided by the same \\(2 \xi\\) terms and the relative amplitude of the DC gains and peak gains are the same, so there is no difference between sorting a uniform damping model using DC gain or peak gain.
|
||||
If the same value of \\(\zeta\\) is used for all modes, then all the DC gain terms are divided by the same \\(2 \zeta\\) terms and the relative amplitude of the DC gains and peak gains are the same, so there is no difference between sorting a uniform damping model using DC gain or peak gain.
|
||||
|
||||
However, if the modes have different damping the relationship between the DC gain and peak gain for all the modes is not a constant value and peak gain must be used to rank modes for importance.
|
||||
|
||||
@@ -974,9 +963,7 @@ However, the `truncate` method has the advantage that it does not exhibit the un
|
||||
If sorting of DC gain values is performed prior to the `truncate` operation, the system DC gain error may be acceptable while maintaining better high frequency performance.
|
||||
|
||||
|
||||
## Ground Acceleration Matlab Model From ANSYS Model {#ground-acceleration-matlab-model-from-ansys-model}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ground-acceleration"></span>
|
||||
## Ground Acceleration Matlab Model From ANSYS Model {#sec:ground_acceleration}
|
||||
|
||||
|
||||
### Model Description {#model-description}
|
||||
@@ -988,9 +975,7 @@ If sorting of DC gain values is performed prior to the `truncate` operation, the
|
||||
### Matlab State Space Model from Eigenvalue Run {#matlab-state-space-model-from-eigenvalue-run}
|
||||
|
||||
|
||||
## SISO Disk Drive Actuator Model {#siso-disk-drive-actuator-model}
|
||||
|
||||
<span class="org-target" id="org-target--sec-siso-disk-drive"></span>
|
||||
## SISO Disk Drive Actuator Model {#sec:siso_disk_drive}
|
||||
|
||||
In this section we wish to extract a SISO state space model from a Finite Element model representing a Disk Drive Actuator ([Figure 12](#figure--fig:hatch00-disk-drive-siso-model)).
|
||||
|
||||
@@ -1072,9 +1057,7 @@ The dimensions of this operation are \\((1 \times n) \times (n \times m) = (1 \t
|
||||
From Ansys, we have the eigenvalues \\(\omega\_i\\) and eigenvectors \\(\bm{z}\\).
|
||||
|
||||
|
||||
## Balanced Reduction {#balanced-reduction}
|
||||
|
||||
<span class="org-target" id="org-target--sec-balanced-reduction"></span>
|
||||
## Balanced Reduction {#sec:balanced_reduction}
|
||||
|
||||
In this chapter another method of reducing models, “balanced reduction”, will be introduced and compared with the DC and peak gain ranking methods.
|
||||
|
||||
@@ -1187,9 +1170,7 @@ Because the controllability and observability gramians are identical, there is n
|
||||
The **states to be kept are the states with the largest diagonal terms**.
|
||||
|
||||
|
||||
## MIMO Two Stage Actuator Model {#mimo-two-stage-actuator-model}
|
||||
|
||||
<span class="org-target" id="org-target--sec-mimo-disk-drive"></span>
|
||||
## MIMO Two Stage Actuator Model {#sec:mimo_disk_drive}
|
||||
|
||||
In this section, a MIMO two-stage actuator model is derived from a finite element model ([Figure 14](#figure--fig:hatch00-disk-drive-mimo-schematic)).
|
||||
|
||||
|
||||
@@ -1099,84 +1099,6 @@ Experiment shows that the magnitude of the force depends directly on the current
|
||||
|
||||
### A2.9. Equivalent Circuit Under Variable-Frequency Conditions {#a2-dot-9-dot-equivalent-circuit-under-variable-frequency-conditions}
|
||||
|
||||
|
||||
## Further Reading {#further-reading}
|
||||
|
||||
|
||||
## Index {#index}
|
||||
|
||||
|
||||
### A {#a}
|
||||
|
||||
|
||||
### B {#b}
|
||||
|
||||
|
||||
### C {#c}
|
||||
|
||||
|
||||
### D {#d}
|
||||
|
||||
|
||||
### E {#e}
|
||||
|
||||
|
||||
### F {#f}
|
||||
|
||||
|
||||
### G {#g}
|
||||
|
||||
|
||||
### H {#h}
|
||||
|
||||
|
||||
### I {#i}
|
||||
|
||||
|
||||
### J {#j}
|
||||
|
||||
|
||||
### K {#k}
|
||||
|
||||
|
||||
### L {#l}
|
||||
|
||||
|
||||
### M {#m}
|
||||
|
||||
|
||||
### N {#n}
|
||||
|
||||
|
||||
### O {#o}
|
||||
|
||||
|
||||
### P {#p}
|
||||
|
||||
|
||||
### Q {#q}
|
||||
|
||||
|
||||
### R {#r}
|
||||
|
||||
|
||||
### S {#s}
|
||||
|
||||
|
||||
### T {#t}
|
||||
|
||||
|
||||
### U {#u}
|
||||
|
||||
|
||||
### V {#v}
|
||||
|
||||
|
||||
### W {#w}
|
||||
|
||||
|
||||
## Color Plates {#color-plates}
|
||||
|
||||
<style>.csl-entry{text-indent: -1.5em; margin-left: 1.5em;}</style><div class="csl-bib-body">
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_1"></a>Hughes, Austin, and Bill Drury. 2013. <i>Electric Motors and Drives: Fundamentals, Types and Applications</i>. Newnes.</div>
|
||||
</div>
|
||||
@@ -125,7 +125,7 @@ And we see that \\(H\\) has units of amperes per meter.
|
||||
The magnetic field of a solenoid is shown in [Figure 7](#figure--fig:morrison16-solenoid).
|
||||
The field intensity inside the solenoid is nearly constant, while outside its intensity falls of rapidly.
|
||||
|
||||
Using Ampere's law \ref{eq:ampere\_law:}
|
||||
Using Ampere's law \eqref{eq:ampere\_law:}
|
||||
|
||||
\begin{equation}
|
||||
\oint H dl \approx n I l
|
||||
@@ -187,12 +187,12 @@ V = n^2 A k \mu\_0 \frac{dI}{dt} = L \frac{dI}{dt}
|
||||
|
||||
where \\(k\\) relates to the geometry of the coil.
|
||||
|
||||
Equation \ref{eq:inductance\_coil} states that if \\(V\\) is one volt, then for an inductance of one henry, the current will rise at the rate of one ampere per second.
|
||||
Equation \eqref{eq:inductance\_coil} states that if \\(V\\) is one volt, then for an inductance of one henry, the current will rise at the rate of one ampere per second.
|
||||
|
||||
|
||||
### The energy stored in an inductance {#the-energy-stored-in-an-inductance}
|
||||
|
||||
One way to calculate the work stored in a magnetic field is to use Eq. \ref{eq:inductance\_coil}.
|
||||
One way to calculate the work stored in a magnetic field is to use Eq. \eqref{eq:inductance\_coil}.
|
||||
The voltage \\(V\\) applied to a coil results in a linearly increasing current.
|
||||
At any time \\(t\\), the power \\(P\\) supplied is equal to \\(VI\\).
|
||||
Power is the rate of change of energy or \\(P = d\bm{E}/dt\\) where \\(\bm{E}\\) is the stored energy in the inductance.
|
||||
|
||||
@@ -345,27 +345,27 @@ If we left multiply the equation by \\(\Phi^T\\) and we use the orthogonalily re
|
||||
\\[ diag(\mu\_i) \ddot{z} + \Phi^T C \Phi + diag(\mu\_i \omega\_i^2) z = \Phi^T f \\]
|
||||
|
||||
If \\(\Phi^T C \Phi\\) is diagonal, the **damping is said classical or normal**. In this case:
|
||||
\\[ \Phi^T C \Phi = diag(2 \xi\_i \mu\_i \omega\_i) \\]
|
||||
\\[ \Phi^T C \Phi = diag(2 \zeta\_i \mu\_i \omega\_i) \\]
|
||||
|
||||
One can verify that the Rayleigh damping \ref{eq:rayleigh\_damping} complies with this condition with modal damping ratios \\(\xi\_i = \frac{1}{2} ( \frac{\alpha}{\omega\_i} + \beta\omega\_i )\\).
|
||||
One can verify that the Rayleigh damping \eqref{eq:rayleigh\_damping} complies with this condition with modal damping ratios \\(\zeta\_i = \frac{1}{2} ( \frac{\alpha}{\omega\_i} + \beta\omega\_i )\\).
|
||||
|
||||
And we obtain decoupled modal equations \ref{eq:modal\_eom}.
|
||||
And we obtain decoupled modal equations \eqref{eq:modal\_eom}.
|
||||
|
||||
<div class="cbox">
|
||||
|
||||
\begin{equation}\label{eq:modal\_eom}
|
||||
\ddot{z} + 2 \xi \Omega \dot{z} + \Omega^2 z = z^{-1} \Phi^T f
|
||||
\ddot{z} + 2 \zeta \Omega \dot{z} + \Omega^2 z = z^{-1} \Phi^T f
|
||||
\end{equation}
|
||||
|
||||
with:
|
||||
|
||||
- \\(\xi = diag(\xi\_i)\\)
|
||||
- \\(\zeta = diag(\zeta\_i)\\)
|
||||
- \\(\Omega = diag(\omega\_i)\\)
|
||||
- \\(\mu = diag(\mu\_i)\\)
|
||||
|
||||
</div>
|
||||
|
||||
Typical values of the modal damping ratio are summarized on table [Table 2](#table--tab:damping-ratio).
|
||||
Typical values of the modal damping ratio are summarized on [Table 2](#table--tab:damping-ratio).
|
||||
|
||||
<a id="table--tab:damping-ratio"></a>
|
||||
<div class="table-caption">
|
||||
@@ -373,24 +373,24 @@ Typical values of the modal damping ratio are summarized on table [Table 2](#tab
|
||||
Typical Damping ratio
|
||||
</div>
|
||||
|
||||
| **Damping Ratio** | **Application** |
|
||||
|--------------------------------|-------------------------|
|
||||
| \\(\xi \simeq 0.001 - 0.005\\) | Space structures |
|
||||
| \\(\xi \simeq 0.01 - 0.02\\) | Mechanical engineering |
|
||||
| \\(\xi \simeq 0.05\\) | Civil engineering |
|
||||
| \\(\xi \simeq 0.2\\) | When ground is involved |
|
||||
| **Damping Ratio** | **Application** |
|
||||
|----------------------------------|-------------------------|
|
||||
| \\(\zeta \simeq 0.001 - 0.005\\) | Space structures |
|
||||
| \\(\zeta \simeq 0.01 - 0.02\\) | Mechanical engineering |
|
||||
| \\(\zeta \simeq 0.05\\) | Civil engineering |
|
||||
| \\(\zeta \simeq 0.2\\) | When ground is involved |
|
||||
|
||||
The assumption of classical damping is often justified for light damping, but it is questionable when the damping is large.
|
||||
|
||||
If one accepts the assumption of classical damping, the only difference between equation \ref{eq:general\_eom} and \ref{eq:modal\_eom} lies in the change of coordinates.
|
||||
If one accepts the assumption of classical damping, the only difference between equation \eqref{eq:general\_eom} and \eqref{eq:modal\_eom} lies in the change of coordinates.
|
||||
However, in physical coordinates, the number of degrees of freedom is usually very large.
|
||||
If a structure is excited in by a band limited excitation, its response is dominated by the modes whose natural frequencies are inside the bandwidth of the excitation and the equation \ref{eq:modal\_eom} can often be restricted to theses modes.
|
||||
If a structure is excited in by a band limited excitation, its response is dominated by the modes whose natural frequencies are inside the bandwidth of the excitation and the equation \eqref{eq:modal\_eom} can often be restricted to theses modes.
|
||||
Therefore, the number of degrees of freedom contribution effectively to the response is **reduced drastically** in modal coordinates.
|
||||
|
||||
|
||||
#### Dynamic Flexibility Matrix {#dynamic-flexibility-matrix}
|
||||
|
||||
If we consider the steady-state response of equation \ref{eq:general\_eom} to harmonic excitation \\(f=F e^{j\omega t}\\), the response is also harmonic \\(x = Xe^{j\omega t}\\). The amplitude of \\(F\\) and \\(X\\) is related by:
|
||||
If we consider the steady-state response of equation \eqref{eq:general\_eom} to harmonic excitation \\(f=F e^{j\omega t}\\), the response is also harmonic \\(x = Xe^{j\omega t}\\). The amplitude of \\(F\\) and \\(X\\) is related by:
|
||||
\\[ X = G(\omega) F \\]
|
||||
|
||||
Where \\(G(\omega)\\) is called the **Dynamic flexibility Matrix**:
|
||||
@@ -407,7 +407,7 @@ With:
|
||||
- \\(D\_i(\omega)\\) is the dynamic amplification factor of mode \\(i\\) given by
|
||||
|
||||
\begin{equation}\label{eq:dynamic\_amplification}
|
||||
D\_i(\omega) = \frac{1}{1 - \omega^2/\omega\_i^2 + 2 j \xi\_i \omega/\omega\_i}
|
||||
D\_i(\omega) = \frac{1}{1 - \omega^2/\omega\_i^2 + 2 j \zeta\_i \omega/\omega\_i}
|
||||
\end{equation}
|
||||
|
||||
<a id="figure--fig:neglected-modes"></a>
|
||||
@@ -489,7 +489,7 @@ By looking at [Figure 7](#figure--fig:collocated-control-frf), we see that negle
|
||||
The open-loop transfer function of a lighly damped structure with a collocated actuator/sensor pair can be written:
|
||||
|
||||
\begin{equation}\label{eq:frf\_lighly\_damped\_collocated}
|
||||
G(s) = G\_0 \frac{\Pi\_i(s^2/z\_i^2 + 2 \xi\_i s/z\_i + 1)}{\Pi\_j(s^2/\omega\_j^2 + 2 \xi\_j s /\omega\_j + 1)}
|
||||
G(s) = G\_0 \frac{\Pi\_i(s^2/z\_i^2 + 2 \zeta\_i s/z\_i + 1)}{\Pi\_j(s^2/\omega\_j^2 + 2 \zeta\_j s /\omega\_j + 1)}
|
||||
\end{equation}
|
||||
|
||||
The corresponding Bode plot is represented in [Figure 9](#figure--fig:alternating-p-z). Every imaginary pole at \\(\pm j\omega\_i\\) introduces a \\(\SI{180}{\degree}\\) phase lag and every imaginary zero at \\(\pm jz\_i\\) introduces a phase lead of \\(\SI{180}{\degree}\\).
|
||||
@@ -576,14 +576,14 @@ The transfer function between the total force and the current \\(i\\) applied to
|
||||
<div class="cbox">
|
||||
|
||||
\begin{equation}\label{eq:proof\_mass\_eq}
|
||||
\frac{F}{i} = \frac{-s^2 T}{s^2 + 2\xi\_p \omega\_p s + \omega\_p^2}
|
||||
\frac{F}{i} = \frac{-s^2 T}{s^2 + 2\zeta\_p \omega\_p s + \omega\_p^2}
|
||||
\end{equation}
|
||||
|
||||
with:
|
||||
|
||||
- \\(T\\) is the transducer constant
|
||||
- \\(\omega\_p = \frac{k}{m}\\) is the natural frequency of the spring-mass system
|
||||
- \\(\xi\_p\\) is the damping ratio
|
||||
- \\(\zeta\_p\\) is the damping ratio
|
||||
|
||||
</div>
|
||||
|
||||
@@ -609,7 +609,7 @@ If \\(x\_0\\) is the displacement of the support and if the voice coil is open (
|
||||
By using the two equations, we obtain:
|
||||
|
||||
\begin{equation}\label{eq:geophone}
|
||||
\frac{e}{\dot{x\_0}} = \frac{-s^2 T}{s^2 + 2\xi\_p\omega\_p s + \omega\_p^2}
|
||||
\frac{e}{\dot{x\_0}} = \frac{-s^2 T}{s^2 + 2\zeta\_p\omega\_p s + \omega\_p^2}
|
||||
\end{equation}
|
||||
|
||||
Above the corner frequency, the gain of the geophone is equal to the transducer constant \\(T\\).
|
||||
@@ -647,7 +647,7 @@ With:
|
||||
- \\(T\_{me}\\) is the transduction coefficient representing the force acting on the mechanical terminals to balance the electromagnetic force induced per unit current input (in \\(N/A\\))
|
||||
- \\(Z\_m\\) is the mechanical impedance measured when \\(i=0\\)
|
||||
|
||||
Equation \ref{eq:gen\_trans\_e} shows that the voltage across the electrical terminals of any electromechanical transducer is the sum of a contribution proportional to the current applied and a contribution proportional to the velocity of the mechanical terminals.
|
||||
Equation \eqref{eq:gen\_trans\_e} shows that the voltage across the electrical terminals of any electromechanical transducer is the sum of a contribution proportional to the current applied and a contribution proportional to the velocity of the mechanical terminals.
|
||||
Thus, if \\(Z\_ei\\) can be measured and substracted from \\(e\\), a signal proportional to the velocity is obtained.
|
||||
|
||||
To do so, the bridge circuit as shown on [Figure 15](#figure--fig:bridge-circuit) can be used.
|
||||
@@ -719,7 +719,7 @@ With:
|
||||
|
||||
#### Constitutive Relations of a Discrete Transducer {#constitutive-relations-of-a-discrete-transducer}
|
||||
|
||||
The set of equations \ref{eq:piezo\_eq} can be written in a matrix form:
|
||||
The set of equations \eqref{eq:piezo\_eq} can be written in a matrix form:
|
||||
|
||||
\begin{equation}\label{eq:piezo\_eq\_matrix}
|
||||
\begin{bmatrix}
|
||||
@@ -769,7 +769,7 @@ It measures the efficiency of the conversion of the mechanical energy into elect
|
||||
|
||||
</div>
|
||||
|
||||
If one assumes that all the electrical and mechanical quantities are uniformly distributed in a linear transducer formed by a **stack** (see [Figure 17](#figure--fig:piezo-stack)) of \\(n\\) disks of thickness \\(t\\) and cross section \\(A\\), the global constitutive equations of the transducer are obtained by integrating \ref{eq:piezo\_eq\_matrix\_bis} over the volume of the transducer:
|
||||
If one assumes that all the electrical and mechanical quantities are uniformly distributed in a linear transducer formed by a **stack** (see [Figure 17](#figure--fig:piezo-stack)) of \\(n\\) disks of thickness \\(t\\) and cross section \\(A\\), the global constitutive equations of the transducer are obtained by integrating \eqref{eq:piezo\_eq\_matrix\_bis} over the volume of the transducer:
|
||||
|
||||
\begin{equation}\label{eq:piezo\_stack\_eq}
|
||||
\begin{bmatrix}
|
||||
@@ -798,7 +798,7 @@ where
|
||||
|
||||
{{< figure src="/ox-hugo/preumont18_piezo_stack.png" caption="<span class='figure-number'>Figure 17: </span>Piezoelectric linear transducer" >}}
|
||||
|
||||
Equation \ref{eq:piezo\_stack\_eq} can be inverted to obtain
|
||||
Equation \eqref{eq:piezo\_stack\_eq} can be inverted to obtain
|
||||
|
||||
\begin{equation}\label{eq:piezo\_stack\_eq\_inv}
|
||||
\begin{bmatrix}
|
||||
@@ -830,7 +830,7 @@ The total power delivered to the transducer is the sum of electric power \\(V i\
|
||||
|
||||
{{< figure src="/ox-hugo/preumont18_piezo_discrete.png" caption="<span class='figure-number'>Figure 18: </span>Discrete Piezoelectric Transducer" >}}
|
||||
|
||||
By integrating equation \ref{eq:piezo\_work} and using the constitutive equations \ref{eq:piezo\_stack\_eq\_inv}, we obtain the analytical expression of the stored electromechanical energy for the discrete transducer:
|
||||
By integrating equation \eqref{eq:piezo\_work} and using the constitutive equations \eqref{eq:piezo\_stack\_eq\_inv}, we obtain the analytical expression of the stored electromechanical energy for the discrete transducer:
|
||||
|
||||
\begin{equation}\label{eq:piezo\_stack\_work}
|
||||
W\_e(\Delta, Q) = \frac{Q^2}{2 C (1 - k^2)} - \frac{n d\_{33} K\_a}{C(1-k^2)} Q\Delta + \frac{K\_a}{1-k^2}\frac{\Delta^2}{2}
|
||||
@@ -882,7 +882,7 @@ And one can see that
|
||||
\frac{z^2 - p^2}{z^2} = k^2
|
||||
\end{equation}
|
||||
|
||||
Equation \ref{eq:distance\_p\_z} constitutes a practical way to determine the electromechanical coupling factor from the poles and zeros of the admittance measurement ([Figure 20](#figure--fig:piezo-admittance-curve)).
|
||||
Equation \eqref{eq:distance\_p\_z} constitutes a practical way to determine the electromechanical coupling factor from the poles and zeros of the admittance measurement ([Figure 20](#figure--fig:piezo-admittance-curve)).
|
||||
|
||||
<a id="figure--fig:piezo-admittance-curve"></a>
|
||||
|
||||
|
||||
@@ -428,7 +428,7 @@ In this chapter some important lessons have been learned, which are summarised a
|
||||
- Stiffness, whether it is created mechanically or by means of a control system, is determinative for precision
|
||||
- Every mechanical structure can be modelled as a combination of bodies, springs and dampers, either as separate bodies or as finite elements within a body
|
||||
- Phase is prominent factor regarding the possibility to control the motion of a mechanical system
|
||||
- The quality factor \\(Q\\) and damping ratio \\(\xi\\) are inverse proportional. Each have their practical value.
|
||||
- The quality factor \\(Q\\) and damping ratio \\(\zeta\\) are inverse proportional. Each have their practical value.
|
||||
- A damping placed in parallel with a lumped mass-spring system limits the magnitude of the resonance at the natural frequency.
|
||||
However, it also increases the transmissibility at frequencies above the native frequency.
|
||||
- The dynamic behavior of a complex system and its response to a stimulus can be derived and understood by viewing it as a superposition of contributions of its eigenmodes, each with its own mode-shape, eigenfrequency, modal parameters and damping.
|
||||
@@ -454,7 +454,7 @@ The core of the control system is the _plant_, which is the physical system that
|
||||
<a id="table--tab:walk-control-loop"></a>
|
||||
<div class="table-caption">
|
||||
<span class="table-number"><a href="#table--tab:walk-control-loop">Table 3</a>:</span>
|
||||
Symbols used in <a href="#orgda28b83">3</a>
|
||||
Symbols used in <a href="#org9f480e2">3</a>
|
||||
</div>
|
||||
|
||||
| Symbol | Meaning | Unit |
|
||||
@@ -633,7 +633,7 @@ The measured frequency-response of the scanning unit taken as as an example is s
|
||||
A mathematical model of a seconder-order mass-spring system with a force input is fitted to this measured response:
|
||||
|
||||
\begin{equation}
|
||||
G(s) = \frac{C\_f \omega\_0^2}{s^2 + 2\xi\_f \omega\_0 s + \omega\_0^2}
|
||||
G(s) = \frac{C\_f \omega\_0^2}{s^2 + 2\zeta\_f \omega\_0 s + \omega\_0^2}
|
||||
\end{equation}
|
||||
|
||||
When positioning at high scanning frequency, the resonance at the first mode-shape of this scanning unit causes oscillations, which adversely affect the tracking accuracy.
|
||||
@@ -641,7 +641,7 @@ In order to solve this problem, a feedforward controller is designed that compen
|
||||
This means that the transfer function of the feedforward controller is:
|
||||
|
||||
\begin{equation}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \xi\_f \omega\_0 s + \omega\_0^2}{\omega\_0^2}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \zeta\_f \omega\_0 s + \omega\_0^2}{\omega\_0^2}
|
||||
\end{equation}
|
||||
|
||||
However, such controller needs to be modified in such a way that it becomes _realizable_.
|
||||
@@ -649,23 +649,23 @@ In this case, it is decided to create a resulting overall transfer function of t
|
||||
In order to realize this controller, first two poles have to be added:
|
||||
|
||||
\begin{equation}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \xi\_f \omega\_0 s + \omega\_0^2}{s^2 + 2\cdot 1 \cdot \omega\_0 s + \omega\_0^2}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \zeta\_f \omega\_0 s + \omega\_0^2}{s^2 + 2\cdot 1 \cdot \omega\_0 s + \omega\_0^2}
|
||||
\end{equation}
|
||||
|
||||
There the damping ratio of the resulting dynamics is chosen to be \\(\xi = 1\\).
|
||||
There the damping ratio of the resulting dynamics is chosen to be \\(\zeta = 1\\).
|
||||
|
||||
This feedforward controller is basically a _notch filter_.
|
||||
In order to create an additional attenuation of higher frequency resonances due to flexible-body mode-shapes, another first-order pole is added at the first eigenfrequency:
|
||||
|
||||
\begin{equation}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \xi\_f \omega\_0 s + \omega\_0^2}{(s + \omega\_0)(s^2 + 2\omega\_0 s + \omega\_0^2)}
|
||||
C\_{ff}(s) = \frac{s^2 + 2 \zeta\_f \omega\_0 s + \omega\_0^2}{(s + \omega\_0)(s^2 + 2\omega\_0 s + \omega\_0^2)}
|
||||
\end{equation}
|
||||
|
||||
Then this controller is connected in series with the scanning unit, the anti-resonance of the controller and the resonance of the piezo-scanner cancel each other out:
|
||||
|
||||
\begin{align}
|
||||
G\_{t,ff}(s) &= G(s)G\_{ff}(s) \\\\
|
||||
&= \frac{C\_f}{s^2 + 2 \xi\_f \omega\_0 s + \omega\_0^2} \frac{s^2 + 2 \xi\_f \omega\_0 s + \omega\_0^2}{(s + \omega\_0){s^2 + 2 \omega\_0 s + \omega\_0^2}} \\\\
|
||||
&= \frac{C\_f}{s^2 + 2 \zeta\_f \omega\_0 s + \omega\_0^2} \frac{s^2 + 2 \zeta\_f \omega\_0 s + \omega\_0^2}{(s + \omega\_0){s^2 + 2 \omega\_0 s + \omega\_0^2}} \\\\
|
||||
&= \frac{C\_f}{(s + \omega\_0){s^2 + 2 \omega\_0 s + \omega\_0^2}}
|
||||
\end{align}
|
||||
|
||||
@@ -753,7 +753,7 @@ There are derived from a simplified version of the generic feedback loop as show
|
||||
The first simplification is made by approximating the measurement system to have a unity-gain transfer function.
|
||||
For further simplification the sensor disturbance in the measurement system is included in the output disturbance \\(n\\), thereby defining the output of the system \\(y\\) as the measured output.
|
||||
With this simplified model, the transfer functions of the different inputs of the system to three relevant output variables in the loop are written down in a set of equations.
|
||||
Six different transfer functions are obtained and summarized in equation \ref{eq:gang\_of\_six}.
|
||||
Six different transfer functions are obtained and summarized in equation \eqref{eq:gang\_of\_six}.
|
||||
|
||||
\begin{equation} \label{eq:gang\_of\_six}
|
||||
\begin{aligned}
|
||||
@@ -766,7 +766,7 @@ Six different transfer functions are obtained and summarized in equation \ref{eq
|
||||
\end{aligned}
|
||||
\end{equation}
|
||||
|
||||
In case no input filter is applied \\(F\\) is equal to one and the set of six equations is reduced to a set of four equations as shown in equation \ref{eq:gang\_of\_four}.
|
||||
In case no input filter is applied \\(F\\) is equal to one and the set of six equations is reduced to a set of four equations as shown in equation \eqref{eq:gang\_of\_four}.
|
||||
This short set of equations also corresponds to the situation without a reference signal.
|
||||
|
||||
The most important transfer function is named the _Sensitivity Function_ (no unit):
|
||||
|
||||
@@ -63,9 +63,7 @@ PDF version
|
||||
</div>
|
||||
|
||||
|
||||
## Introduction {#introduction}
|
||||
|
||||
<span class="org-target" id="org-target--sec-introduction"></span>
|
||||
## Introduction {#sec:introduction}
|
||||
|
||||
|
||||
### The Process of Control System Design {#the-process-of-control-system-design}
|
||||
@@ -87,10 +85,10 @@ The process of designing a control system is a step by step design procedure as
|
||||
13. Choose hardware and software and implement the controller
|
||||
14. Test and validate the control system, and tune the controller on-line, if necessary
|
||||
|
||||
Input-output controllability analysis is studied in section for SISO systems and in section for MIMO systems.
|
||||
The steps 4, 5, 6 and 7 are corresponding to the **control structure design**. This is treated in section .
|
||||
The design of the controller is described in section .
|
||||
The analysis of performance and robustness of a controlled system is studied in sections and .
|
||||
Input-output controllability analysis is studied in section [Limitations on Performance in SISO Systems](#sec:perf_limit_siso) for SISO systems and in section [Limitations on Performance in MIMO Systems](#sec:perf_limit_mimo) for MIMO systems.
|
||||
The steps 4, 5, 6 and 7 are corresponding to the **control structure design**. This is treated in section [Controller Structure Design](#sec:controller_structure_design).
|
||||
The design of the controller is described in section [Controller Design](#sec:controller_design).
|
||||
The analysis of performance and robustness of a controlled system is studied in sections [Uncertainty and Robustness for SISO Systems](#sec:uncertainty_robustness_siso) and [Robust Stability and Performance Analysis](#sec:robust_perf_mimo).
|
||||
|
||||
|
||||
### The Control Problem {#the-control-problem}
|
||||
@@ -238,9 +236,7 @@ Notations used throughout this note are summarized in [Table 1](#table--tab:nota
|
||||
| \\(T\\) | Complementary sensitivity function: \\(T = (I + L)\*(I + L)^{-1}\\) |
|
||||
|
||||
|
||||
## Classical Feedback Control {#classical-feedback-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-classical-feedback"></span>
|
||||
## Classical Feedback Control {#sec:classical_feedback}
|
||||
|
||||
|
||||
### Frequency Response {#frequency-response}
|
||||
@@ -721,9 +717,7 @@ To combined these **mixed sensitivity specifications**, a **stacking approach**
|
||||
After selecting the form of \\(N\\) and the weights, the \\(\hinf\\) optimal controller is obtained by solving the problem \\(\min\_K\hnorm{N(K)}\\).
|
||||
|
||||
|
||||
## Introduction to Multivariable Control {#introduction-to-multivariable-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-multivariable-control"></span>
|
||||
## Introduction to Multivariable Control {#sec:multivariable_control}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -1235,9 +1229,7 @@ MIMO systems are often **more sensitive to uncertainty** than SISO systems.
|
||||
</div>
|
||||
|
||||
|
||||
## Elements of Linear System Theory {#elements-of-linear-system-theory}
|
||||
|
||||
<span class="org-target" id="org-target--sec-linear-sys-theory"></span>
|
||||
## Elements of Linear System Theory {#sec:linear_sys_theory}
|
||||
|
||||
|
||||
### System Descriptions {#system-descriptions}
|
||||
@@ -1768,9 +1760,7 @@ The Hankel norm is a kind of induced norm from past inputs to future outputs.
|
||||
It may be shown that the Hankel norm is equal to \\(\left\\|G(s)\right\\|\_H = \sqrt{\rho(PQ)}\\) where \\(\rho\\) is the spectral radius, \\(P\\) is the controllability Gramian and \\(Q\\) the observability Gramian.
|
||||
|
||||
|
||||
## Limitations on Performance in SISO Systems {#limitations-on-performance-in-siso-systems}
|
||||
|
||||
<span class="org-target" id="org-target--sec-perf-limit-siso"></span>
|
||||
## Limitations on Performance in SISO Systems {#sec:perf_limit_siso}
|
||||
|
||||
|
||||
### Input-Output Controllability {#input-output-controllability}
|
||||
@@ -2292,9 +2282,7 @@ They are not sufficient since among other things they only consider one effect a
|
||||
The rules may be used to **determine whether or not a given plant is controllable**.
|
||||
|
||||
|
||||
## Limitations on Performance in MIMO Systems {#limitations-on-performance-in-mimo-systems}
|
||||
|
||||
<span class="org-target" id="org-target--sec-perf-limit-mimo"></span>
|
||||
## Limitations on Performance in MIMO Systems {#sec:perf_limit_mimo}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -2808,9 +2796,7 @@ For RHP-zeros, RHP-poles and disturbances, the issue of directions usually makes
|
||||
However, the situation is usually the opposite with model uncertainty because for MIMO systems, there is also uncertainty associated with plant directionality.
|
||||
|
||||
|
||||
## Uncertainty and Robustness for SISO Systems {#uncertainty-and-robustness-for-siso-systems}
|
||||
|
||||
<span class="org-target" id="org-target--sec-uncertainty-robustness-siso"></span>
|
||||
## Uncertainty and Robustness for SISO Systems {#sec:uncertainty_robustness_siso}
|
||||
|
||||
|
||||
### Introduction to Robustness {#introduction-to-robustness}
|
||||
@@ -3551,9 +3537,7 @@ Similarly, the inverse multiplicative uncertainty imposes an upper bound on the
|
||||
We also derived a condition for robust performance with multiplicative uncertainty, \\(\abs{w\_P S} + \abs{w\_I T} < 1, \ \forall\w\\).
|
||||
|
||||
|
||||
## Robust Stability and Performance Analysis {#robust-stability-and-performance-analysis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-robust-perf-mimo"></span>
|
||||
## Robust Stability and Performance Analysis {#sec:robust_perf_mimo}
|
||||
|
||||
|
||||
### General Control Configuration with Uncertainty {#general-control-configuration-with-uncertainty}
|
||||
@@ -4474,7 +4458,7 @@ The peak value is close to 6, meaning that even with 6 times less uncertainty, t
|
||||
|
||||
We here consider the relationship between \\(\mu\\) for RP and the condition number of the plant or of the controller.
|
||||
We consider unstructured multiplicative uncertainty (i.e. \\(\Delta\_I\\) is a full matrix) and performance is measured in terms of the weighted sensitivity.
|
||||
With \\(N\\) given by \ref{eq:n\_delta\_structure\_clasic}, we have:
|
||||
With \\(N\\) given by \eqref{eq:n\_delta\_structure\_clasic}, we have:
|
||||
|
||||
\begin{equation\*}
|
||||
\overbrace{\mu\_{\tilde{\Delta}}(N)}^{\text{RP}} \le [ \overbrace{\overline{\sigma}(w\_I T\_I)}^{\text{RS}} + \overbrace{\overline{\sigma}(w\_P S)}^{\text{NP}} ] (1 + \sqrt{k})
|
||||
@@ -4711,9 +4695,7 @@ If resulting control performance is not satisfactory, one may switch to the seco
|
||||
4. \\(\mu\\) is most commonly used for analysis. If \\(\mu\\) is used for synthesis, then we recommend that you keep the uncertainty fixed and adjust the parameters in the performance weight until \\(\mu\\) is close to 1
|
||||
|
||||
|
||||
## Controller Design {#controller-design}
|
||||
|
||||
<span class="org-target" id="org-target--sec-controller-design"></span>
|
||||
## Controller Design {#sec:controller_design}
|
||||
|
||||
|
||||
### Trade-offs in MIMO Feedback Design {#trade-offs-in-mimo-feedback-design}
|
||||
@@ -4921,14 +4903,11 @@ These procedure are somehow difficult to use in practice.
|
||||
Their main limitation is that they can only be applied to minimum phase plants.
|
||||
|
||||
|
||||
### \\(\htwo\\) and \\(\hinf\\) Control {#htwo-and-hinf-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-htwo-and-hinf"></span>
|
||||
### \\(\htwo\\) and \\(\hinf\\) Control {#sec:htwo_and_hinf}
|
||||
|
||||
|
||||
#### General Control Problem Formulation {#general-control-problem-formulation}
|
||||
#### General Control Problem Formulation {#sec:htwo_inf_assumptions}
|
||||
|
||||
<span class="org-target" id="org-target--sec-htwo-inf-assumptions"></span>
|
||||
There are many ways in which feedback design problems can be cast as \\(\htwo\\) and \\(\hinf\\) optimization problems.
|
||||
It is very useful therefore to have a **standard problem formulation** into which any particular problem may be manipulated.
|
||||
|
||||
@@ -5466,13 +5445,12 @@ for a specified \\(\gamma > \gamma\_\text{min}\\), is given by
|
||||
L &= (1-\gamma^2) I + XZ
|
||||
\end{align}
|
||||
|
||||
The Matlab function `coprimeunc` can be used to generate the controller in \ref{eq:control\_coprime\_factor}.
|
||||
It is important to emphasize that since we can compute \\(\gamma\_\text{min}\\) from \ref{eq:gamma\_min\_coprime} we get an explicit solution by solving just two Riccati equations and avoid the \\(\gamma\text{-iteration}\\) needed to solve the general \\(\mathcal{H}\_\infty\\) problem.
|
||||
The Matlab function `coprimeunc` can be used to generate the controller in \eqref{eq:control\_coprime\_factor}.
|
||||
It is important to emphasize that since we can compute \\(\gamma\_\text{min}\\) from \eqref{eq:gamma\_min\_coprime} we get an explicit solution by solving just two Riccati equations and avoid the \\(\gamma\text{-iteration}\\) needed to solve the general \\(\mathcal{H}\_\infty\\) problem.
|
||||
|
||||
|
||||
#### A Systematic \\(\hinf\\) Loop-Shaping Design Procedure {#a-systematic-hinf-loop-shaping-design-procedure}
|
||||
#### A Systematic \\(\hinf\\) Loop-Shaping Design Procedure {#sec:hinf_loop_shaping_procedure}
|
||||
|
||||
<span class="org-target" id="org-target--sec-hinf-loop-shaping-procedure"></span>
|
||||
Robust stabilization alone is not much used in practice because the designer is not able to specify any performance requirements.
|
||||
|
||||
To do so, **pre and post compensators** are used to **shape the open-loop singular values** prior to robust stabilization of the "shaped" plant.
|
||||
@@ -5552,7 +5530,7 @@ The commands and feedbacks enter the controller separately and are independently
|
||||
|
||||
{{< figure src="/ox-hugo/skogestad07_classical_feedback_2dof_simple.png" caption="<span class='figure-number'>Figure 55: </span>General two degrees-of-freedom feedback control scheme" >}}
|
||||
|
||||
The presented \\(\mathcal{H}\_\infty\\) loop-shaping design procedure in section is a one-degree-of-freedom design, although a **constant** pre-filter can be easily implemented for steady-state accuracy.
|
||||
The presented \\(\mathcal{H}\_\infty\\) loop-shaping design procedure in section [A Systematic \\(\hinf\\) Loop-Shaping Design Procedure](#sec:hinf_loop_shaping_procedure) is a one-degree-of-freedom design, although a **constant** pre-filter can be easily implemented for steady-state accuracy.
|
||||
However, this may not be sufficient and a dynamic two degrees-of-freedom design is required.<br />
|
||||
|
||||
The design problem is illustrated in [Figure 56](#figure--fig:coprime-uncertainty-hinf).
|
||||
@@ -5586,7 +5564,7 @@ The purpose of the prefilter is to ensure that:
|
||||
|
||||
The main steps required to synthesize a two degrees-of-freedom \\(\mathcal{H}\_\infty\\) loop-shaping controller are:
|
||||
|
||||
1. Design a one degree-of-freedom \\(\mathcal{H}\_\infty\\) loop-shaping controller (section ) but without a post-compensator \\(W\_2\\)
|
||||
1. Design a one degree-of-freedom \\(\mathcal{H}\_\infty\\) loop-shaping controller (section [A Systematic \\(\hinf\\) Loop-Shaping Design Procedure](#sec:hinf_loop_shaping_procedure)) but without a post-compensator \\(W\_2\\)
|
||||
2. Select a desired closed-loop transfer function \\(T\_{\text{ref}}\\) between the commands and controller outputs
|
||||
3. Set the scalar parameter \\(\rho\\) to a small value greater than \\(1\\); something in the range \\(1\\) to \\(3\\) will usually suffice
|
||||
4. For the shaped \\(G\_s = G W\_1\\), the desired response \\(T\_{\text{ref}}\\), and the scalar parameter \\(\rho\\), solve the standard \\(\mathcal{H}\_\infty\\) optimization problem to a specified tolerance to get \\(K = [K\_1,\ K\_2]\\)
|
||||
@@ -5733,9 +5711,7 @@ Sometimes, one might consider synthesizing a \\(\mu\text{-optimal}\\) controller
|
||||
Moreover, one should be careful about combining controller synthesis and analysis into a single step.
|
||||
|
||||
|
||||
## Controller Structure Design {#controller-structure-design}
|
||||
|
||||
<span class="org-target" id="org-target--sec-controller-structure-design"></span>
|
||||
## Controller Structure Design {#sec:controller_structure_design}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -6214,7 +6190,7 @@ Four applications of partial control are:
|
||||
The outputs \\(y\_1\\) have an associated control objective but are not measured.
|
||||
Instead, we aim at indirectly controlling \\(y\_1\\) by controlling the secondary measured variables \\(y\_2\\).
|
||||
|
||||
The table [Table 4](#table--tab:partial-control) shows clearly the differences between the four applications of partial control.
|
||||
The [Table 4](#table--tab:partial-control) shows clearly the differences between the four applications of partial control.
|
||||
In all cases, there is a control objective associated with \\(y\_1\\) and a feedback involving measurement and control of \\(y\_2\\) and we want:
|
||||
|
||||
- The effect of disturbances on \\(y\_1\\) to be small (when \\(y\_2\\) is controlled)
|
||||
@@ -6314,7 +6290,7 @@ The selection of \\(u\_2\\) and \\(y\_2\\) for use in the lower-layer control sy
|
||||
Consider the conventional cascade control system in [Figure 62a](#org-target--fig-cascade-extra-meas) where we have additional "secondary" measurements \\(y\_2\\) with no associated control objective, and the objective is to improve the control of \\(y\_1\\) by locally controlling \\(y\_2\\).
|
||||
The idea is that this should reduce the effect of disturbances and uncertainty on \\(y\_1\\).
|
||||
|
||||
From \ref{eq:partial\_control}, it follows that we should select \\(y\_2\\) and \\(u\_2\\) such that \\(\\|P\_d\\|\\) is small and at least smaller than \\(\\|G\_{d1}\\|\\).
|
||||
From \eqref{eq:partial\_control}, it follows that we should select \\(y\_2\\) and \\(u\_2\\) such that \\(\\|P\_d\\|\\) is small and at least smaller than \\(\\|G\_{d1}\\|\\).
|
||||
These arguments particularly apply at high frequencies.
|
||||
More precisely, we want the input-output controllability of \\([P\_u\ P\_r]\\) with disturbance model \\(P\_d\\) to be better that of the plant \\([G\_{11}\ G\_{12}]\\) with disturbance model \\(G\_{d1}\\).
|
||||
|
||||
@@ -6330,7 +6306,7 @@ A set of outputs \\(y\_1\\) may be left uncontrolled only if the effects of all
|
||||
|
||||
</div>
|
||||
|
||||
To evaluate the feasibility of partial control, one must for each choice of \\(y\_2\\) and \\(u\_2\\), rearrange the system as in \ref{eq:partial\_control\_partitioning} and \ref{eq:partial\_control}, and compute \\(P\_d\\) using \ref{eq:tight\_control\_y2}.
|
||||
To evaluate the feasibility of partial control, one must for each choice of \\(y\_2\\) and \\(u\_2\\), rearrange the system as in \eqref{eq:partial\_control\_partitioning} and \eqref{eq:partial\_control}, and compute \\(P\_d\\) using \eqref{eq:tight\_control\_y2}.
|
||||
|
||||
|
||||
#### Measurement Selection for Indirect Control {#measurement-selection-for-indirect-control}
|
||||
@@ -6500,7 +6476,7 @@ We then derive **necessary conditions for stability** which may be used to elimi
|
||||
|
||||
For decentralized diagonal control, it is desirable that the system can be tuned and operated one loop at a time.
|
||||
Assume therefore that \\(G\\) is stable and each individual loop is stable by itself (\\(\tilde{S}\\) and \\(\tilde{T}\\) are stable).
|
||||
Using the **spectral radius condition** on the factorized \\(S\\) in \ref{eq:S\_factorization}, we have that the overall system is stable (\\(S\\) is stable) if
|
||||
Using the **spectral radius condition** on the factorized \\(S\\) in \eqref{eq:S\_factorization}, we have that the overall system is stable (\\(S\\) is stable) if
|
||||
|
||||
\begin{equation}
|
||||
\rho(E\tilde{T}(j\omega)) < 1, \forall\omega
|
||||
@@ -6725,7 +6701,7 @@ When a reasonable choice of pairings have been made, one should rearrange \\(G\\
|
||||
|1 + L\_i| > \max\_{k,j}\\{|\tilde{g}\_{dik}|, |\gamma\_{ij}|\\}
|
||||
\end{equation}
|
||||
|
||||
To achieve stability of the individual loops, one must analyze \\(g\_{ii}(s)\\) to ensure that the bandwidth required by \ref{eq:decent\_contr\_one\_loop} is achievable.
|
||||
To achieve stability of the individual loops, one must analyze \\(g\_{ii}(s)\\) to ensure that the bandwidth required by \eqref{eq:decent\_contr\_one\_loop} is achievable.
|
||||
Note that RHP-zeros in the diagonal elements may limit achievable decentralized control, whereas they may not pose any problems for a multivariable controller.
|
||||
Since with decentralized control, we usually want to use simple controllers, the achievable bandwidth in each loop will be limited by the frequency where \\(\angle g\_{ii}\\) is \\(\SI{-180}{\degree}\\)
|
||||
6. Check for constraints by considering the elements of \\(G^{-1} G\_d\\) and make sure that they do not exceed one in magnitude within the frequency range where control is needed.
|
||||
@@ -6741,7 +6717,7 @@ When a reasonable choice of pairings have been made, one should rearrange \\(G\\
|
||||
If the plant is not controllable, then one may consider another choice of pairing and go back to Step 4.
|
||||
If one still cannot find any pairing which are controllable, then one should consider multivariable control.
|
||||
|
||||
7. If the chosen pairing is controllable, then \ref{eq:decent\_contr\_one\_loop} tells us how large \\(|L\_i| = |g\_{ii} k\_i|\\) must be.
|
||||
7. If the chosen pairing is controllable, then \eqref{eq:decent\_contr\_one\_loop} tells us how large \\(|L\_i| = |g\_{ii} k\_i|\\) must be.
|
||||
This can be used as a basis for designing the controller \\(k\_i(s)\\) for loop \\(i\\)
|
||||
|
||||
|
||||
@@ -6761,16 +6737,14 @@ Thus sequential design may involve many iterations.
|
||||
|
||||
#### Conclusion on Decentralized Control {#conclusion-on-decentralized-control}
|
||||
|
||||
A number of **conditions for the stability**, e.g. \ref{eq:decent\_contr\_cond\_stability} and \ref{eq:decent\_contr\_necessary\_cond\_stability}, and **performance**, e.g. \ref{eq:decent\_contr\_cond\_perf\_dist} and \ref{eq:decent\_contr\_cond\_perf\_ref}, of decentralized control systems have been derived.
|
||||
A number of **conditions for the stability**, e.g. \eqref{eq:decent\_contr\_cond\_stability} and \eqref{eq:decent\_contr\_necessary\_cond\_stability}, and **performance**, e.g. \eqref{eq:decent\_contr\_cond\_perf\_dist} and \eqref{eq:decent\_contr\_cond\_perf\_ref}, of decentralized control systems have been derived.
|
||||
|
||||
The conditions may be useful in **determining appropriate pairings of inputs and outputs** and the **sequence in which the decentralized controllers should be designed**.
|
||||
|
||||
The conditions are also useful in an **input-output controllability analysis** for determining the viability of decentralized control.
|
||||
|
||||
|
||||
## Model Reduction {#model-reduction}
|
||||
|
||||
<span class="org-target" id="org-target--sec-model-reduction"></span>
|
||||
## Model Reduction {#sec:model_reduction}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -7193,3 +7167,8 @@ In such a case, using truncation or optimal Hankel norm approximation with appro
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
<style>.csl-entry{text-indent: -1.5em; margin-left: 1.5em;}</style><div class="csl-bib-body">
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_1"></a>Doyle, John C. 1983. “Synthesis of Robust Controllers and Filters.” In <i>The 22nd IEEE Conference on Decision and Control</i>, 109–14. IEEE.</div>
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_2"></a>Skogestad, S., and I. Postlethwaite. 2007. <i>Multivariable Feedback Control: Analysis and Design - Second Edition</i>. John Wiley.</div>
|
||||
</div>
|
||||
@@ -22,34 +22,30 @@ PDF version
|
||||
: [link](/ox-hugo/taghirad13_paral.pdf)
|
||||
|
||||
|
||||
## Introduction {#introduction}
|
||||
|
||||
<span class="org-target" id="org-target--sec-introduction"></span>
|
||||
## Introduction {#sec:introduction}
|
||||
|
||||
This book is intended to give some analysis and design tools for the increase number of engineers and researchers who are interested in the design and implementation of parallel robots.
|
||||
A systematic approach is presented to analyze the kinematics, dynamics and control of parallel robots.
|
||||
To define the motion characteristics of such robots, it is necessary to represent 3D motion of the robot moving platform with respect to a fixed coordinate.
|
||||
This issue leads to the requirements for 3D representation of position, orientation and motion of bodies in space.
|
||||
In chapter , such representation are introduced with emphasis on screw coordinates, which makes the representation of the general motion of the robot much easier to follow.<br />
|
||||
In chapter [Motion Representation](#sec:motion_representation), such representation are introduced with emphasis on screw coordinates, which makes the representation of the general motion of the robot much easier to follow.<br />
|
||||
|
||||
Kinematic analysis refers to the study of robot motion geometry without considering the forces and torques that cause the motion.
|
||||
In this analysis (chapter ), the relation between the geometrical parameters of the manipulator and the final motion of the moving platform is derived and analyzed.<br />
|
||||
In this analysis (chapter [Kinematics](#sec:kinematics)), the relation between the geometrical parameters of the manipulator and the final motion of the moving platform is derived and analyzed.<br />
|
||||
|
||||
In Chapter , the kinematics analysis of robot manipulators is further examined beyond static positioning.
|
||||
In Chapter [Jacobian: Velocities and Static Forces](#sec:jacobian), the kinematics analysis of robot manipulators is further examined beyond static positioning.
|
||||
Jacobian analysis not only reveals the relation between the joint variable velocities of a parallel manipulator and the moving platform linear and angular velocities, but also constructs the transformation needed to find the actuator forces from the forces and moments acting on the moving platform.
|
||||
A systematic means to perform Jacobian analysis of parallel manipulators is given in this chapter.<br />
|
||||
|
||||
Dynamic analysis of parallel manipulators presents an inherent complexity due to their closed-loop structure and kinematic constraints.
|
||||
Nevertheless, dynamic modeling is quite important for the control, in particular because parallel manipulators are preferred in applications where precise positioning and suitable dynamic performance under high loads are the prime requirements.
|
||||
In Chapter , the dynamic analysis of such robots is examined through three methods, namely the Newton-Euler principle of virtual work and Lagrange formations.
|
||||
In Chapter [Dynamics](#sec:dynamics), the dynamic analysis of such robots is examined through three methods, namely the Newton-Euler principle of virtual work and Lagrange formations.
|
||||
Furthermore, a method is presented in this chapter to formulate the dynamic equation of parallel robots into closed form, by which the dynamic matrices are more tractable, and dynamics verification becomes feasible.<br />
|
||||
|
||||
The control of parallel robots is elaborated in the last two chapters, in which both the motion and force control are covered.
|
||||
|
||||
|
||||
## Motion Representation {#motion-representation}
|
||||
|
||||
<span class="org-target" id="org-target--sec-motion-representation"></span>
|
||||
## Motion Representation {#sec:motion_representation}
|
||||
|
||||
|
||||
### Spatial Motion Representation {#spatial-motion-representation}
|
||||
@@ -264,7 +260,7 @@ If the pose of a rigid body \\(\\{{}^A\bm{R}\_B, {}^A\bm{P}\_{O\_B}\\}\\) is giv
|
||||
|
||||
### Homogeneous Transformations {#homogeneous-transformations}
|
||||
|
||||
To describe general transformations, we introduce the \\(4\times1\\) **homogeneous coordinates**, and Eq. \ref{eq:chasles\_therorem} is generalized to
|
||||
To describe general transformations, we introduce the \\(4\times1\\) **homogeneous coordinates**, and Eq. \eqref{eq:chasles\_therorem} is generalized to
|
||||
|
||||
\begin{equation} \label{eq:homogeneous\_transformation}
|
||||
\boxed{{}^A\bm{P} = {}^A\bm{T}\_B {}^B\bm{P}}
|
||||
@@ -427,9 +423,7 @@ Hence, the **inverse of the transformation matrix** can be obtain by
|
||||
\end{equation}
|
||||
|
||||
|
||||
## Kinematics {#kinematics}
|
||||
|
||||
<span class="org-target" id="org-target--sec-kinematics"></span>
|
||||
## Kinematics {#sec:kinematics}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -581,9 +575,7 @@ The forward kinematic problem is then to solve many **highly nonlinear equations
|
||||
The complexity of the problem depends widely on the manipulator architecture and geometry.
|
||||
|
||||
|
||||
## Jacobian: Velocities and Static Forces {#jacobian-velocities-and-static-forces}
|
||||
|
||||
<span class="org-target" id="org-target--sec-jacobian"></span>
|
||||
## Jacobian: Velocities and Static Forces {#sec:jacobian}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -620,7 +612,7 @@ The direction of \\(\bm{\Omega}\\) indicates the instantaneous axis of rotation
|
||||
|
||||
</div>
|
||||
|
||||
The angular velocity vector is related to the screw formalism by equation \ref{eq:angular\_velocity\_vector}.
|
||||
The angular velocity vector is related to the screw formalism by equation \eqref{eq:angular\_velocity\_vector}.
|
||||
|
||||
\begin{equation} \label{eq:angular\_velocity\_vector}
|
||||
\boxed{\bm{\Omega} \triangleq \dot{\theta} \hat{\bm{s}}}
|
||||
@@ -695,7 +687,7 @@ The time derivative of the rotation matrix \\({}^A\dot{\bm{R}}\_B\\) is:
|
||||
\boxed{{}^A\dot{\bm{R}}\_B = {}^A\bm{\Omega}^\times \ {}^A\bm{R}\_B}
|
||||
\end{equation}
|
||||
|
||||
And we finally obtain equation \ref{eq:absolute\_velocity\_formula}.
|
||||
And we finally obtain equation \eqref{eq:absolute\_velocity\_formula}.
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -755,7 +747,7 @@ The **general Jacobian matrix** is defined as:
|
||||
\dot{\bm{q}} = \bm{J} \dot{\bm{\mathcal{X}}}
|
||||
\end{equation}
|
||||
|
||||
From equation \ref{eq:jacobians}, we have:
|
||||
From equation \eqref{eq:jacobians}, we have:
|
||||
|
||||
\begin{equation}
|
||||
\bm{J} = {\bm{J}\_q}^{-1} \bm{J}\_x
|
||||
@@ -842,7 +834,7 @@ Moreover, we have:
|
||||
- \\({}^A\dot{\bm{R}}\_B {}^B\bm{b}\_i = {}^A\bm{\omega} \times {}^A\bm{R}\_B {}^B\bm{b}\_i = {}^A\bm{\omega} \times {}^A\bm{b}\_i\\) in which \\({}^A\bm{\omega}\\) denotes the angular velocity of the moving platform expressed in the fixed frame \\(\\{\bm{A}\\}\\).
|
||||
- \\(l\_i {}^A\dot{\hat{\bm{s}}}\_i = l\_i \left( {}^A\bm{\omega}\_i \times \hat{\bm{s}}\_i \right)\\) in which \\({}^A\bm{\omega}\_i\\) is the angular velocity of limb \\(i\\) express in fixed frame \\(\\{\bm{A}\\}\\).
|
||||
|
||||
Then, the velocity loop closure \ref{eq:loop\_closure\_limb\_diff} simplifies to
|
||||
Then, the velocity loop closure \eqref{eq:loop\_closure\_limb\_diff} simplifies to
|
||||
\\[ {}^A\bm{v}\_p + {}^A\bm{\omega} \times {}^A\bm{b}\_i = \dot{l}\_i {}^A\hat{\bm{s}}\_i + l\_i ({}^A\bm{\omega}\_i \times \hat{\bm{s}}\_i) \\]
|
||||
|
||||
By dot multiply both side of the equation by \\(\hat{\bm{s}}\_i\\):
|
||||
@@ -880,9 +872,9 @@ We then omit the superscript \\(A\\) and we can rearrange the 6 equations into a
|
||||
#### Singularity Analysis {#singularity-analysis}
|
||||
|
||||
It is of primary importance to avoid singularities in a given workspace.
|
||||
To study the singularity configurations of the Stewart-Gough platform, we consider the Jacobian matrix determined with the equation \ref{eq:jacobian\_formula\_stewart}.<br />
|
||||
To study the singularity configurations of the Stewart-Gough platform, we consider the Jacobian matrix determined with the equation \eqref{eq:jacobian\_formula\_stewart}.<br />
|
||||
|
||||
From equation \ref{eq:jacobians}, it is clear that for the Stewart-Gough platform, \\(\bm{J}\_q = \bm{I}\\) and \\(\bm{J}\_x = \bm{J}\\).
|
||||
From equation \eqref{eq:jacobians}, it is clear that for the Stewart-Gough platform, \\(\bm{J}\_q = \bm{I}\\) and \\(\bm{J}\_x = \bm{J}\\).
|
||||
Hence the manipulator has **no inverse kinematic singularities** within the manipulator workspace, but **may possess forward kinematic singularity** when \\(\bm{J}\\) becomes rank deficient. This may occur when
|
||||
\\[ \det \bm{J} = 0 \\]
|
||||
|
||||
@@ -1001,7 +993,7 @@ The relation between the applied actuator force \\(\tau\_i\\) and the correspond
|
||||
|
||||
in which \\(k\_i\\) denotes the **stiffness constant of the actuator**.<br />
|
||||
|
||||
Re-writing the equation \ref{eq:stiffness\_actuator} for all limbs in a matrix form result in
|
||||
Re-writing the equation \eqref{eq:stiffness\_actuator} for all limbs in a matrix form result in
|
||||
|
||||
\begin{equation} \label{eq:stiffness\_matrix\_relation}
|
||||
\boxed{\bm{\tau} = \mathcal{K} \cdot \Delta \bm{q}}
|
||||
@@ -1010,7 +1002,7 @@ Re-writing the equation \ref{eq:stiffness\_actuator} for all limbs in a matrix f
|
||||
in which \\(\bm{\tau}\\) is the vector of actuator forces, and \\(\Delta \bm{q}\\) corresponds to the actuator deflections.
|
||||
\\(\mathcal{K} = \text{diag}\left[ k\_1 \ k\_2 \dots k\_m \right]\\) is an \\(m \times m\\) diagonal matrix composed of the actuator stiffness constants.<br />
|
||||
|
||||
Writing the Jacobian relation given in equation \ref{eq:jacobian\_disp} for infinitesimal deflection read
|
||||
Writing the Jacobian relation given in equation \eqref{eq:jacobian\_disp} for infinitesimal deflection read
|
||||
|
||||
\begin{equation} \label{eq:jacobian\_disp\_inf}
|
||||
\Delta \bm{q} = \bm{J} \cdot \Delta \bm{\mathcal{X}}
|
||||
@@ -1018,19 +1010,19 @@ Writing the Jacobian relation given in equation \ref{eq:jacobian\_disp} for infi
|
||||
|
||||
in which \\(\Delta \bm{\mathcal{X}} = [\Delta x\ \Delta y\ \Delta z\ \Delta\theta x\ \Delta\theta y\ \Delta\theta z]\\) is the infinitesimal linear and angular deflection of the moving platform.
|
||||
|
||||
Furthermore, rewriting the Jacobian as the projection of actuator forces to the moving platform \ref{eq:jacobian\_forces} gives
|
||||
Furthermore, rewriting the Jacobian as the projection of actuator forces to the moving platform \eqref{eq:jacobian\_forces} gives
|
||||
|
||||
\begin{equation} \label{eq:jacobian\_force\_inf}
|
||||
\bm{\mathcal{F}} = \bm{J}^T \bm{\tau}
|
||||
\end{equation}
|
||||
|
||||
Hence, by substituting \ref{eq:stiffness\_matrix\_relation} and \ref{eq:jacobian\_disp\_inf} in \ref{eq:jacobian\_force\_inf}, we obtain:
|
||||
Hence, by substituting \eqref{eq:stiffness\_matrix\_relation} and \eqref{eq:jacobian\_disp\_inf} in \eqref{eq:jacobian\_force\_inf}, we obtain:
|
||||
|
||||
\begin{equation} \label{eq:stiffness\_jacobian}
|
||||
\boxed{\bm{\mathcal{F}} = \underbrace{\bm{J}^T \mathcal{K} \bm{J}}\_{\bm{K}} \cdot \Delta \bm{\mathcal{X}}}
|
||||
\end{equation}
|
||||
|
||||
Equation \ref{eq:stiffness\_jacobian} implies that the moving platform output wrench is related to its deflection by the **stiffness matrix** \\(K\\).
|
||||
Equation \eqref{eq:stiffness\_jacobian} implies that the moving platform output wrench is related to its deflection by the **stiffness matrix** \\(K\\).
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1123,9 +1115,7 @@ The maximum stiffness of the manipulator can be analyzed by the maximum singular
|
||||
The largest axis of the stiffness transformation hyper-ellipsoid is given by this value at each configuration.
|
||||
|
||||
|
||||
## Dynamics {#dynamics}
|
||||
|
||||
<span class="org-target" id="org-target--sec-dynamics"></span>
|
||||
## Dynamics {#sec:dynamics}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -1208,7 +1198,7 @@ where \\(\\{\theta, \hat{\bm{s}}\\}\\) are the screw parameters representing the
|
||||
|
||||
</div>
|
||||
|
||||
As shown by \ref{eq:angular\_acceleration}, the angular acceleration of the rigid body is also along the screw axis \\(\hat{\bm{s}}\\) with a magnitude equal to \\(\ddot{\theta}\\).
|
||||
As shown by \eqref{eq:angular\_acceleration}, the angular acceleration of the rigid body is also along the screw axis \\(\hat{\bm{s}}\\) with a magnitude equal to \\(\ddot{\theta}\\).
|
||||
|
||||
|
||||
##### Linear Acceleration of a Point {#linear-acceleration-of-a-point}
|
||||
@@ -1305,7 +1295,7 @@ in which
|
||||
|
||||
##### Principal Axes {#principal-axes}
|
||||
|
||||
As seen in equation \ref{eq:moment\_inertia}, the inertia matrix elements are a function of mass distribution of the rigid body with respect to the frame \\(\\{\bm{A}\\}\\).
|
||||
As seen in equation \eqref{eq:moment\_inertia}, the inertia matrix elements are a function of mass distribution of the rigid body with respect to the frame \\(\\{\bm{A}\\}\\).
|
||||
Hence, it is possible to find **orientations of frame** \\(\\{\bm{A}\\}\\) in which the product of inertia terms vanish and inertia matrix becomes **diagonal**:
|
||||
|
||||
\begin{equation} \label{eq:inertia\_matrix\_diagonal}
|
||||
@@ -1393,10 +1383,10 @@ Therefore, angular momentum of the rigid body about point \\(A\\) is reduced to
|
||||
in which
|
||||
\\[ {}^C\bm{H} = \int\_V \bm{r} \times (\bm{\Omega} \times \bm{r}) \rho dV = {}^C\bm{I} \cdot \bm{\Omega} \\]
|
||||
|
||||
Equation \ref{eq:angular\_momentum} reveals that angular momentum of a rigid body about a point \\(A\\) can be written as \\(\bm{p}\_c \times \bm{G}\_c\\), which is the contribution of linear momentum of the rigid body about point \\(A\\), and \\({}^C\bm{H}\\) which is the angular momentum of the rigid body about the center of mass.
|
||||
Equation \eqref{eq:angular\_momentum} reveals that angular momentum of a rigid body about a point \\(A\\) can be written as \\(\bm{p}\_c \times \bm{G}\_c\\), which is the contribution of linear momentum of the rigid body about point \\(A\\), and \\({}^C\bm{H}\\) which is the angular momentum of the rigid body about the center of mass.
|
||||
|
||||
This also highlights the important of the center of mass in the dynamic analysis of rigid bodies.
|
||||
If the center of mass is taken as the reference point, the relation describing angular momentum \ref{eq:angular\_momentum} is very analogous to that of linear momentum \ref{eq:linear\_momentum}.
|
||||
If the center of mass is taken as the reference point, the relation describing angular momentum \eqref{eq:angular\_momentum} is very analogous to that of linear momentum \eqref{eq:linear\_momentum}.
|
||||
|
||||
|
||||
##### Kinetic Energy {#kinetic-energy}
|
||||
@@ -1608,7 +1598,7 @@ in which \\(\bm{\mathcal{X}} = [\bm{x}\_P, \bm{\theta}]^T\\) is the motion varia
|
||||
|
||||
#### Closed-Form Dynamics {#closed-form-dynamics}
|
||||
|
||||
While dynamic formulation in the form of Equation \ref{eq:dynamic\_formulation\_implicit} can be used to simulate inverse dynamics of the Stewart-Gough platform, its implicit nature makes it unpleasant for the dynamic analysis and control.
|
||||
While dynamic formulation in the form of Equation \eqref{eq:dynamic\_formulation\_implicit} can be used to simulate inverse dynamics of the Stewart-Gough platform, its implicit nature makes it unpleasant for the dynamic analysis and control.
|
||||
|
||||
|
||||
##### Closed-Form Dynamics of the Limbs {#closed-form-dynamics-of-the-limbs}
|
||||
@@ -1666,7 +1656,7 @@ It is preferable to use the **screw coordinates** for representing the angular m
|
||||
\ddot{\bm{\mathcal{X}}} = \begin{bmatrix}\bm{a}\_p \\\ \dot{\bm{\omega}}\end{bmatrix}}
|
||||
\end{equation}
|
||||
|
||||
Equations \ref{eq:dyn\_form\_implicit\_trans} and \ref{eq:dyn\_form\_implicit\_rot} can be simply converted into a closed form of Equation \ref{eq:close\_form\_dynamics\_platform} with the following terms:
|
||||
Equations \eqref{eq:dyn\_form\_implicit\_trans} and \eqref{eq:dyn\_form\_implicit\_rot} can be simply converted into a closed form of Equation \eqref{eq:close\_form\_dynamics\_platform} with the following terms:
|
||||
|
||||
\begin{equation} \label{eq:close\_form\_dynamics\_stewart\_terms}
|
||||
\begin{aligned}
|
||||
@@ -1729,7 +1719,7 @@ As shown in [Figure 13](#figure--fig:stewart-forward-dynamics), it is **assumed
|
||||
|
||||
{{< figure src="/ox-hugo/taghirad13_stewart_forward_dynamics.png" caption="<span class='figure-number'>Figure 13: </span>Flowchart of forward dynamics implementation sequence" >}}
|
||||
|
||||
The closed-form dynamic formulation of the Stewart-Gough platform corresponds to the set of equations given in \ref{eq:closed\_form\_dynamic\_stewart\_wanted}, whose terms are given in \ref{eq:close\_form\_dynamics\_stewart\_terms}.
|
||||
The closed-form dynamic formulation of the Stewart-Gough platform corresponds to the set of equations given in \eqref{eq:closed\_form\_dynamic\_stewart\_wanted}, whose terms are given in \eqref{eq:close\_form\_dynamics\_stewart\_terms}.
|
||||
|
||||
|
||||
##### Inverse Dynamics Simulation {#inverse-dynamics-simulation}
|
||||
@@ -1744,11 +1734,11 @@ For such a trajectory, \\(\bm{\mathcal{X}}\_{d}(t)\\) and the time derivatives \
|
||||
The next step is to solve the inverse kinematics of the manipulator and to find the limbs' linear and angular positions, velocity and acceleration as a function of the manipulator trajectory.
|
||||
The manipulator Jacobian matrix \\(\bm{J}\\) is also calculated in this step.
|
||||
|
||||
Next, the dynamic matrices given in the closed-form formulations of the limbs and the moving platform are calculated using equations \ref{eq:closed\_form\_intermediate\_parameters} and \ref{eq:close\_form\_dynamics\_stewart\_terms}, respectively.<br />
|
||||
Next, the dynamic matrices given in the closed-form formulations of the limbs and the moving platform are calculated using equations \eqref{eq:closed\_form\_intermediate\_parameters} and \eqref{eq:close\_form\_dynamics\_stewart\_terms}, respectively.<br />
|
||||
|
||||
To combine the corresponding matrices, an to generate the whole manipulator dynamics, it is necessary to find intermediate Jacobian matrices \\(\bm{J}\_i\\), given in \ref{eq:jacobian\_intermediate}, and then compute compatible matrices for the limbs given in \ref{eq:closed\_form\_stewart\_manipulator}.
|
||||
To combine the corresponding matrices, an to generate the whole manipulator dynamics, it is necessary to find intermediate Jacobian matrices \\(\bm{J}\_i\\), given in \eqref{eq:jacobian\_intermediate}, and then compute compatible matrices for the limbs given in \eqref{eq:closed\_form\_stewart\_manipulator}.
|
||||
Now that all the terms required to **computed to actuator forces required to generate such a trajectory** is computed, let us define \\(\bm{\mathcal{F}}\\) as the resulting Cartesian wrench applied to the moving platform.
|
||||
This wrench can be calculated from the summation of all inertial and external forces **excluding the actuator torques** \\(\bm{\tau}\\) in the closed-form dynamic formulation \ref{eq:closed\_form\_dynamic\_stewart\_wanted}.
|
||||
This wrench can be calculated from the summation of all inertial and external forces **excluding the actuator torques** \\(\bm{\tau}\\) in the closed-form dynamic formulation \eqref{eq:closed\_form\_dynamic\_stewart\_wanted}.
|
||||
|
||||
By this definition, \\(\bm{\mathcal{F}}\\) can be viewed as the projector of the actuator forces acting on the manipulator, mapped to the Cartesian space.
|
||||
Since there is no redundancy in actuation in the Stewart-Gough manipulator, the Jacobian matrix \\(\bm{J}\\), squared and actuator forces can be uniquely determined from this wrench, by \\(\bm{\tau} = \bm{J}^{-T} \bm{\mathcal{F}}\\), provided \\(\bm{J}\\) is non-singular.
|
||||
@@ -1781,9 +1771,7 @@ Therefore, actuator forces \\(\bm{\tau}\\) are computed in the simulation from
|
||||
\end{equation}
|
||||
|
||||
|
||||
## Motion Control {#motion-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-motion-control"></span>
|
||||
## Motion Control {#sec:motion_control}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
@@ -1802,9 +1790,7 @@ One of the reasons why such decentralization can perform well in practice is the
|
||||
However, using advanced techniques in nonlinear and MIMO control permits to overcome limitations of the SISO approach.
|
||||
|
||||
|
||||
### Controller Topology {#controller-topology}
|
||||
|
||||
<span class="org-target" id="org-target--sec-control-topology"></span>
|
||||
### Controller Topology {#sec:control_topology}
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1897,9 +1883,7 @@ For a fully parallel manipulator such as the Stewart-Gough platform, this mappin
|
||||
\\[ \bm{\mathcal{F}} = \bm{J}^T \bm{\tau}; \quad \bm{\tau} = \bm{J}^{-T} \bm{\mathcal{F}} \\]
|
||||
|
||||
|
||||
### Motion Control in Task Space {#motion-control-in-task-space}
|
||||
|
||||
<span class="org-target" id="org-target--sec-control-task-space"></span>
|
||||
### Motion Control in Task Space {#sec:control_task_space}
|
||||
|
||||
|
||||
#### Decentralized PD Control {#decentralized-pd-control}
|
||||
@@ -2043,9 +2027,9 @@ These are the reasons why, in practice, IDC control is extended to different for
|
||||
|
||||
To develop the simplest possible implementable IDC, let us recall dynamic formulation complexities:
|
||||
|
||||
- the manipulator mass matrix \\(\bm{M}(\bm{\mathcal{X}})\\) is derived from kinetic energy of the manipulator (Eq. \ref{eq:kinetic\_energy})
|
||||
- the gravity vector \\(\bm{G}(\bm{\mathcal{X}})\\) is derived from potential energy (Eq. \ref{eq:gravity\_vectory})
|
||||
- the Coriolis and centrifugal matrix \\(\bm{C}(\bm{\mathcal{X}}, \dot{\bm{\mathcal{X}}})\\) is derived from Eq. \ref{eq:gravity\_vectory}
|
||||
- the manipulator mass matrix \\(\bm{M}(\bm{\mathcal{X}})\\) is derived from kinetic energy of the manipulator (Eq. \eqref{eq:kinetic\_energy})
|
||||
- the gravity vector \\(\bm{G}(\bm{\mathcal{X}})\\) is derived from potential energy (Eq. \eqref{eq:gravity\_vectory})
|
||||
- the Coriolis and centrifugal matrix \\(\bm{C}(\bm{\mathcal{X}}, \dot{\bm{\mathcal{X}}})\\) is derived from Eq. \eqref{eq:gravity\_vectory}
|
||||
|
||||
The computation of the Coriolis and centrifugal matrix is more intensive than that of the mass matrix.
|
||||
Gravity vector is more easily computable.
|
||||
@@ -2053,7 +2037,7 @@ Gravity vector is more easily computable.
|
||||
However, it is shown that certain properties hold for mass matrix, gravity vector and Coriolis and centrifugal matrix, which might be directly used in the control techniques developed for parallel manipulators.
|
||||
One of the most important properties of dynamic matrices is the skew-symmetric property of the matrix \\(\dot{\bm{M}} - 2 \bm{C}\\) .<br />
|
||||
|
||||
Consider dynamic formulation of parallel robot given in Eq. \ref{eq:closed\_form\_dynamic\_formulation}, in which the skew-symmetric property of dynamic matrices is satisfied.
|
||||
Consider dynamic formulation of parallel robot given in Eq. \eqref{eq:closed\_form\_dynamic\_formulation}, in which the skew-symmetric property of dynamic matrices is satisfied.
|
||||
The simplest form of IDC control effort \\(\bm{\mathcal{F}}\\) consists of:
|
||||
\\[ \bm{\mathcal{F}} = \bm{\mathcal{F}}\_{pd} + \bm{\mathcal{F}}\_{fl} \\]
|
||||
in which the first term \\(\bm{\mathcal{F}}\_{pd}\\) is generated by the simplified PD form on the motion error:
|
||||
@@ -2091,7 +2075,7 @@ A global understanding of the trade-offs involved in each method is needed to em
|
||||
|
||||
Various sources of uncertainties such as unmodelled dynamics, unknown parameters, calibration error, unknown disturbance wrenches, and varying payloads may exist, and are not seen in dynamic model of the manipulator.
|
||||
|
||||
To consider these modeling uncertainty in the closed-loop performance of the manipulator, recall the general closed-form dynamic formulation of the manipulator given in Eq. \ref{eq:closed\_form\_dynamic\_formulation}, and modify the inverse dynamics control input \\(\bm{\mathcal{F}}\\) as
|
||||
To consider these modeling uncertainty in the closed-loop performance of the manipulator, recall the general closed-form dynamic formulation of the manipulator given in Eq. \eqref{eq:closed\_form\_dynamic\_formulation}, and modify the inverse dynamics control input \\(\bm{\mathcal{F}}\\) as
|
||||
|
||||
\begin{align\*}
|
||||
\bm{\mathcal{F}} &= \hat{\bm{M}}(\bm{\mathcal{X}}) \bm{a}\_r + \hat{\bm{C}}(\bm{\mathcal{X}}, \dot{\bm{\mathcal{X}}}) \dot{\bm{\mathcal{X}}} + \hat{\bm{G}}(\bm{\mathcal{X}})\\\\
|
||||
@@ -2127,10 +2111,10 @@ is a measure of modeling uncertainty.
|
||||
|
||||
### Motion Control in Joint Space {#motion-control-in-joint-space}
|
||||
|
||||
Although the motion control schemes developed in section are very effective for tracking performance, they suffer from an implementation constraint that the motion variable \\(\bm{\mathcal{X}}\\) must be measured in practice.<br />
|
||||
Although the motion control schemes developed in section [Motion Control in Task Space](#sec:control_task_space) are very effective for tracking performance, they suffer from an implementation constraint that the motion variable \\(\bm{\mathcal{X}}\\) must be measured in practice.<br />
|
||||
|
||||
If this measurement is available without any doubt, such topologies are among the best routines to be implemented in practice.
|
||||
However, as explained in Section , in many practical situations measurement of the motion variable \\(\bm{\mathcal{X}}\\) is difficult or expensive, and usually just the active joint variables \\(\bm{q}\\) are measured.
|
||||
However, as explained in Section [Controller Topology](#sec:control_topology), in many practical situations measurement of the motion variable \\(\bm{\mathcal{X}}\\) is difficult or expensive, and usually just the active joint variables \\(\bm{q}\\) are measured.
|
||||
In such cases, the controllers developed in the joint space may be recommended for practical implementation.<br />
|
||||
|
||||
To generate a direct input to output relation in the joint space, consider the topology depicted in [Figure 16](#figure--fig:general-topology-motion-feedback-bis).
|
||||
@@ -2183,7 +2167,7 @@ with:
|
||||
|
||||
</div>
|
||||
|
||||
Equation \ref{eq:dynamics\_joint\_space} represents the closed form dynamic formulation of a general parallel robot in the joint space.<br />
|
||||
Equation \eqref{eq:dynamics\_joint\_space} represents the closed form dynamic formulation of a general parallel robot in the joint space.<br />
|
||||
|
||||
Note that the dynamic matrices are **not** explicitly represented in terms of the joint variable vector \\(\bm{q}\\).
|
||||
In fact, to fully derive these matrices, the Jacobian matrices must be computed and are generally derived as a function of the motion variables \\(\bm{\mathcal{X}}\\).
|
||||
@@ -2301,7 +2285,7 @@ However, note that for a good performance, an **accurate model of the system is
|
||||
### Summary of Motion Control Techniques {#summary-of-motion-control-techniques}
|
||||
|
||||
In this section, a number of control techniques have been developed for parallel robots.
|
||||
Based on the dynamic formulation given in Section , many **model-based** control techniques have been developed for implementation in the task space as well as in the joint space.
|
||||
Based on the dynamic formulation given in Section [Dynamics](#sec:dynamics), many **model-based** control techniques have been developed for implementation in the task space as well as in the joint space.
|
||||
These control techniques are presented from the simplest form of decentralized PD control to more advanced robust and adaptive inverse dynamics control.
|
||||
|
||||
A summary of these techniques is given below.
|
||||
@@ -2545,9 +2529,7 @@ Furthermore, a very small error signature in the joint space may be accumulated
|
||||
Hence, it is recommended to design and implement controllers in the task space, if the required motion variables can be directly measured or the forward kinematic solution can be calculated in an online routine.
|
||||
|
||||
|
||||
## Force Control {#force-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-force-control"></span>
|
||||
## Force Control {#sec:force:control}
|
||||
|
||||
|
||||
### Introduction {#introduction}
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Ultra Precision Bearings"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = true
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
|
||||
@@ -182,7 +182,7 @@ In saturation, \\(u\_m\\) is a constant and the resulting equations drive \\(u\\
|
||||
### [Bumpless Transfer]({{< relref "bumpless_transfer.md" >}}) {#bumpless-transfer--bumpless-transfer-dot-md}
|
||||
|
||||
When switching on the regulator, significant transient behavior can be seen and the controller may saturate the actuators.
|
||||
The solution is similar to that of the wind-up phenomenon: the regulator should be always on, carrying out calculations by using \ref{eq:antiwindup\_pid}.
|
||||
The solution is similar to that of the wind-up phenomenon: the regulator should be always on, carrying out calculations by using \eqref{eq:antiwindup\_pid}.
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
@@ -54,7 +54,7 @@ Here, we focus on the control of linear time invariant electromechanical motion
|
||||
The dynamics of such systems are often dominated by the mechanics, such that:
|
||||
|
||||
\begin{equation}
|
||||
G\_p(s) = \sum\_{i=1}^{N\_{rb}} \frac{c\_i b\_i^T}{s^2} + \sum\_{i=N\_{rb} + 1}^{N} \frac{c\_ib\_i^T}{s^2 + 2 \xi\_i \omega\_i s + \omega\_i^2}
|
||||
G\_p(s) = \sum\_{i=1}^{N\_{rb}} \frac{c\_i b\_i^T}{s^2} + \sum\_{i=N\_{rb} + 1}^{N} \frac{c\_ib\_i^T}{s^2 + 2 \zeta\_i \omega\_i s + \omega\_i^2}
|
||||
\end{equation}
|
||||
|
||||
with \\(N\_{rb}\\) is the number of rigid body modes.
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Active damping of vibrations in high-precision motion systems"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
draft = true
|
||||
ref_author = "Babakhani, B."
|
||||
ref_year = 2012
|
||||
+++
|
||||
|
||||
@@ -195,8 +195,8 @@ If the PSD is given as a function \\(S\_x(j\omega)\\), the disturbance filter ca
|
||||
> Given a positive even function \\(S\_x(f)\\) of finite area, find a minimum-phase stable function \\(L(s)\\), such that \\(|L(j2\pi f)|^2 = S(s)\\)
|
||||
|
||||
**Harmonic signals** can be approximately modeled by filtering white noise with a badly damped second order system, having a \\(+1\\) slope below the resonance frequency and a \\(-1\\) slope above the resonance frequency:
|
||||
\\[ V\_h = \frac{s}{s^2 + 2 \xi \omega\_h + \omega\_h^2} \\]
|
||||
with \\(\xi\\) the relative damping and \\(\omega\_h\\) the resonance frequency [rad/s].
|
||||
\\[ V\_h = \frac{s}{s^2 + 2 \zeta \omega\_h + \omega\_h^2} \\]
|
||||
with \\(\zeta\\) the relative damping and \\(\omega\_h\\) the resonance frequency [rad/s].
|
||||
By making the \\(\mathcal{H}\_2\\) norm of \\(V\_h\\) equal to the RMS-value of the harmonic signal, the propagation of the disturbance to the performance channel can be well approximated.
|
||||
|
||||
|
||||
@@ -233,3 +233,10 @@ By calculation \\(\mathcal{H}\_2\\) optimal controllers for increasing \\(\alpha
|
||||
> To use the measured PSDs in an optimal control design, such as H2-control, the disturbances must be modelled using linear time invariant models with multiple white noise input.
|
||||
> To derive such models, spectral factorization is used.
|
||||
> It is recommended to investigate which methods for spectral factorization are currently available and numerically robust.
|
||||
|
||||
|
||||
## Bibliography {#bibliography}
|
||||
|
||||
<style>.csl-entry{text-indent: -1.5em; margin-left: 1.5em;}</style><div class="csl-bib-body">
|
||||
<div class="csl-entry"><a id="citeproc_bib_item_1"></a>Jabben, Leon. 2007. “Mechatronic Design of a Magnetically Suspended Rotating Platform.” Delft University.</div>
|
||||
</div>
|
||||
@@ -131,7 +131,7 @@ Define a new input and a new output:
|
||||
u\_1 = J^T f\_m, \quad y = J^{-1} (l - l\_r)
|
||||
\end{equation}
|
||||
|
||||
Equation \ref{eq:hexapod\_eq\_motion} can be rewritten as:
|
||||
Equation \eqref{eq:hexapod\_eq\_motion} can be rewritten as:
|
||||
|
||||
\begin{equation} \label{eq:hexapod\_eq\_motion\_decoup\_1}
|
||||
\begin{split}
|
||||
|
||||
@@ -335,17 +335,17 @@ These eigenvectors have the following orthogonality properties, or can always be
|
||||
\phi\_i^T M \phi\_j = 0 \quad (i \neq j)
|
||||
\end{equation}
|
||||
|
||||
For \\(i=j\\) the result of the multiplication according to equation \ref{eq:eigenvector\_orthogonality\_mass} yields a non-zero result, which is normally indicated as **modal mass** \\(\mathit{m}\_i\\):
|
||||
For \\(i=j\\) the result of the multiplication according to equation \eqref{eq:eigenvector\_orthogonality\_mass} yields a non-zero result, which is normally indicated as **modal mass** \\(\mathit{m}\_i\\):
|
||||
|
||||
\begin{equation} \label{eq:modal\_mass}
|
||||
\phi\_i^T M \phi\_i = \mathit{m}\_i
|
||||
\end{equation}
|
||||
|
||||
Because only the direction but not the length of an eigenvector is defined, several scaling methods are used, all based on equation \ref{eq:modal\_mass:}
|
||||
Because only the direction but not the length of an eigenvector is defined, several scaling methods are used, all based on equation \eqref{eq:modal\_mass:}
|
||||
|
||||
- \\(|\phi\_i| = 1\\). Each eigenvector \\(\phi\_i\\) is scaled such that its length is equal to \\(1\\). The modal mass are then calculated from equation \ref{eq:modal\_mass}.
|
||||
- \\(\max(\phi\_i) = 1\\). Each eigenvector \\(\phi\_i\\) is scaled such that its largest element is equation to \\(1\\). The modal mass is then calculated from equation \ref{eq:modal\_mass}.
|
||||
- \\(m\_i = 1\\). The modal mass \\(\mathit{m}\_i\\) is set to \\(1\\). The scaling of the mode vector \\(\phi\_i\\) follows from equation \ref{eq:modal\_mass}.
|
||||
- \\(|\phi\_i| = 1\\). Each eigenvector \\(\phi\_i\\) is scaled such that its length is equal to \\(1\\). The modal mass are then calculated from equation \eqref{eq:modal\_mass}.
|
||||
- \\(\max(\phi\_i) = 1\\). Each eigenvector \\(\phi\_i\\) is scaled such that its largest element is equation to \\(1\\). The modal mass is then calculated from equation \eqref{eq:modal\_mass}.
|
||||
- \\(m\_i = 1\\). The modal mass \\(\mathit{m}\_i\\) is set to \\(1\\). The scaling of the mode vector \\(\phi\_i\\) follows from equation \eqref{eq:modal\_mass}.
|
||||
|
||||
The orthogonality properties also apply to the stiffness matrix \\(K\\):
|
||||
|
||||
@@ -450,7 +450,7 @@ In such an analysis one is typically interested in the transfer function between
|
||||
Applying the principle of modal decomposition, any transfer function can be derived by first calculating the behavior of the individual modes, and then **summing all modal contributions**.
|
||||
|
||||
The contribution of one single mode \\(i\\) to the transfer function \\(x\_l/f\_k\\) can be derived by first considering the response of the modal DoF \\(q\_i\\) to a force vector \\(f\\) with only one non-zero component \\(f\_k\\).
|
||||
In that case, equation \ref{eq:eoq\_modal\_i} is reduced to:
|
||||
In that case, equation \eqref{eq:eoq\_modal\_i} is reduced to:
|
||||
|
||||
\begin{equation}
|
||||
m\_i \ddot{q}\_i(t) + k\_i q\_i(t) = \phi\_{ik} f\_k(t)
|
||||
@@ -481,7 +481,7 @@ The overall transfer function can be found by summation of the individual modal
|
||||
|
||||
### Graphical Representation {#graphical-representation}
|
||||
|
||||
Due to the equivalence with the differential equations of a single mass spring system, equation \ref{eq:eoq\_modal\_i} is often represented by a single mass spring system on which a force \\(f^\prime = \phi\_i^T f\\) acts.
|
||||
Due to the equivalence with the differential equations of a single mass spring system, equation \eqref{eq:eoq\_modal\_i} is often represented by a single mass spring system on which a force \\(f^\prime = \phi\_i^T f\\) acts.
|
||||
However, this representation implies an important loss of information because it neglects all information about the mode-shape vector.
|
||||
|
||||
Consider the system in [Figure 8](#figure--fig:rankers98-mode-trad-representation) for which the three mode shapes are depicted in the traditional graphical representation.
|
||||
@@ -516,7 +516,7 @@ The resulting moment of inertia \\(J\_i\\) of the i-th modal lever then is:
|
||||
J\_i = \sum\_{k=1}^n m\_k \phi\_{ik}^2
|
||||
\end{equation}
|
||||
|
||||
This result is identical to the modal mass \\(m\_i\\) found with Equation \ref{eq:modal\_mass}, because the mass matrix \\(M\\) is a diagonal matrix of physical masses \\(m\_k\\), and consequently the expression for the modal mass \\(m\_i\\) yields:
|
||||
This result is identical to the modal mass \\(m\_i\\) found with Equation \eqref{eq:modal\_mass}, because the mass matrix \\(M\\) is a diagonal matrix of physical masses \\(m\_k\\), and consequently the expression for the modal mass \\(m\_i\\) yields:
|
||||
|
||||
\begin{equation}
|
||||
m\_i = \phi\_j^T M \phi\_j = \sum\_{k=1}^n m\_k \phi\_{ik}^2
|
||||
@@ -637,7 +637,7 @@ whereas the modal stiffnesses follow from \\(k\_i = \omega\_i^2 m\_i\\).
|
||||
|
||||
{{< figure src="/ox-hugo/rankers98_example_2dof_modal.png" caption="<span class='figure-number'>Figure 15: </span>Graphical representation of modes and modal parameters of the two mass spring system" >}}
|
||||
|
||||
From these results, the effective modal parameters for each mode, and for each individual DoF can be defined using equations \ref{eq:m\_modal\_eff} and \ref{eq:k\_modal\_eff}.
|
||||
From these results, the effective modal parameters for each mode, and for each individual DoF can be defined using equations \eqref{eq:m\_modal\_eff} and \eqref{eq:k\_modal\_eff}.
|
||||
The results are summarized in [Table 2](#table--tab:2dof-example-modal-params-eff).
|
||||
|
||||
<a id="table--tab:2dof-example-modal-params-eff"></a>
|
||||
@@ -716,7 +716,7 @@ f\_{\text{new},i}(\Delta k) &= \frac{1}{2\pi}\sqrt{\frac{k\_{\text{eff},i} + \De
|
||||
Let's use the two mass spring system in [Figure 14](#figure--fig:rankers98-example-2dof) as an example.
|
||||
|
||||
In order to analyze the effect of an extra mass at \\(x\_2\\), the effective modal mass at that DoF needs to be known for both modes (see [Table 2](#table--tab:2dof-example-modal-params-eff)).
|
||||
Then using equation \ref{eq:sensitivity\_add\_m}, one can estimate the effect of an extra mass \\(\Delta m = 1 kg\\) added to \\(m\_2\\).
|
||||
Then using equation \eqref{eq:sensitivity\_add\_m}, one can estimate the effect of an extra mass \\(\Delta m = 1 kg\\) added to \\(m\_2\\).
|
||||
|
||||
To estimate the influence of extra stiffness between the two DoF, one needs to calculate the effective modal stiffness that corresponds to the relative motion between \\(x\_2\\) and \\(x\_1\\).
|
||||
This can be graphically done as shown in [Figure 19](#figure--fig:rankers98-example-sensitivity-2dof):
|
||||
@@ -726,7 +726,7 @@ k\_{\text{eff},1,(2-1)} &= 0.46 \cdot 10^7 / 0.07^2 = 93.9 \cdot 10^7 N/m \\\\
|
||||
k\_{\text{eff},2,(2-1)} &= 1.23 \cdot 10^7 / 1.1^2 = 1.0 \cdot 10^7 N/m
|
||||
\end{align}
|
||||
|
||||
And using equation \ref{eq:sensitivity\_add\_m}, the effect of additional stiffness on the frequency of the two modes can be computed.
|
||||
And using equation \eqref{eq:sensitivity\_add\_m}, the effect of additional stiffness on the frequency of the two modes can be computed.
|
||||
|
||||
The results are summarized in [Table 3](#table--tab:example-sensitivity-2dof-results).
|
||||
|
||||
@@ -860,13 +860,13 @@ Let's introduce a variable \\(\alpha\\), which **relates the high-frequency cont
|
||||
\alpha = \frac{\frac{\phi\_{i,\text{servo}} \phi\_{i,\text{force}}}{m\_i}}{\frac{1}{m}}
|
||||
\end{equation}
|
||||
|
||||
which simplifies equation \ref{eq:effect\_one\_mode} to:
|
||||
which simplifies equation \eqref{eq:effect\_one\_mode} to:
|
||||
|
||||
\begin{equation} \label{eq:effect\_one\_mode\_simplified}
|
||||
\boxed{\frac{x\_{\text{servo}}}{F\_{\text{servo}}} = \frac{1}{ms^2} + \frac{\alpha}{m s^2 + m \omega\_i^2}}
|
||||
\end{equation}
|
||||
|
||||
Equation \ref{eq:effect\_one\_mode\_simplified} will be the basis for the discussion of the various patterns that can be observe in the frequency response functions and the effect of resonances on servo stability.
|
||||
Equation \eqref{eq:effect\_one\_mode\_simplified} will be the basis for the discussion of the various patterns that can be observe in the frequency response functions and the effect of resonances on servo stability.
|
||||
|
||||
Three different types of intersection pattern can be found in the amplitude plot as shown in [Figure 25](#figure--fig:rankers98-frf-effect-alpha).
|
||||
Depending on the absolute value of \\(\alpha\\) one can observe:
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
+++
|
||||
title = "Robust mass damper design for bandwidth increase of motion stages"
|
||||
author = ["Dehaeze Thomas"]
|
||||
draft = true
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Tags
|
||||
@@ -192,7 +192,7 @@ The goal is to increase the modal damping of modes 7, 9, 10/11 and 13.
|
||||
The transfer function \\(T\_i(s)\\) is defined as the contribution of the a single mode \\(i\\) in an input/output transfer function:
|
||||
|
||||
\begin{equation}
|
||||
T\_i(s) = \frac{\phi\_i^{\text{act}} \phi\_i^{\text{sen}}}{s^2 + 2 \xi \omega\_i s + \omega\_i^2} = \frac{1}{m\_i s^2 + c\_i s + k\_i}
|
||||
T\_i(s) = \frac{\phi\_i^{\text{act}} \phi\_i^{\text{sen}}}{s^2 + 2 \zeta \omega\_i s + \omega\_i^2} = \frac{1}{m\_i s^2 + c\_i s + k\_i}
|
||||
\end{equation}
|
||||
|
||||
With \\(\phi\_i^{\text{act}}\\) and \\(\phi\_i^{\text{sen}}\\) the modal factors of the actuator and sensor.
|
||||
|
||||
@@ -87,13 +87,13 @@ Here is some inline mathematics: \\(z = 2\\).
|
||||
Unumbered equation:
|
||||
\\[ F(x) = \int\_0^x f(t) dt \\]
|
||||
|
||||
Using the `equation` environment in Eq. \ref{eq:numbered}.
|
||||
Using the `equation` environment in Eq. \eqref{eq:numbered}.
|
||||
|
||||
\begin{equation} \label{eq:numbered}
|
||||
F(s) = \int\_0^\infty f(t) e^{-st} dt
|
||||
\end{equation}
|
||||
|
||||
Using the `align` environment Equations \ref{eq:align\_1} and \ref{eq:align\_2}.
|
||||
Using the `align` environment Equations \eqref{eq:align\_1} and \eqref{eq:align\_2}.
|
||||
|
||||
\begin{align}
|
||||
\mathcal{F}(a) &= \frac{1}{2\pi i}\oint\_\gamma \frac{f(z)}{z - a}\\,dz \label{eq:align\_1} \\\\
|
||||
|
||||
@@ -0,0 +1,5 @@
|
||||
---
|
||||
title: "Projects"
|
||||
---
|
||||
|
||||
Here are personal and professional projects that are all open-source / open hardware.
|
||||
|
After Width: | Height: | Size: 395 KiB |
|
After Width: | Height: | Size: 124 KiB |
@@ -0,0 +1,109 @@
|
||||
---
|
||||
title: "Inverted Pendulum on a Recycled 3D Printer"
|
||||
summary: "A pendulum balanced upright on a motorised cart, built from the axis of an old 3D printer and controlled by a Teensy 4.1 at 1 kHz."
|
||||
tags: ["Hardware", "Software", "Control"]
|
||||
status: "Completed"
|
||||
date: 2026-03-22
|
||||
repo: "https://github.com/tdehaeze/inverted-pendulum"
|
||||
cover: "cover.jpg"
|
||||
---
|
||||
|
||||
## Overview
|
||||
|
||||
This project is a classic control demonstrator: a rigid pendulum is mounted on a cart and kept upright by moving the cart back and forth.
|
||||
The mechanics come from a recycled 3D printer (Alfawise U20): one of its linear axes, with the stepper motor and belt, carries the pendulum pivot.
|
||||
A quadrature encoder measures the pendulum angle, and a Teensy 4.1 microcontroller runs the feedback loop at 1 kHz.
|
||||
A small PyQt5 application on the computer is used to select the controller, change the gains and setpoints, and record data.
|
||||
|
||||
{{< figure src="cover.jpg" alt="Photo of the inverted pendulum setup with its main parts labelled" caption="The setup: cart on a belt-driven rail, stepper motor, pendulum encoder and the electronics (labels in French)." >}}
|
||||
|
||||
## Hardware
|
||||
|
||||
| Component | Details |
|
||||
|-----------|---------|
|
||||
| Microcontroller | Teensy 4.1 |
|
||||
| Stepper motor | DRV8825 driver, 32 microsteps, 5 µm per step |
|
||||
| Pendulum encoder | Quadrature, 4096 steps per revolution (0.088° per step) |
|
||||
| Cart travel | ±200 mm hard stop, ±160 mm soft limit |
|
||||
| Control rate | 1 kHz, driven by a hardware timer (`IntervalTimer`) |
|
||||
|
||||
The cart input is an acceleration command.
|
||||
It is integrated to a velocity inside the 1 kHz interrupt, and converted into step pulses for the motor driver.
|
||||
The pendulum angular velocity is estimated by finite difference of the encoder reading.
|
||||
A soft limit blocks accelerations towards the end of the rail, and a hard stop at ±200 mm cuts the motor.
|
||||
|
||||
## Software
|
||||
|
||||
The repository has three parts:
|
||||
|
||||
- **`teensy/`**: firmware (PlatformIO / Arduino framework). Runs the control loop, drives the motor, reads the encoder and streams telemetry over USB serial.
|
||||
- **`gui/`**: PyQt5 and pyqtgraph application. Sends text commands to the Teensy (`MODE PD`, `SET KP 12`, `FB ON`, ...), plots the telemetry live and saves it to CSV.
|
||||
- **`model/` and `tools/`**: Python scripts for simulation, controller design, model identification and plotting experiments.
|
||||
|
||||
## Model and identification
|
||||
|
||||
With φ = θ − π the angle from the upright position and u the cart acceleration, the linearised dynamics around the upright position are:
|
||||
|
||||
```
|
||||
D·φ̈ + c·φ̇ − m·g·l·φ = m·l·u
|
||||
```
|
||||
|
||||
where D is the effective inertia of the pendulum about its pivot.
|
||||
The state is [x, ẋ, φ, φ̇] and the input is the cart acceleration.
|
||||
|
||||
The pendulum length and friction coefficient are identified from a free oscillation: the pendulum hangs down, receives a small push, and the decaying oscillation is recorded for 10 to 50 seconds.
|
||||
A Nelder-Mead fit (`tools/fit.py`) then adjusts the model to the measurement.
|
||||
|
||||
| Parameter | Symbol | Value |
|
||||
|-----------|--------|-------|
|
||||
| Pendulum mass | m | 0.1 kg |
|
||||
| Half length (pivot to centre of mass) | l | 0.326 m |
|
||||
| Friction coefficient | c | 3.4 × 10⁻⁴ N·m·s/rad |
|
||||
|
||||
{{< figure src="identification-fit.png" alt="Measured and fitted free oscillation of the pendulum" caption="Free oscillation of the pendulum: measurement and fitted model (figure labels in French)." >}}
|
||||
|
||||
{{< video src="identification.mp4" caption="Free oscillation used for the identification." >}}
|
||||
|
||||
## Controllers
|
||||
|
||||
All gains are in SI units, and the controller output is the cart acceleration.
|
||||
|
||||
- **P**: u = −Kp · φ
|
||||
- **PD**: u = −Kp · φ − Kd · φ̇
|
||||
- **LQR**: u = −K · [x, ẋ, φ, φ̇]
|
||||
|
||||
The LQR gain vector K is computed in Python (`model/inverted_pendulum.py`, using the `control` library) from weights on the four states and on the input, then entered in the GUI.
|
||||
|
||||
### PD control
|
||||
|
||||
A PD controller can hold the pendulum angle at zero, but it does not see the cart position.
|
||||
In the experiment below the angle is regulated while the cart drifts until it reaches the end of the rail and the pendulum falls.
|
||||
The same controller with other gains acts mostly as a damper: it slows down the pendulum without fully stabilising it.
|
||||
|
||||
{{< figure src="pd-simulation.png" alt="Simulated PD response of the pendulum angle" caption="Simulated PD response, from a 5° initial angle (figure labels in French)." >}}
|
||||
|
||||
{{< figure src="pd-experiment.png" alt="Measured angle and cart position with a PD controller" caption="Measured PD experiment: the angle is held near zero while the cart drifts to the end stop (figure labels in French)." >}}
|
||||
|
||||
{{< video src="pd-control.mp4" caption="PD control: the pendulum is stabilised, the cart slowly drifts." >}}
|
||||
|
||||
{{< video src="pd-damping.mp4" caption="PD control used as a damper only: the pendulum dynamics are slowed down." >}}
|
||||
|
||||
### LQR control
|
||||
|
||||
The LQR feeds back the cart position and velocity as well as the pendulum angle and angular velocity.
|
||||
This keeps the cart near its setpoint while the pendulum stays upright.
|
||||
Higher weights on the states give faster corrections, at the cost of more aggressive cart motion.
|
||||
|
||||
{{< video src="lqr.mp4" caption="LQR with a higher gain: angle and cart position are controlled together." >}}
|
||||
|
||||
{{< video src="lqr-setpoint-step.mp4" caption="LQR following a step in the cart position setpoint while keeping the pendulum upright." >}}
|
||||
|
||||
## Typical workflow
|
||||
|
||||
1. Flash the firmware with `pio run -e teensy41 -t upload` from `teensy/`.
|
||||
2. Start the GUI (`python gui/program.py`), enable the motor and zero the cart and encoder.
|
||||
3. Record a free oscillation (`tools/capture.py`) and fit the model parameters (`tools/fit.py`).
|
||||
4. Pick a controller in the GUI, enter the gains, bring the pendulum close to upright and switch the feedback on.
|
||||
5. Save the data to CSV and plot it with `tools/plot_experiment.py`.
|
||||
|
||||
The full instructions and serial command list are in the [README](https://github.com/tdehaeze/inverted-pendulum).
|
||||
|
After Width: | Height: | Size: 62 KiB |
|
After Width: | Height: | Size: 42 KiB |
@@ -0,0 +1,53 @@
|
||||
---
|
||||
title: "rtint-gui: Desktop GUI for Real-Time Control"
|
||||
summary: "A desktop application to acquire signals, identify plant dynamics and design feedback control on a real-time target."
|
||||
tags: ["Software", "Control"]
|
||||
status: "Active"
|
||||
date: 2026-09-01
|
||||
repo: "https://gitlab.esrf.fr/dehaeze/real-time-interface-gui"
|
||||
docs: "https://dehaeze.gitlab-pages.esrf.fr/real-time-interface-gui/"
|
||||
pypi: "https://pypi.org/project/rtint-gui/"
|
||||
---
|
||||
<!-- TODO: confirm public URL -->
|
||||
<!-- TODO: add GUI screenshots (e.g. Signal Analysis, Dynamical Identification, Feedback Control Design) -->
|
||||
|
||||
## Overview
|
||||
|
||||
`rtint-gui` is a desktop application for working with a real-time target that runs a Resyst server.
|
||||
It is built on top of [rtint]({{< relref "real-time-interface" >}}), which handles the communication with the target, and follows the usual steps of a control task:
|
||||
|
||||
1. **Connect** to a running server.
|
||||
2. **Acquire** signals from the target.
|
||||
3. **Analyse** the records as time traces and spectra (PSD / ASD).
|
||||
4. **Identify** the plant dynamics by measuring frequency responses.
|
||||
5. **Design** feedback control from the identified dynamics.
|
||||
|
||||
Each step is a page of the application.
|
||||
|
||||
## Pages
|
||||
|
||||
- **Signal Analysis**: choose counters and model signals, set a duration, watch the acquisition live, then compute power spectra with configurable window, overlap and averaging.
|
||||
- **Dynamical Identification**: excite the plant with a generator and estimate its frequency response (Bode plot, coherence, and an RGA plot for multi-input multi-output systems). Open-loop and closed-loop identification are supported.
|
||||
- **Transfer Function Analysis**: overlay measured responses with the Bode plots of the filters running on the target, and with their products.
|
||||
- **Feedback Control Design**: from an identified plant and the filters used as controller, compute characteristic loci, sensitivity and complementary sensitivity, the modulus margin and a Nyquist stability verdict.
|
||||
- **Filters, motors, EtherCAT, parameters and more**: inspect and edit what the real-time model exposes.
|
||||
|
||||
Results are saved as MATLAB `.mat` files, so they can be reopened in MATLAB or Python.
|
||||
The analysis pages also work offline on previously saved data, without a target.
|
||||
|
||||
## Installation
|
||||
|
||||
```bash
|
||||
pipx install rtint-gui # or: uv tool install rtint-gui
|
||||
rtint-gui
|
||||
```
|
||||
|
||||
Python 3.12 or 3.13 is required.
|
||||
The interface uses PySide6 and pyqtgraph.
|
||||
Running `rtint-gui --offline` starts it without a real-time target.
|
||||
|
||||
The [documentation](https://dehaeze.gitlab-pages.esrf.fr/real-time-interface-gui/) has a guide for each page and a description of the `.mat` file format.
|
||||
|
||||
## Related
|
||||
|
||||
- [rtint]({{< relref "real-time-interface" >}}): the Python package this application is built on.
|
||||
@@ -0,0 +1,65 @@
|
||||
---
|
||||
title: "rtint: Python Interface to Real-Time Targets"
|
||||
summary: "A Python package to control and monitor Simulink models running on a real-time target machine, such as a Speedgoat."
|
||||
tags: ["Software", "Control"]
|
||||
status: "Active"
|
||||
date: 2026-10-01
|
||||
repo: "https://gitlab.esrf.fr/dehaeze/real-time-interface"
|
||||
pypi: "https://pypi.org/project/rtint/"
|
||||
---
|
||||
<!-- TODO: confirm public URL -->
|
||||
|
||||
## Overview
|
||||
|
||||
`rtint` is a Python package that talks to Simulink models running on a real-time target machine, through a Resyst server.
|
||||
It wraps the server's client API so that the parts of a real-time model (motors, filters, feedback loops, signals and so on) can be used as ordinary Python objects from a script or an interactive session.
|
||||
|
||||
It is used at the ESRF to commission and tune mechatronic systems whose control runs on a real-time target.
|
||||
For a graphical front end built on top of it, see [rtint-gui]({{< relref "real-time-interface-gui" >}}).
|
||||
|
||||
## What it covers
|
||||
|
||||
Each part of the real-time model has its own controller object, available as an attribute of the main `RtintController`:
|
||||
|
||||
- **Motors**: start, stop, move and read the state.
|
||||
- **Regulation**: switch feedback loops on and off.
|
||||
- **Filters**: read and change filter parameters, for example low-pass, PID and notch filters, and compute their frequency responses.
|
||||
- **Signals and parameters**: read and write model signals and tunable parameters.
|
||||
- **Acquisition**: record signals at the model sampling rate.
|
||||
- **Signal generators**: sine, chirp and other excitation signals, useful for system identification.
|
||||
- **Triggers, lookup tables, EtherCAT slaves and 2D scans.**
|
||||
|
||||
Most objects can print a summary table of their state in the terminal.
|
||||
|
||||
## Example
|
||||
|
||||
```python
|
||||
from rtint.rtint_hardware import RtintController
|
||||
|
||||
config = {
|
||||
"server": "my-server-hostname",
|
||||
"port": 8080,
|
||||
}
|
||||
|
||||
controller = RtintController("my_target", config)
|
||||
controller._run_model("my_model")
|
||||
|
||||
# Access hardware components
|
||||
controller.motor.start()
|
||||
controller.regul.on()
|
||||
controller.filter.low_pass(wn=100, xi=0.707)
|
||||
```
|
||||
|
||||
## Installation
|
||||
|
||||
```bash
|
||||
pip install rtint
|
||||
```
|
||||
|
||||
Python 3.9 to 3.13 is supported.
|
||||
The package depends on `resyst-client`, `numpy`, `scipy`, `matplotlib`, `gevent`, `treelib` and `tabulate`.
|
||||
A running Resyst server and a real-time model are needed to do anything useful with it.
|
||||
|
||||
## Related
|
||||
|
||||
- [rtint-gui]({{< relref "real-time-interface-gui" >}}): desktop application built on this package.
|
||||
@@ -24,26 +24,22 @@ When possible, Matlab scripts used for the example/exercises are provided such t
|
||||
|
||||
The general structure of this document is as follows:
|
||||
|
||||
- A short introduction to _model based control_ is given in Section
|
||||
- Classical _open_ loop shaping method is presented in Section .
|
||||
- A short introduction to _model based control_ is given in Section [Introduction to Model Based Control](#sec:model_based_control)
|
||||
- Classical _open_ loop shaping method is presented in Section [Classical Open Loop Shaping](#sec:open_loop_shaping).
|
||||
It is also shown that \\(\mathcal{H}\_\infty\\) synthesis can be used for _open_ loop shaping
|
||||
- Important concepts indispensable for \\(\mathcal{H}\_\infty\\) control such as the \\(\mathcal{H}\_\infty\\) norm and the generalized plant are introduced in Section
|
||||
- A very important step in \\(\mathcal{H}\_\infty\\) control is to express the control specifications (performances, robustness, etc.) as an \\(\mathcal{H}\_\infty\\) optimization problem. Such procedure is described in Section
|
||||
- Important concepts indispensable for \\(\mathcal{H}\_\infty\\) control such as the \\(\mathcal{H}\_\infty\\) norm and the generalized plant are introduced in Section [A first Step into the \\(\mathcal{H}\_\infty\\) world](#sec:h_infinity_introduction)
|
||||
- A very important step in \\(\mathcal{H}\_\infty\\) control is to express the control specifications (performances, robustness, etc.) as an \\(\mathcal{H}\_\infty\\) optimization problem. Such procedure is described in Section [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification)
|
||||
- One of the most useful use of the \\(\mathcal{H}\_\infty\\) control is the shaping of closed-loop transfer functions.
|
||||
Such technique is presented in Section
|
||||
- Finally, complete examples of the use of \\(\mathcal{H}\_\infty\\) Control for practical problems are provided in Section
|
||||
Such technique is presented in Section [\\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions](#sec:closed-loop-shaping)
|
||||
- Finally, complete examples of the use of \\(\mathcal{H}\_\infty\\) Control for practical problems are provided in Section [Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control - Example](#sec:h_infinity_mixed_sensitivity)
|
||||
|
||||
|
||||
## Introduction to Model Based Control {#introduction-to-model-based-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-model-based-control"></span>
|
||||
## Introduction to Model Based Control {#sec:model_based_control}
|
||||
|
||||
|
||||
### Model Based Control - Methodology {#model-based-control-methodology}
|
||||
### Model Based Control - Methodology {#sec:model_based_control_methodology}
|
||||
|
||||
<span class="org-target" id="org-target--sec-model-based-control-methodology"></span>
|
||||
|
||||
The typical methodology for **Model Based Control** techniques is schematically shown in Figure [Figure 1](#figure--fig:control-procedure).
|
||||
The typical methodology for **Model Based Control** techniques is schematically shown in [Figure 1](#figure--fig:control-procedure).
|
||||
|
||||
It consists of three steps:
|
||||
|
||||
@@ -59,14 +55,12 @@ It consists of three steps:
|
||||
|
||||
In this document, we will suppose a model of the plant is available (step 1 already performed), and we will focus on steps 2 and 3.
|
||||
|
||||
In Section , steps 2 and 3 will be described for a control techniques called **classical (open-)loop shaping**.
|
||||
In Section [Classical Open Loop Shaping](#sec:open_loop_shaping), steps 2 and 3 will be described for a control techniques called **classical (open-)loop shaping**.
|
||||
|
||||
Then, steps 2 and 3 for the **\\(\mathcal{H}\_\infty\\) Loop Shaping** of closed-loop transfer functions will be discussed in Sections , and .
|
||||
Then, steps 2 and 3 for the **\\(\mathcal{H}\_\infty\\) Loop Shaping** of closed-loop transfer functions will be discussed in Sections [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification), [\\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions](#sec:closed-loop-shaping) and [Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control - Example](#sec:h_infinity_mixed_sensitivity).
|
||||
|
||||
|
||||
### From Classical Control to Robust Control {#from-classical-control-to-robust-control}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comp-classical-modern-robust-control"></span>
|
||||
### From Classical Control to Robust Control {#sec:comp_classical_modern_robust_control}
|
||||
|
||||
Many different model based control techniques have been developed since the birth of _classical control theory_ in the '30s.
|
||||
|
||||
@@ -84,7 +78,7 @@ By the 1980's, modern control theory was shown to have some robustness issues an
|
||||
This led to a new control theory called **Robust control** that blends the best features of classical and modern techniques.
|
||||
This robust control theory is the subject of this document.
|
||||
|
||||
The three presented control methods are compared in Table [Table 1](#table--tab:comparison-control-methods).
|
||||
The three presented control methods are compared in [Table 1](#table--tab:comparison-control-methods).
|
||||
|
||||
Note that in parallel, there have been numerous other developments, including non-linear control, adaptive control, machine-learning control just to name a few.
|
||||
|
||||
@@ -113,19 +107,17 @@ Note that in parallel, there have been numerous other developments, including no
|
||||
| | No input usage lim. | | |
|
||||
|
||||
|
||||
### Example System {#example-system}
|
||||
|
||||
<span class="org-target" id="org-target--sec-example-system"></span>
|
||||
### Example System {#sec:example_system}
|
||||
|
||||
Throughout this document, multiple examples and practical application of presented control strategies will be provided.
|
||||
Most of them will be applied on a physical system presented in this section.
|
||||
|
||||
This system is shown in Figure [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr).
|
||||
This system is shown in [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr).
|
||||
It could represent an active suspension stage supporting a payload.
|
||||
The _inertial_ motion of the payload is measured using an inertial sensor and this is feedback to a force actuator.
|
||||
Such system could be used to actively isolate the payload (disturbance rejection problem) or to make it follow a trajectory (tracking problem).
|
||||
|
||||
The notations used on Figure [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr) are listed and described in Table [Table 2](#table--tab:example-notations).
|
||||
The notations used on [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr) are listed and described in [Table 2](#table--tab:example-notations).
|
||||
|
||||
<a id="figure--fig:mech-sys-1dof-inertial-contr"></a>
|
||||
|
||||
@@ -182,11 +174,11 @@ You can follow this generic procedure:
|
||||
|
||||
</div>
|
||||
|
||||
Having obtained \\(G(s)\\) and \\(G\_d(s)\\), we can transform the system shown in Figure [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr) into a classical feedback architecture as shown in Figure [Figure 6](#figure--fig:open-loop-shaping).
|
||||
Having obtained \\(G(s)\\) and \\(G\_d(s)\\), we can transform the system shown in [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr) into a classical feedback architecture as shown in [Figure 6](#figure--fig:open-loop-shaping).
|
||||
|
||||
<a id="figure--fig:classical-feedback-test-system"></a>
|
||||
|
||||
{{< figure src="figs/classical_feedback_test_system.png" caption="<span class='figure-number'>Figure 3: </span>Block diagram corresponding to the example system of Figure [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr)" >}}
|
||||
{{< figure src="figs/classical_feedback_test_system.png" caption="<span class='figure-number'>Figure 3: </span>Block diagram corresponding to the example system of [Figure 2](#figure--fig:mech-sys-1dof-inertial-contr)" >}}
|
||||
|
||||
Let's define the system parameters on Matlab.
|
||||
|
||||
@@ -214,20 +206,16 @@ The Bode plots of \\(G(s)\\) and \\(G\_d(s)\\) are shown in Figures [Figure 4](#
|
||||
{{< figure src="figs/bode_plot_example_Gd.png" caption="<span class='figure-number'>Figure 5: </span>Magnitude of the disturbance transfer function \\(G\_d(s)\\)" >}}
|
||||
|
||||
|
||||
## Classical Open Loop Shaping {#classical-open-loop-shaping}
|
||||
## Classical Open Loop Shaping {#sec:open_loop_shaping}
|
||||
|
||||
<span class="org-target" id="org-target--sec-open-loop-shaping"></span>
|
||||
|
||||
After an introduction to classical Loop Shaping in Section , a practical example is given in Section .
|
||||
After an introduction to classical Loop Shaping in Section [Introduction to Loop Shaping](#sec:open_loop_shaping_introduction), a practical example is given in Section [Example of Manual Open Loop Shaping](#sec:loop_shaping_example).
|
||||
Such Loop Shaping is usually performed manually with tools coming from the classical control theory.
|
||||
|
||||
However, the \\(\mathcal{H}\_\infty\\) synthesis can be used to automate the Loop Shaping process.
|
||||
This is presented in Section and applied on the same example in Section .
|
||||
This is presented in Section [\\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis](#sec:h_infinity_open_loop_shaping) and applied on the same example in Section [Example of the \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis](#sec:h_infinity_open_loop_shaping_example).
|
||||
|
||||
|
||||
### Introduction to Loop Shaping {#introduction-to-loop-shaping}
|
||||
|
||||
<span class="org-target" id="org-target--sec-open-loop-shaping-introduction"></span>
|
||||
### Introduction to Loop Shaping {#sec:open_loop_shaping_introduction}
|
||||
|
||||
<div class="definition">
|
||||
|
||||
@@ -237,7 +225,7 @@ This is presented in Section and applied on the same example in Section .
|
||||
|
||||
<div class="definition">
|
||||
|
||||
The **Loop Gain** (or Loop transfer function) \\(L(s)\\) usually refers to as the product of the controller and the plant (see Figure [Figure 6](#figure--fig:open-loop-shaping)):
|
||||
The **Loop Gain** (or Loop transfer function) \\(L(s)\\) usually refers to as the product of the controller and the plant (see [Figure 6](#figure--fig:open-loop-shaping)):
|
||||
|
||||
\begin{equation}
|
||||
L(s) = G(s) \cdot K(s)
|
||||
@@ -263,7 +251,7 @@ It is widely used and generally successful as many characteristics of the closed
|
||||
|
||||
The shaping of the Loop Gain is done manually by combining several leads, lags, notches...
|
||||
This process is very much simplified by the fact that the loop gain \\(L(s)\\) depends **linearly** on \\(K(s)\\) .
|
||||
A typical wanted Loop Shape is shown in Figure [Figure 7](#figure--fig:open-loop-shaping-shape).
|
||||
A typical wanted Loop Shape is shown in [Figure 7](#figure--fig:open-loop-shaping-shape).
|
||||
Another interesting Loop shape called "Bode Step" is described in (<a href="#citeproc_bib_item_3">Lurie et al. 2002</a>).
|
||||
|
||||
<a id="figure--fig:open-loop-shaping-shape"></a>
|
||||
@@ -272,16 +260,14 @@ Another interesting Loop shape called "Bode Step" is described in (<a href="#cit
|
||||
|
||||
The shaping of **closed-loop** transfer functions is obviously not as simple as they don't depend linearly on \\(K(s)\\).
|
||||
But this is were the \\(\mathcal{H}\_\infty\\) Synthesis will be useful!
|
||||
More details on that in Sections and .
|
||||
More details on that in Sections [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification) and [\\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions](#sec:closed-loop-shaping).
|
||||
|
||||
|
||||
### Example of Manual Open Loop Shaping {#example-of-manual-open-loop-shaping}
|
||||
|
||||
<span class="org-target" id="org-target--sec-loop-shaping-example"></span>
|
||||
### Example of Manual Open Loop Shaping {#sec:loop_shaping_example}
|
||||
|
||||
<div class="exampl">
|
||||
|
||||
Let's take our example system described in Section and design a controller using the Open-Loop shaping synthesis approach.
|
||||
Let's take our example system described in Section [Example System](#sec:example_system) and design a controller using the Open-Loop shaping synthesis approach.
|
||||
The specifications are:
|
||||
|
||||
1. **Disturbance rejection**: Highest possible rejection below 1Hz
|
||||
@@ -324,7 +310,7 @@ K = 14e8 * ... % Gain
|
||||
(1 + s/(2*pi*10/sqrt(8)))/(1 + s/(2*pi*10*sqrt(8))); % Lead
|
||||
```
|
||||
|
||||
The bode plot of the Loop Gain is shown in Figure [Figure 8](#figure--fig:loop-gain-manual-afm) and we can verify that we have the wanted stability margins using the `margin` command:
|
||||
The bode plot of the Loop Gain is shown in [Figure 8](#figure--fig:loop-gain-manual-afm) and we can verify that we have the wanted stability margins using the `margin` command:
|
||||
|
||||
```matlab
|
||||
[Gm, Pm, ~, Wc] = margin(G*K);
|
||||
@@ -341,9 +327,7 @@ The bode plot of the Loop Gain is shown in Figure [Figure 8](#figure--fig:loop-g
|
||||
{{< figure src="figs/loop_gain_manual_afm.png" caption="<span class='figure-number'>Figure 8: </span>Bode Plot of the obtained Loop Gain \\(L(s) = G(s) K(s)\\)" >}}
|
||||
|
||||
|
||||
### \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis {#mathcal-h-infty-loop-shaping-synthesis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-open-loop-shaping"></span>
|
||||
### \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis {#sec:h_infinity_open_loop_shaping}
|
||||
|
||||
The synthesis of controllers based on the Loop Shaping method can be automated using the \\(\mathcal{H}\_\infty\\) Synthesis.
|
||||
|
||||
@@ -370,14 +354,12 @@ Therefore, by just providing the wanted loop shape and the plant model, the \\(\
|
||||
Even though we will not go into details and explain how such synthesis is working, an example is provided in the next section.
|
||||
|
||||
|
||||
### Example of the \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis {#example-of-the-mathcal-h-infty-loop-shaping-synthesis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-open-loop-shaping-example"></span>
|
||||
### Example of the \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis {#sec:h_infinity_open_loop_shaping_example}
|
||||
|
||||
To apply the \\(\mathcal{H}\_\infty\\) Loop Shaping Synthesis, the wanted shape of the loop gain should be determined from the specifications.
|
||||
This is summarized in Table [Table 3](#table--tab:open-loop-shaping-specifications).
|
||||
This is summarized in [Table 3](#table--tab:open-loop-shaping-specifications).
|
||||
|
||||
Such shape corresponds to the typical wanted Loop gain Shape shown in Figure [Figure 7](#figure--fig:open-loop-shaping-shape).
|
||||
Such shape corresponds to the typical wanted Loop gain Shape shown in [Figure 7](#figure--fig:open-loop-shaping-shape).
|
||||
|
||||
<a id="table--tab:open-loop-shaping-specifications"></a>
|
||||
<div class="table-caption">
|
||||
@@ -410,7 +392,7 @@ The \\(\mathcal{H}\_\infty\\) open loop shaping synthesis is then performed usin
|
||||
[K, ~, GAM] = loopsyn(G, Lw);
|
||||
```
|
||||
|
||||
The obtained Loop Gain is shown in Figure [Figure 9](#figure--fig:open-loop-shaping-hinf-L) and matches the specified one by a factor \\(\gamma \approx 2\\).
|
||||
The obtained Loop Gain is shown in [Figure 9](#figure--fig:open-loop-shaping-hinf-L) and matches the specified one by a factor \\(\gamma \approx 2\\).
|
||||
|
||||
<a id="figure--fig:open-loop-shaping-hinf-L"></a>
|
||||
|
||||
@@ -424,7 +406,7 @@ This is usually done by breaking down the controller into simple elements such a
|
||||
|
||||
</div>
|
||||
|
||||
Let's briefly analyze the obtained controller which bode plot is shown in Figure [Figure 10](#figure--fig:open-loop-shaping-hinf-K):
|
||||
Let's briefly analyze the obtained controller which bode plot is shown in [Figure 10](#figure--fig:open-loop-shaping-hinf-K):
|
||||
|
||||
- two integrators are used at low frequency to have the wanted low frequency high gain
|
||||
- a lead is added centered with the crossover frequency to increase the phase margin
|
||||
@@ -434,7 +416,7 @@ Let's briefly analyze the obtained controller which bode plot is shown in Figure
|
||||
|
||||
{{< figure src="figs/open_loop_shaping_hinf_K.png" caption="<span class='figure-number'>Figure 10: </span>Obtained controller \\(K\\) using the open-loop \\(\mathcal{H}\_\infty\\) shaping" >}}
|
||||
|
||||
Let's finally compare the obtained stability margins of the \\(\mathcal{H}\_\infty\\) controller and of the manually developed controller in Table [Table 4](#table--tab:open-loop-shaping-compare).
|
||||
Let's finally compare the obtained stability margins of the \\(\mathcal{H}\_\infty\\) controller and of the manually developed controller in [Table 4](#table--tab:open-loop-shaping-compare).
|
||||
|
||||
<a id="table--tab:open-loop-shaping-compare"></a>
|
||||
<div class="table-caption">
|
||||
@@ -449,23 +431,19 @@ Let's finally compare the obtained stability margins of the \\(\mathcal{H}\_\inf
|
||||
| Crossover \\(\approx 10\\) [Hz] | 10.1 | 9.9 |
|
||||
|
||||
|
||||
## A first Step into the \\(\mathcal{H}\_\infty\\) world {#a-first-step-into-the-mathcal-h-infty-world}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-introduction"></span>
|
||||
## A first Step into the \\(\mathcal{H}\_\infty\\) world {#sec:h_infinity_introduction}
|
||||
|
||||
In this section, the \\(\mathcal{H}\_\infty\\) Synthesis method, which is based on the optimization of the \\(\mathcal{H}\_\infty\\) norm of transfer functions, is introduced.
|
||||
|
||||
After the \\(\mathcal{H}\_\infty\\) norm is defined in Section , the \\(\mathcal{H}\_\infty\\) synthesis procedure is described in Section .
|
||||
After the \\(\mathcal{H}\_\infty\\) norm is defined in Section [The \\(\mathcal{H}\_\infty\\) Norm](#sec:h_infinity_norm), the \\(\mathcal{H}\_\infty\\) synthesis procedure is described in Section [\\(\mathcal{H}\_\infty\\) Synthesis](#sec:h_infinity_synthesis) .
|
||||
|
||||
The generalized plant, a very useful tool to describe a control problem, is presented in Section .
|
||||
The \\(\mathcal{H}\_\infty\\) is then applied to this generalized plant in Section .
|
||||
The generalized plant, a very useful tool to describe a control problem, is presented in Section [The Generalized Plant](#sec:generalized_plant).
|
||||
The \\(\mathcal{H}\_\infty\\) is then applied to this generalized plant in Section [The \\(\mathcal{H}\_\infty\\) Synthesis applied on the Generalized plant](#sec:h_infinity_general_synthesis).
|
||||
|
||||
Finally, an example showing how to convert a typical feedback control architecture into a generalized plant is given in Section .
|
||||
Finally, an example showing how to convert a typical feedback control architecture into a generalized plant is given in Section [From a Classical Feedback Architecture to a Generalized Plant](#sec:generalized_plant_derivation).
|
||||
|
||||
|
||||
### The \\(\mathcal{H}\_\infty\\) Norm {#the-mathcal-h-infty-norm}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-norm"></span>
|
||||
### The \\(\mathcal{H}\_\infty\\) Norm {#sec:h_infinity_norm}
|
||||
|
||||
<div class="definition">
|
||||
|
||||
@@ -495,7 +473,7 @@ hinfnorm(G)
|
||||
7.9216e-06
|
||||
```
|
||||
|
||||
We can see in Figure [Figure 11](#figure--fig:hinfinity-norm-siso-bode) that indeed, the \\(\mathcal{H}\_\infty\\) norm of \\(G(s)\\) does corresponds to the peak value of \\(|G(j\omega)|\\).
|
||||
We can see in [Figure 11](#figure--fig:hinfinity-norm-siso-bode) that indeed, the \\(\mathcal{H}\_\infty\\) norm of \\(G(s)\\) does corresponds to the peak value of \\(|G(j\omega)|\\).
|
||||
|
||||
<a id="figure--fig:hinfinity-norm-siso-bode"></a>
|
||||
|
||||
@@ -504,9 +482,7 @@ We can see in Figure [Figure 11](#figure--fig:hinfinity-norm-siso-bode) that ind
|
||||
</div>
|
||||
|
||||
|
||||
### \\(\mathcal{H}\_\infty\\) Synthesis {#mathcal-h-infty-synthesis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-synthesis"></span>
|
||||
### \\(\mathcal{H}\_\infty\\) Synthesis {#sec:h_infinity_synthesis}
|
||||
|
||||
<div class="definition">
|
||||
|
||||
@@ -514,14 +490,14 @@ The \\(\mathcal{H}\_\infty\\) synthesis is a method that uses an **algorithm** (
|
||||
|
||||
</div>
|
||||
|
||||
Why optimizing the \\(\mathcal{H}\_\infty\\) norm of transfer functions is a pertinent choice will become clear when we will translate the typical control specifications into the \\(\mathcal{H}\_\infty\\) norm of transfer functions in Section .
|
||||
Why optimizing the \\(\mathcal{H}\_\infty\\) norm of transfer functions is a pertinent choice will become clear when we will translate the typical control specifications into the \\(\mathcal{H}\_\infty\\) norm of transfer functions in Section [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification).
|
||||
|
||||
<div class="important">
|
||||
|
||||
Then applying the \\(\mathcal{H}\_\infty\\) synthesis to a plant, the engineer work usually consists of the following steps:
|
||||
|
||||
1. Write the problem as standard \\(\mathcal{H}\_\infty\\) problem using the generalized plant (described in the next section)
|
||||
2. Translate the specifications as \\(\mathcal{H}\_\infty\\) norms of transfer functions (Section )
|
||||
2. Translate the specifications as \\(\mathcal{H}\_\infty\\) norms of transfer functions (Section [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification))
|
||||
3. Make the synthesis and analyze the obtained controller
|
||||
|
||||
As the \\(\mathcal{H}\_\infty\\) synthesis usually gives very high order controllers, an additional step that reduces the controller order is sometimes required for practical implementation.
|
||||
@@ -537,23 +513,21 @@ Note that there are many ways to use the \\(\mathcal{H}\_\infty\\) Synthesis:
|
||||
- Signal Based \\(\mathcal{H}\_\infty\\) Synthesis, and many more...
|
||||
|
||||
|
||||
### The Generalized Plant {#the-generalized-plant}
|
||||
|
||||
<span class="org-target" id="org-target--sec-generalized-plant"></span>
|
||||
### The Generalized Plant {#sec:generalized_plant}
|
||||
|
||||
The first step when applying the \\(\mathcal{H}\_\infty\\) synthesis is usually to write the problem as a standard \\(\mathcal{H}\_\infty\\) problem.
|
||||
This consist of deriving the **Generalized Plant** for the current problem.
|
||||
|
||||
The generalized plant, usually noted \\(P(s)\\), is shown in Figure [Figure 12](#figure--fig:general-plant).
|
||||
The generalized plant, usually noted \\(P(s)\\), is shown in [Figure 12](#figure--fig:general-plant).
|
||||
It has two _sets_ of inputs \\([w,\\,u]\\) and two _sets_ of outputs \\([z\\,v]\\) such that:
|
||||
|
||||
\begin{equation}
|
||||
\begin{bmatrix} z \\\ v \end{bmatrix} = P \begin{bmatrix} w \\\ u \end{bmatrix}
|
||||
\end{equation}
|
||||
|
||||
The meaning of these inputs and outputs are summarized in Table [Table 5](#table--tab:notation-general).
|
||||
The meaning of these inputs and outputs are summarized in [Table 5](#table--tab:notation-general).
|
||||
|
||||
A practical example about how to derive the generalized plant for a classical control problem is given in Section .
|
||||
A practical example about how to derive the generalized plant for a classical control problem is given in Section [From a Classical Feedback Architecture to a Generalized Plant](#sec:generalized_plant_derivation).
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -578,9 +552,7 @@ A practical example about how to derive the generalized plant for a classical co
|
||||
</div>
|
||||
|
||||
|
||||
### The \\(\mathcal{H}\_\infty\\) Synthesis applied on the Generalized plant {#the-mathcal-h-infty-synthesis-applied-on-the-generalized-plant}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-general-synthesis"></span>
|
||||
### The \\(\mathcal{H}\_\infty\\) Synthesis applied on the Generalized plant {#sec:h_infinity_general_synthesis}
|
||||
|
||||
Once the generalized plant is obtained, the \\(\mathcal{H}\_\infty\\) synthesis problem can be stated as follows:
|
||||
|
||||
@@ -593,7 +565,7 @@ Find a stabilizing controller \\(K\\) that, using the sensed outputs \\(v\\), ge
|
||||
|
||||
After \\(K\\) is found, the system is _robustified_ by adjusting the response around the unity gain frequency to increase stability margins.
|
||||
|
||||
The obtained controller \\(K\\) and the generalized plant are connected as shown in Figure [Figure 13](#figure--fig:general-control-names).
|
||||
The obtained controller \\(K\\) and the generalized plant are connected as shown in [Figure 13](#figure--fig:general-control-names).
|
||||
|
||||
<a id="figure--fig:general-control-names"></a>
|
||||
|
||||
@@ -614,21 +586,19 @@ where:
|
||||
- `ncont` is the number of control signals (size of \\(u\\))
|
||||
- `K` obtained controller (of size `ncont x nmeas`) that minimizes the \\(\mathcal{H}\_\infty\\) norm from \\(w\\) to \\(z\\).
|
||||
|
||||
Note that the general control configure of Figure [Figure 13](#figure--fig:general-control-names), as its name implies, is quite _general_ and can represent feedback control as well as feedforward control architectures.
|
||||
Note that the general control configure of [Figure 13](#figure--fig:general-control-names), as its name implies, is quite _general_ and can represent feedback control as well as feedforward control architectures.
|
||||
|
||||
|
||||
### From a Classical Feedback Architecture to a Generalized Plant {#from-a-classical-feedback-architecture-to-a-generalized-plant}
|
||||
### From a Classical Feedback Architecture to a Generalized Plant {#sec:generalized_plant_derivation}
|
||||
|
||||
<span class="org-target" id="org-target--sec-generalized-plant-derivation"></span>
|
||||
|
||||
The procedure to convert a typical control architecture as the one shown in Figure [Figure 14](#figure--fig:classical-feedback-tracking) to a generalized Plant is as follows:
|
||||
The procedure to convert a typical control architecture as the one shown in [Figure 14](#figure--fig:classical-feedback-tracking) to a generalized Plant is as follows:
|
||||
|
||||
1. Define signals of the generalized plant: \\(w\\), \\(z\\), \\(u\\) and \\(v\\)
|
||||
2. Remove \\(K\\) and rearrange the inputs and outputs to match the generalized configuration shown in Figure [Figure 12](#figure--fig:general-plant)
|
||||
2. Remove \\(K\\) and rearrange the inputs and outputs to match the generalized configuration shown in [Figure 12](#figure--fig:general-plant)
|
||||
|
||||
<div class="exercice">
|
||||
|
||||
Consider the feedback control architecture shown in Figure [Figure 14](#figure--fig:classical-feedback-tracking).
|
||||
Consider the feedback control architecture shown in [Figure 14](#figure--fig:classical-feedback-tracking).
|
||||
Suppose we want to design \\(K\\) using the general \\(\mathcal{H}\_\infty\\) synthesis, and suppose the signals to be minimized are the control input \\(u\\) and the tracking error \\(\epsilon\\).
|
||||
|
||||
1. Convert the control architecture to a generalized configuration
|
||||
@@ -648,13 +618,13 @@ First, define the signals of the generalized plant:
|
||||
- Controller inputs: this is the signal at the input of the controller: \\(v = \epsilon\\)
|
||||
- Controller outputs: signal generated by the controller: \\(u\\)
|
||||
|
||||
Then, Remove \\(K\\) and rearrange the inputs and outputs as in Figure [Figure 12](#figure--fig:general-plant).
|
||||
Then, Remove \\(K\\) and rearrange the inputs and outputs as in [Figure 12](#figure--fig:general-plant).
|
||||
|
||||
</details>
|
||||
|
||||
<details><summary>Answer</summary>
|
||||
|
||||
The obtained generalized plant shown in Figure [Figure 15](#figure--fig:mixed-sensitivity-ref-tracking).
|
||||
The obtained generalized plant shown in [Figure 15](#figure--fig:mixed-sensitivity-ref-tracking).
|
||||
|
||||
<a id="figure--fig:mixed-sensitivity-ref-tracking"></a>
|
||||
|
||||
@@ -675,40 +645,36 @@ P.OutputName = {'e', 'u', 'v'};
|
||||
</div>
|
||||
|
||||
|
||||
## Modern Interpretation of Control Specifications {#modern-interpretation-of-control-specifications}
|
||||
## Modern Interpretation of Control Specifications {#sec:modern_interpretation_specification}
|
||||
|
||||
<span class="org-target" id="org-target--sec-modern-interpretation-specification"></span>
|
||||
|
||||
As shown in Section , the loop gain \\(L(s) = G(s) K(s)\\) is a useful and easy tool when manually designing controllers.
|
||||
As shown in Section [Classical Open Loop Shaping](#sec:open_loop_shaping), the loop gain \\(L(s) = G(s) K(s)\\) is a useful and easy tool when manually designing controllers.
|
||||
This is mainly due to the fact that \\(L(s)\\) is very easy to shape as it depends _linearly_ on \\(K(s)\\).
|
||||
Moreover, important quantities such as the stability margins and the control bandwidth can be estimated from the shape/phase of \\(L(s)\\).
|
||||
|
||||
However, the loop gain \\(L(s)\\) does **not** directly give the performances of the closed-loop system.
|
||||
As a matter of fact, the behavior of the closed-loop system by the **closed-loop** transfer functions.
|
||||
These are derived of a typical feedback architecture functions in Section .
|
||||
These are derived of a typical feedback architecture functions in Section [Closed Loop Transfer Functions and the Gang of Four](#sec:closed_loop_tf).
|
||||
|
||||
The modern interpretation of control specifications then consists of determining the **required shape of the closed-loop transfer functions** such that the system behavior corresponds to the requirements.
|
||||
Once this is done, the \\(\mathcal{H}\_\infty\\) synthesis can be used to generate a controller that will **shape** the closed-loop transfer function as specified..
|
||||
This method is presented in Section .
|
||||
This method is presented in Section [\\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions](#sec:closed-loop-shaping).
|
||||
|
||||
One of the most important closed-loop transfer function is called the **sensitivity function**.
|
||||
Its link with the closed-loop behavior of the feedback system is studied in Section .
|
||||
Its link with the closed-loop behavior of the feedback system is studied in Section [The Sensitivity Function](#sec:sensitivity_transfer_functions).
|
||||
|
||||
The robustness (stability margins) of the system can also be linked to the shape of the sensitivity function with the use of the **module margin** (Section ).
|
||||
The robustness (stability margins) of the system can also be linked to the shape of the sensitivity function with the use of the **module margin** (Section [Robustness: Module Margin](#sec:module_margin)).
|
||||
|
||||
Links between typical control specifications and shapes of the closed-loop transfer functions are summarized in Section .
|
||||
Links between typical control specifications and shapes of the closed-loop transfer functions are summarized in Section [Summary of typical specification and associated wanted shaping](#sec:other_requirements).
|
||||
|
||||
|
||||
### Closed Loop Transfer Functions and the Gang of Four {#closed-loop-transfer-functions-and-the-gang-of-four}
|
||||
### Closed Loop Transfer Functions and the Gang of Four {#sec:closed_loop_tf}
|
||||
|
||||
<span class="org-target" id="org-target--sec-closed-loop-tf"></span>
|
||||
|
||||
Consider the typical feedback system shown in Figure [Figure 16](#figure--fig:gang-of-four-feedback).
|
||||
Consider the typical feedback system shown in [Figure 16](#figure--fig:gang-of-four-feedback).
|
||||
|
||||
The behavior (performances) of this feedback system is determined by the closed-loop transfer functions from the inputs (\\(r\\), \\(d\\) and \\(n\\)) to the important signals such as \\(\epsilon\\), \\(u\\) and \\(y\\).
|
||||
|
||||
Depending on the specification, different closed-loop transfer functions do matter.
|
||||
These are summarized in Table [Table 6](#table--tab:spec-closed-loop-tf).
|
||||
These are summarized in [Table 6](#table--tab:spec-closed-loop-tf).
|
||||
|
||||
<a id="figure--fig:gang-of-four-feedback"></a>
|
||||
|
||||
@@ -720,18 +686,18 @@ These are summarized in Table [Table 6](#table--tab:spec-closed-loop-tf).
|
||||
Typical Specification and associated closed-loop transfer function
|
||||
</div>
|
||||
|
||||
| **Specification** | **CL Transfer Function** |
|
||||
|--------------------------------|--------------------------------|
|
||||
| Reference Tracking | From \\(r\\) to \\(\epsilon\\) |
|
||||
| Disturbance Rejection | From \\(d\\) to \\(y\\) |
|
||||
| Measurement Noise Filtering | From \\(n\\) to \\(y\\) |
|
||||
| Small Command Amplitude | From \\(n,r,d\\) to \\(u\\) |
|
||||
| Stability | All |
|
||||
| Robustness (stability margins) | Module margin (see Section ) |
|
||||
| **Specification** | **CL Transfer Function** |
|
||||
|--------------------------------|-----------------------------------------------------------------------------|
|
||||
| Reference Tracking | From \\(r\\) to \\(\epsilon\\) |
|
||||
| Disturbance Rejection | From \\(d\\) to \\(y\\) |
|
||||
| Measurement Noise Filtering | From \\(n\\) to \\(y\\) |
|
||||
| Small Command Amplitude | From \\(n,r,d\\) to \\(u\\) |
|
||||
| Stability | All |
|
||||
| Robustness (stability margins) | Module margin (see Section [Robustness: Module Margin](#sec:module_margin)) |
|
||||
|
||||
<div class="exercice">
|
||||
|
||||
For the feedback system in Figure [Figure 16](#figure--fig:gang-of-four-feedback), write the output signals \\([\epsilon, u, y]\\) as a function of the systems \\(K(s), G(s)\\) and the input signals \\([r, d, n]\\).
|
||||
For the feedback system in [Figure 16](#figure--fig:gang-of-four-feedback), write the output signals \\([\epsilon, u, y]\\) as a function of the systems \\(K(s), G(s)\\) and the input signals \\([r, d, n]\\).
|
||||
|
||||
<details><summary>Hint</summary>
|
||||
|
||||
@@ -767,7 +733,7 @@ The following equations should be obtained:
|
||||
|
||||
<div class="important">
|
||||
|
||||
We can see that they are 4 different closed-loop transfer functions describing the behavior of the feedback system in Figure [Figure 16](#figure--fig:gang-of-four-feedback).
|
||||
We can see that they are 4 different closed-loop transfer functions describing the behavior of the feedback system in [Figure 16](#figure--fig:gang-of-four-feedback).
|
||||
These called the **Gang of Four**:
|
||||
|
||||
\begin{align}
|
||||
@@ -786,7 +752,7 @@ More on that in this [short video](https://www.youtube.com/watch?v=b_8v8scghh8).
|
||||
|
||||
</div>
|
||||
|
||||
The behavior of the feedback system in Figure [Figure 16](#figure--fig:gang-of-four-feedback) is fully described by the following set of equations:
|
||||
The behavior of the feedback system in [Figure 16](#figure--fig:gang-of-four-feedback) is fully described by the following set of equations:
|
||||
|
||||
\begin{align}
|
||||
\epsilon &= S r - GS d - GS n \\\\
|
||||
@@ -798,17 +764,15 @@ Thus, for reference tracking, we have to shape the _closed-loop_ transfer functi
|
||||
Similarly, to reduce the effect of measurement noise \\(n\\) on the output \\(y\\), we have to act on the complementary sensitivity function \\(T(s)\\).
|
||||
|
||||
|
||||
### The Sensitivity Function {#the-sensitivity-function}
|
||||
|
||||
<span class="org-target" id="org-target--sec-sensitivity-transfer-functions"></span>
|
||||
### The Sensitivity Function {#sec:sensitivity_transfer_functions}
|
||||
|
||||
The sensitivity function is indisputably the most important closed-loop transfer function of a feedback system.
|
||||
In this section, we will see how the shape of the sensitivity function will impact the performances of the closed-loop system.
|
||||
|
||||
Suppose we have developed a "_reference_" controller \\(K\_r(s)\\) and made three small changes to obtained three controllers \\(K\_1(s)\\), \\(K\_2(s)\\) and \\(K\_3(s)\\).
|
||||
The obtained sensitivity functions for these four controllers are shown in Figure [Figure 17](#figure--fig:sensitivity-shape-effect) and the corresponding step responses are shown in Figure [Figure 18](#figure--fig:sensitivity-shape-effect-step).
|
||||
The obtained sensitivity functions for these four controllers are shown in [Figure 17](#figure--fig:sensitivity-shape-effect) and the corresponding step responses are shown in [Figure 18](#figure--fig:sensitivity-shape-effect-step).
|
||||
|
||||
The comparison of the sensitivity functions shapes and their effect on the step response is summarized in Table [Table 7](#table--tab:compare-sensitivity-shapes).
|
||||
The comparison of the sensitivity functions shapes and their effect on the step response is summarized in [Table 7](#table--tab:compare-sensitivity-shapes).
|
||||
|
||||
<a id="table--tab:compare-sensitivity-shapes"></a>
|
||||
<div class="table-caption">
|
||||
@@ -841,7 +805,7 @@ Closed-Loop Bandwidth
|
||||
|
||||
<div class="important">
|
||||
|
||||
From the simple analysis above, we can draw a first estimation of the wanted shape for the sensitivity function (Figure [Figure 19](#figure--fig:h-infinity-spec-S)):
|
||||
From the simple analysis above, we can draw a first estimation of the wanted shape for the sensitivity function ([Figure 19](#figure--fig:h-infinity-spec-S)):
|
||||
|
||||
- A small magnitude at low frequency to make the static errors small
|
||||
- A wanted minimum closed-loop bandwidth in order to have fast rise time and good rejection of perturbations
|
||||
@@ -856,9 +820,7 @@ From the simple analysis above, we can draw a first estimation of the wanted sha
|
||||
</div>
|
||||
|
||||
|
||||
### Robustness: Module Margin {#robustness-module-margin}
|
||||
|
||||
<span class="org-target" id="org-target--sec-module-margin"></span>
|
||||
### Robustness: Module Margin {#sec:module_margin}
|
||||
|
||||
Let's start this section by an example demonstrating why the phase and gain margins might not be good indicators of robustness.
|
||||
Will follow a discussion about the module margin, a robustness indicator that can be linked to the \\(\mathcal{H}\_\infty\\) norm of \\(S\\) and that will prove to be very useful.
|
||||
@@ -875,13 +837,13 @@ k = 1e7;
|
||||
Gt = 1/k*(s/w0/4 + 1)/(s^2/w0^2 + 2*xi*s/w0 + 1);
|
||||
```
|
||||
|
||||
Let's say we have designed a controller \\(K\_t(s)\\) that gives the loop gain shown in Figure [Figure 20](#figure--fig:phase-gain-margin-model-plant).
|
||||
Let's say we have designed a controller \\(K\_t(s)\\) that gives the loop gain shown in [Figure 20](#figure--fig:phase-gain-margin-model-plant).
|
||||
|
||||
```matlab
|
||||
Kt = 1.2e6*(s + w0)/s;
|
||||
```
|
||||
|
||||
The following characteristics can be determined from the Loop gain in Figure [Figure 20](#figure--fig:phase-gain-margin-model-plant):
|
||||
The following characteristics can be determined from the Loop gain in [Figure 20](#figure--fig:phase-gain-margin-model-plant):
|
||||
|
||||
- Control bandwidth of \\(\approx 10\\, \text{Hz}\\)
|
||||
- Infinite gain margin (the phase of the loop-gain never reaches \\(-180^o\\))
|
||||
@@ -900,7 +862,7 @@ Now let's suppose the controller is implemented in practice, and the "real" plan
|
||||
xi = 0.03;
|
||||
```
|
||||
|
||||
The obtained "real" loop gain is shown in Figure [Figure 21](#figure--fig:phase-gain-margin-real-plant).
|
||||
The obtained "real" loop gain is shown in [Figure 21](#figure--fig:phase-gain-margin-real-plant).
|
||||
At a frequency little bit above 100Hz, the phase of the loop gain reaches -180 degrees while its magnitude is more than one which indicates instability.
|
||||
|
||||
It is confirmed by checking the stability of the closed loop system:
|
||||
@@ -954,7 +916,7 @@ Module Margin
|
||||
|
||||
<div class="exampl">
|
||||
|
||||
A typical Nyquist plot is shown in Figure [Figure 22](#figure--fig:module-margin-example).
|
||||
A typical Nyquist plot is shown in [Figure 22](#figure--fig:module-margin-example).
|
||||
The gain, phase and module margins are graphically shown to have an idea of what they represent.
|
||||
|
||||
<a id="figure--fig:module-margin-example"></a>
|
||||
@@ -963,7 +925,7 @@ The gain, phase and module margins are graphically shown to have an idea of what
|
||||
|
||||
</div>
|
||||
|
||||
As expected from Figure [Figure 22](#figure--fig:module-margin-example), there is a close relationship between the module margin and the gain and phase margins.
|
||||
As expected from [Figure 22](#figure--fig:module-margin-example), there is a close relationship between the module margin and the gain and phase margins.
|
||||
We can indeed show that for a given value of the module margin \\(\Delta M\\), we have:
|
||||
|
||||
\begin{equation}
|
||||
@@ -1015,9 +977,7 @@ To learn more about module/disk margin, you can check out [this](https://www.you
|
||||
</div>
|
||||
|
||||
|
||||
### Summary of typical specification and associated wanted shaping {#summary-of-typical-specification-and-associated-wanted-shaping}
|
||||
|
||||
<span class="org-target" id="org-target--sec-other-requirements"></span>
|
||||
### Summary of typical specification and associated wanted shaping {#sec:other_requirements}
|
||||
|
||||
<a id="table--tab:specification-modern"></a>
|
||||
<div class="table-caption">
|
||||
@@ -1034,9 +994,7 @@ To learn more about module/disk margin, you can check out [this](https://www.you
|
||||
| Robustness | Phase/Gain margins | Module margin: \\(\Vert S\Vert\_\infty\\) small |
|
||||
|
||||
|
||||
## \\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions {#mathcal-h-infty-shaping-of-closed-loop-transfer-functions}
|
||||
|
||||
<span class="org-target" id="org-target--sec-closed-loop-shaping"></span>
|
||||
## \\(\mathcal{H}\_\infty\\) Shaping of closed-loop transfer functions {#sec:closed-loop-shaping}
|
||||
|
||||
In the previous sections, we have seen that the performances of the system depends on the **shape** of the closed-loop transfer function.
|
||||
Therefore, the synthesis problem is to design \\(K(s)\\) such that closed-loop system is stable and such that the closed-loop transfer functions such as \\(S\\), \\(KS\\) and \\(T\\) are shaped as wanted.
|
||||
@@ -1044,22 +1002,20 @@ This is clearly not simple as these closed-loop transfer functions does not depe
|
||||
But don't worry, the \\(\mathcal{H}\_\infty\\) synthesis will do this job for us!
|
||||
|
||||
To do so, **weighting functions** are included in the generalized plant and the \\(\mathcal{H}\_\infty\\) synthesis applied on the **weighted** generalized plant.
|
||||
Such procedure is presented in Section .
|
||||
Such procedure is presented in Section [How to Shape closed-loop transfer function? Using Weighting Functions!](#sec:weighting_functions).
|
||||
|
||||
Some advice on the design of weighting functions are given in Section .
|
||||
Some advice on the design of weighting functions are given in Section [Design of Weighting Functions](#sec:weighting_functions_design).
|
||||
|
||||
An example of the \\(\mathcal{H}\_\infty\\) shaping of the sensitivity function is studied in Section .
|
||||
An example of the \\(\mathcal{H}\_\infty\\) shaping of the sensitivity function is studied in Section [Shaping the Sensitivity Function](#sec:sensitivity_shaping_example).
|
||||
|
||||
Multiple closed-loop transfer functions can be shaped at the same time.
|
||||
Such synthesis is usually called **Mixed-sensitivity Loop Shaping** and is one of the most powerful tool of the robust control theory.
|
||||
Some insight on the use and limitations of such techniques are given in Section .
|
||||
Some insight on the use and limitations of such techniques are given in Section [Shaping multiple closed-loop transfer functions - Limitations](#sec:shaping_multiple_tf).
|
||||
|
||||
|
||||
### How to Shape closed-loop transfer function? Using Weighting Functions! {#how-to-shape-closed-loop-transfer-function-using-weighting-functions}
|
||||
### How to Shape closed-loop transfer function? Using Weighting Functions! {#sec:weighting_functions}
|
||||
|
||||
<span class="org-target" id="org-target--sec-weighting-functions"></span>
|
||||
|
||||
Suppose we apply the \\(\mathcal{H}\_\infty\\) synthesis on the generalized plant \\(P(s)\\) shown in Figure [Figure 23](#figure--fig:loop-shaping-S-without-W).
|
||||
Suppose we apply the \\(\mathcal{H}\_\infty\\) synthesis on the generalized plant \\(P(s)\\) shown in [Figure 23](#figure--fig:loop-shaping-S-without-W).
|
||||
It will generate a controller \\(K(s)\\) such that the \\(\mathcal{H}\_\infty\\) norm of closed-loop transfer function from \\(r\\) to \\(\epsilon\\) is minimized which is equal to the sensitivity function \\(S\\).
|
||||
Therefore, the synthesis objective is to minimize the \\(\mathcal{H}\_\infty\\) norm of the sensitivity function: \\(\\|S\\|\_\infty\\).
|
||||
|
||||
@@ -1072,7 +1028,7 @@ Clearly this does not allow to **shape** the norm of \\(S(j\omega)\\) over all f
|
||||
|
||||
<div class="important">
|
||||
|
||||
The _trick_ is to include a **weighting function** \\(W\_S(s)\\) in the generalized plant as shown in Figure [Figure 24](#figure--fig:loop-shaping-S-with-W).
|
||||
The _trick_ is to include a **weighting function** \\(W\_S(s)\\) in the generalized plant as shown in [Figure 24](#figure--fig:loop-shaping-S-with-W).
|
||||
|
||||
Now, the closed-loop transfer function from \\(w\\) to \\(z\\) is equal to \\(W\_s(s)S(s)\\) and applying the \\(\mathcal{H}\_\infty\\) synthesis to the _weighted_ generalized plant \\(\tilde{P}(s)\\) will generate a controller \\(K(s)\\) such that \\(\\|W\_s(s)S(s)\\|\_\infty\\) is minimized.
|
||||
|
||||
@@ -1100,7 +1056,7 @@ Therefore, the choice of the weighting function \\(W\_s(s)\\) is very important:
|
||||
|
||||
<div class="exercice">
|
||||
|
||||
Using matlab, compute the weighted generalized plant shown in Figure [Figure 25](#figure--fig:first-order-weight) as a function of \\(G(s)\\) and \\(W\_S(s)\\).
|
||||
Using matlab, compute the weighted generalized plant shown in [Figure 25](#figure--fig:first-order-weight) as a function of \\(G(s)\\) and \\(W\_S(s)\\).
|
||||
|
||||
<details><summary>Hint</summary>
|
||||
|
||||
@@ -1133,9 +1089,7 @@ Pw = blkdiag(Ws, 1)*P;
|
||||
</div>
|
||||
|
||||
|
||||
### Design of Weighting Functions {#design-of-weighting-functions}
|
||||
|
||||
<span class="org-target" id="org-target--sec-weighting-functions-design"></span>
|
||||
### Design of Weighting Functions {#sec:weighting_functions_design}
|
||||
|
||||
Weighting function included in the generalized plant must be **proper**, **stable** and **minimum phase** transfer functions.
|
||||
|
||||
@@ -1168,7 +1122,7 @@ with:
|
||||
|
||||
<div class="exampl">
|
||||
|
||||
The Matlab code below produces a weighting function with the following characteristics (Figure [Figure 25](#figure--fig:first-order-weight)):
|
||||
The Matlab code below produces a weighting function with the following characteristics ([Figure 25](#figure--fig:first-order-weight)):
|
||||
|
||||
- Low frequency gain of 100
|
||||
- Gain of 1 at 10Hz
|
||||
@@ -1240,7 +1194,7 @@ W2 = generateWeight('G0', 1e2, 'G1', 1/2, 'Gc', 1, 'wc', 2*pi*10, 'n', 2);
|
||||
W3 = generateWeight('G0', 1e2, 'G1', 1/2, 'Gc', 1, 'wc', 2*pi*10, 'n', 3);
|
||||
```
|
||||
|
||||
The obtained shapes are shown in Figure [Figure 26](#figure--fig:high-order-weight).
|
||||
The obtained shapes are shown in [Figure 26](#figure--fig:high-order-weight).
|
||||
|
||||
<a id="figure--fig:high-order-weight"></a>
|
||||
|
||||
@@ -1249,9 +1203,7 @@ The obtained shapes are shown in Figure [Figure 26](#figure--fig:high-order-weig
|
||||
</div>
|
||||
|
||||
|
||||
### Shaping the Sensitivity Function {#shaping-the-sensitivity-function}
|
||||
|
||||
<span class="org-target" id="org-target--sec-sensitivity-shaping-example"></span>
|
||||
### Shaping the Sensitivity Function {#sec:sensitivity_shaping_example}
|
||||
|
||||
Let's design a controller using the \\(\mathcal{H}\_\infty\\) shaping of the sensitivity function that fulfils the following requirements:
|
||||
|
||||
@@ -1259,7 +1211,7 @@ Let's design a controller using the \\(\mathcal{H}\_\infty\\) shaping of the sen
|
||||
2. Small static errors for step responses
|
||||
3. Robustness: Large module margin \\(\Delta M > 0.5\\) (\\(\Rightarrow \Delta G > 2\\) and \\(\Delta \phi > 29^o\\))
|
||||
|
||||
As usual, the plant used is the one presented in Section .
|
||||
As usual, the plant used is the one presented in Section [Example System](#sec:example_system).
|
||||
|
||||
<div class="exercice">
|
||||
|
||||
@@ -1267,7 +1219,7 @@ Translate the requirements as upper bounds on the Sensitivity function and desig
|
||||
|
||||
<details><summary>Hint</summary>
|
||||
|
||||
The typical wanted upper bound of the sensitivity function is shown in Figure [Figure 27](#figure--fig:h-infinity-spec-S-bis).
|
||||
The typical wanted upper bound of the sensitivity function is shown in [Figure 27](#figure--fig:h-infinity-spec-S-bis).
|
||||
|
||||
More precisely:
|
||||
|
||||
@@ -1353,7 +1305,7 @@ K = hinfsyn(Pw, 1, 1, 'Display', 'on');
|
||||
& \Leftrightarrow |S(j\omega)| < \frac{0.5}{|W\_s(j\omega)|} \quad \forall \omega
|
||||
\end{align\*}
|
||||
|
||||
This is indeed what we can see by comparing \\(|S|\\) and \\(|W\_S|\\) in Figure [Figure 28](#figure--fig:results-sensitivity-hinf).
|
||||
This is indeed what we can see by comparing \\(|S|\\) and \\(|W\_S|\\) in [Figure 28](#figure--fig:results-sensitivity-hinf).
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -1369,16 +1321,14 @@ It just means that at some frequency, one of the closed-loop transfer functions
|
||||
{{< figure src="figs/results_sensitivity_hinf.png" caption="<span class='figure-number'>Figure 28: </span>Weighting function and obtained closed-loop sensitivity" >}}
|
||||
|
||||
|
||||
### Shaping multiple closed-loop transfer functions - Limitations {#shaping-multiple-closed-loop-transfer-functions-limitations}
|
||||
### Shaping multiple closed-loop transfer functions - Limitations {#sec:shaping_multiple_tf}
|
||||
|
||||
<span class="org-target" id="org-target--sec-shaping-multiple-tf"></span>
|
||||
|
||||
As was shown in Section , each of the four main closed-loop transfer functions (called the _gang of four_) will impact different characteristics of the closed-loop system.
|
||||
This is summarized in Table [Table 9](#table--tab:usual-shaping-gang-four).
|
||||
As was shown in Section [Modern Interpretation of Control Specifications](#sec:modern_interpretation_specification), each of the four main closed-loop transfer functions (called the _gang of four_) will impact different characteristics of the closed-loop system.
|
||||
This is summarized in [Table 9](#table--tab:usual-shaping-gang-four).
|
||||
|
||||
Therefore, we might want to shape multiple closed-loop transfer functions at the same time.
|
||||
For instance \\(S\\) could be shape to have good step responses, \\(KS\\) to limit the input usage and \\(T\\) to filter measurement noise.
|
||||
When multiple closed-loop transfer function are shaped at the same time, it is refereed to as **Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control** and is the subject of Section .
|
||||
When multiple closed-loop transfer function are shaped at the same time, it is refereed to as **Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control** and is the subject of Section [Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control - Example](#sec:h_infinity_mixed_sensitivity).
|
||||
|
||||
<a id="table--tab:usual-shaping-gang-four"></a>
|
||||
<div class="table-caption">
|
||||
@@ -1599,7 +1549,7 @@ You can follows this procedure for \\(T\\), \\(KS\\) and \\(GS\\):
|
||||
|
||||
<details><summary>Answer</summary>
|
||||
|
||||
The obtained constrains are shown in Figure [Figure 35](#figure--fig:h-infinity-4-blocs-constrains).
|
||||
The obtained constrains are shown in [Figure 35](#figure--fig:h-infinity-4-blocs-constrains).
|
||||
|
||||
</details>
|
||||
|
||||
@@ -1609,7 +1559,7 @@ Depending on the frequency band, the norms of the closed-loop transfer functions
|
||||
However, in some frequency band, the norms do not depend on the controller and therefore **cannot** be shaped.
|
||||
|
||||
Therefore the weighting functions should only focus on certainty frequency range depending on the transfer function being shaped.
|
||||
These regions are summarized in Figure [Figure 35](#figure--fig:h-infinity-4-blocs-constrains).
|
||||
These regions are summarized in [Figure 35](#figure--fig:h-infinity-4-blocs-constrains).
|
||||
|
||||
<a id="figure--fig:h-infinity-4-blocs-constrains"></a>
|
||||
|
||||
@@ -1629,25 +1579,21 @@ Two approaches can be used to obtain controllers with reasonable order:
|
||||
</div>
|
||||
|
||||
|
||||
## Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control - Example {#mixed-sensitivity-mathcal-h-infty-control-example}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-infinity-mixed-sensitivity"></span>
|
||||
## Mixed-Sensitivity \\(\mathcal{H}\_\infty\\) Control - Example {#sec:h_infinity_mixed_sensitivity}
|
||||
|
||||
Let's now apply the \\(\mathcal{H}\_\infty\\) Shaping control procedure on a practical example.
|
||||
|
||||
In Section the control problem is presented.
|
||||
The design procedure used to apply the \\(\mathcal{H}\_\infty\\) Mixed Sensitivity synthesis is described in Section .
|
||||
In Section [Control Problem](#sec:ex_control_problem) the control problem is presented.
|
||||
The design procedure used to apply the \\(\mathcal{H}\_\infty\\) Mixed Sensitivity synthesis is described in Section [Control Design Procedure](#sec:ex_control_procedure).
|
||||
|
||||
The important step of interpreting the specifications as wanted shape of closed-loop transfer functions is performed in Section .
|
||||
The important step of interpreting the specifications as wanted shape of closed-loop transfer functions is performed in Section [Modern Interpretation of control specifications](#sec:ex_specification_interpretation).
|
||||
|
||||
Finally, the shaping of closed-loop transfer functions is performed in Sections , and .
|
||||
Finally, the shaping of closed-loop transfer functions is performed in Sections [Step 1 - Shaping of \\(S\\)](#sec:ex_shaping_S), [Step 2 - Shaping of \\(GS\\)](#sec:ex_shaping_GS) and [Step 3 - Shaping of \\(T\\)](#sec:ex_shaping_T).
|
||||
|
||||
|
||||
### Control Problem {#control-problem}
|
||||
### Control Problem {#sec:ex_control_problem}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-control-problem"></span>
|
||||
|
||||
Let's consider our usual _test system_ shown in Figure [Figure 36](#figure--fig:ex-test-system).
|
||||
Let's consider our usual _test system_ shown in [Figure 36](#figure--fig:ex-test-system).
|
||||
|
||||
<a id="figure--fig:ex-test-system"></a>
|
||||
|
||||
@@ -1671,9 +1617,7 @@ The considered inputs are:
|
||||
- measurement noise \\(n\\) with a large spectral density at high frequency (increasing starting from 100Hz)
|
||||
|
||||
|
||||
### Control Design Procedure {#control-design-procedure}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-control-procedure"></span>
|
||||
### Control Design Procedure {#sec:ex_control_procedure}
|
||||
|
||||
Here is the general design procedure that will be followed:
|
||||
|
||||
@@ -1683,7 +1627,7 @@ Here is the general design procedure that will be followed:
|
||||
4. Chose the suitable weighted general plant to shape the wanted quantities
|
||||
5. Shape sequentially the chosen closed-loop transfer functions
|
||||
|
||||
Let's first convert the system of Figure [Figure 36](#figure--fig:ex-test-system) into the classical feedback architecture of Figure [Figure 37](#figure--fig:classical-feedback-test-system-bis).
|
||||
Let's first convert the system of [Figure 36](#figure--fig:ex-test-system) into the classical feedback architecture of [Figure 37](#figure--fig:classical-feedback-test-system-bis).
|
||||
|
||||
<a id="figure--fig:classical-feedback-test-system-bis"></a>
|
||||
|
||||
@@ -1703,7 +1647,7 @@ Gd = (c*s + k)/(m*s^2 + c*s + k);
|
||||
```
|
||||
|
||||
We also define the inputs signals that will be used for time domain simulations.
|
||||
They are graphically shown in Figure [Figure 38](#figure--fig:ex-inputs-signals).
|
||||
They are graphically shown in [Figure 38](#figure--fig:ex-inputs-signals).
|
||||
|
||||
```matlab { linenos=true, linenostart=9 }
|
||||
% Time Vector
|
||||
@@ -1729,13 +1673,13 @@ d(t>0.3) = 5e-6;
|
||||
|
||||
{{< figure src="figs/ex_inputs_signals.png" caption="<span class='figure-number'>Figure 38: </span>Time domain inputs signals" >}}
|
||||
|
||||
We also define the generalized plant corresponding to the system and that will be used for time domain simulations (Figure [Figure 39](#figure--fig:ex-general-plant-sim)).
|
||||
We also define the generalized plant corresponding to the system and that will be used for time domain simulations ([Figure 39](#figure--fig:ex-general-plant-sim)).
|
||||
|
||||
<a id="figure--fig:ex-general-plant-sim"></a>
|
||||
|
||||
{{< figure src="figs/ex_general_plant_sim.png" caption="<span class='figure-number'>Figure 39: </span>Generalized plant that will be used for simulations" >}}
|
||||
|
||||
The Generalized plant of Figure [Figure 39](#figure--fig:ex-general-plant-sim) is defined on Matlab as follows:
|
||||
The Generalized plant of [Figure 39](#figure--fig:ex-general-plant-sim) is defined on Matlab as follows:
|
||||
|
||||
```matlab { linenos=true, linenostart=26 }
|
||||
Psim = [0 0 Gd G
|
||||
@@ -1760,9 +1704,7 @@ u = z(:,2); % Input usage [N]
|
||||
```
|
||||
|
||||
|
||||
### Modern Interpretation of control specifications {#modern-interpretation-of-control-specifications}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-specification-interpretation"></span>
|
||||
### Modern Interpretation of control specifications {#sec:ex_specification_interpretation}
|
||||
|
||||
<div class="exercice">
|
||||
|
||||
@@ -1773,16 +1715,16 @@ u = z(:,2); % Input usage [N]
|
||||
|
||||
<details><summary>Hint</summary>
|
||||
|
||||
1. Make use of Table [Table 9](#table--tab:usual-shaping-gang-four)
|
||||
2. Make use of Table [Table 9](#table--tab:usual-shaping-gang-four)
|
||||
3. See Section
|
||||
4. See Section
|
||||
1. Make use of [Table 9](#table--tab:usual-shaping-gang-four)
|
||||
2. Make use of [Table 9](#table--tab:usual-shaping-gang-four)
|
||||
3. See Section [Shaping multiple closed-loop transfer functions - Limitations](#sec:shaping_multiple_tf)
|
||||
4. See Section [Shaping multiple closed-loop transfer functions - Limitations](#sec:shaping_multiple_tf)
|
||||
|
||||
</details>
|
||||
|
||||
</div>
|
||||
|
||||
After converting the control specifications into wanted shape of closed-loop transfer functions, we might come up with the Table [Table 10](#table--tab:ex-specification-shapes).
|
||||
After converting the control specifications into wanted shape of closed-loop transfer functions, we might come up with the [Table 10](#table--tab:ex-specification-shapes).
|
||||
|
||||
In such case, we want to shape \\(S\\), \\(GS\\) and \\(T\\).
|
||||
|
||||
@@ -1799,7 +1741,7 @@ In such case, we want to shape \\(S\\), \\(GS\\) and \\(T\\).
|
||||
| Reject measurement noise | \\(T\\) | Small high frequency (>100Hz) gain |
|
||||
| Robust System | \\(S\\) | Small \\(\Vert S \Vert\_\infty\\) |
|
||||
|
||||
To do so, we use to generalized plant shown in Figure [Figure 40](#figure--fig:ex-general-plant) for the synthesis where the three closed-loop tranfert functions from \\(w\\) to \\([z\_1\\,,z\_2\\,,z\_3]\\) are respectively \\(S\\), \\(GS\\) and \\(T\\).
|
||||
To do so, we use to generalized plant shown in [Figure 40](#figure--fig:ex-general-plant) for the synthesis where the three closed-loop tranfert functions from \\(w\\) to \\([z\_1\\,,z\_2\\,,z\_3]\\) are respectively \\(S\\), \\(GS\\) and \\(T\\).
|
||||
|
||||
This generalized plant is defined on Matlab as follows:
|
||||
|
||||
@@ -1815,7 +1757,7 @@ P = [1 -1
|
||||
{{< figure src="figs/ex_general_plant.png" caption="<span class='figure-number'>Figure 40: </span>Generalized plant chosen for the shaping of \\(S\\), \\(GS\\) \\(T\\)" >}}
|
||||
|
||||
However, to performed the \\(\mathcal{H}\_\infty\\) loop shaping, we have to include **weighting function** to the Generalized plant.
|
||||
We obtain the **weighted generalized plant** in Figure [Figure 41](#figure--fig:ex-general-weighted-plant), and that is computed using Matlab as follows:
|
||||
We obtain the **weighted generalized plant** in [Figure 41](#figure--fig:ex-general-weighted-plant), and that is computed using Matlab as follows:
|
||||
|
||||
```matlab { linenos=true, linenostart=44 }
|
||||
Pw = blkdiag(W1, W2, W3, 1)*P;
|
||||
@@ -1833,14 +1775,12 @@ K = hinfsyn(Pw, 1, 1);
|
||||
|
||||
Now let's shape the three closed-loop transfer functions sequentially:
|
||||
|
||||
- \\(S\\) is shaped in Section
|
||||
- \\(GS\\) is shaped in Section
|
||||
- \\(T\\) is shaped in Section
|
||||
- \\(S\\) is shaped in Section [Step 1 - Shaping of \\(S\\)](#sec:ex_shaping_S)
|
||||
- \\(GS\\) is shaped in Section [Step 2 - Shaping of \\(GS\\)](#sec:ex_shaping_GS)
|
||||
- \\(T\\) is shaped in Section [Step 3 - Shaping of \\(T\\)](#sec:ex_shaping_T)
|
||||
|
||||
|
||||
### Step 1 - Shaping of \\(S\\) {#step-1-shaping-of-s}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-shaping-S"></span>
|
||||
### Step 1 - Shaping of \\(S\\) {#sec:ex_shaping_S}
|
||||
|
||||
Let's first shape the Sensitivity function as it is usually the most important of the _Gang of four_ closed-loop transfer functions.
|
||||
To do so, we have to create a weight \\(W\_1(s)\\) that defines the wanted upper bound on \\(|S(j\omega)|\\):
|
||||
@@ -1865,7 +1805,7 @@ W2 = tf(1e-8);
|
||||
W3 = tf(1e-8);
|
||||
```
|
||||
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis is performed and the obtained closed-loop transfer functions \\(S\\), \\(GS\\), and \\(T\\) and compared with the upper bounds set by the weighting functions in Figure [Figure 42](#figure--fig:ex-results-1).
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis is performed and the obtained closed-loop transfer functions \\(S\\), \\(GS\\), and \\(T\\) and compared with the upper bounds set by the weighting functions in [Figure 42](#figure--fig:ex-results-1).
|
||||
|
||||
```matlab { linenos=true, linenostart=52 }
|
||||
Pw = blkdiag(W1, W2, W3, 1)*P;
|
||||
@@ -1887,19 +1827,19 @@ K1 = hinfsyn(Pw, 1, 1, 'Display', 'on');
|
||||
|
||||
{{< figure src="figs/ex_results_1.png" caption="<span class='figure-number'>Figure 42: </span>Obtained Shape Closed-Loop transfer functions (dashed black lines indicate inverse magnitude of the weighting functions)" >}}
|
||||
|
||||
Time domain simulation is then performed and the obtained output displacement and control inputs are shown in Figure [Figure 43](#figure--fig:ex-time-domain-1).
|
||||
Time domain simulation is then performed and the obtained output displacement and control inputs are shown in [Figure 43](#figure--fig:ex-time-domain-1).
|
||||
|
||||
We can see:
|
||||
|
||||
- we are not able to follow the ramp input. This have to be solved by modifying the weighting function \\(W\_1(s)\\)
|
||||
- we have poor rejection of disturbances. This we be solve by shaping \\(GS\\) in Section
|
||||
- we have quite large effect of the measurement noise. This will be solved by shaping \\(T\\) in Section
|
||||
- we have poor rejection of disturbances. This we be solve by shaping \\(GS\\) in Section [Step 2 - Shaping of \\(GS\\)](#sec:ex_shaping_GS)
|
||||
- we have quite large effect of the measurement noise. This will be solved by shaping \\(T\\) in Section [Step 3 - Shaping of \\(T\\)](#sec:ex_shaping_T)
|
||||
|
||||
<a id="figure--fig:ex-time-domain-1"></a>
|
||||
|
||||
{{< figure src="figs/ex_time_domain_1.png" caption="<span class='figure-number'>Figure 43: </span>Time domain simulation results" >}}
|
||||
|
||||
Remember that in order to follow ramp inputs, the sensitivity function should have a slope of +40dB/dec at low frequency (Table [Table 9](#table--tab:usual-shaping-gang-four)).
|
||||
Remember that in order to follow ramp inputs, the sensitivity function should have a slope of +40dB/dec at low frequency ([Table 9](#table--tab:usual-shaping-gang-four)).
|
||||
|
||||
To do so, let's modify \\(W\_1\\) to impose a slope of +40dB/dec at low frequency.
|
||||
This can simple be done by using a second order weight:
|
||||
@@ -1911,9 +1851,9 @@ W1 = generateWeight('G0', 1e3, ...
|
||||
'n', 2);
|
||||
```
|
||||
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis is performed using the new weights and the obtained closed-loop shaped are shown in figure [Figure 44](#figure--fig:ex-results-1b).
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis is performed using the new weights and the obtained closed-loop shaped are shown in [Figure 44](#figure--fig:ex-results-1b).
|
||||
|
||||
The time domain signals are shown in Figure [Figure 45](#figure--fig:ex-time-domain-1b) and it is confirmed that the ramps are now follows without static errors.
|
||||
The time domain signals are shown in [Figure 45](#figure--fig:ex-time-domain-1b) and it is confirmed that the ramps are now follows without static errors.
|
||||
|
||||
<a id="figure--fig:ex-results-1b"></a>
|
||||
|
||||
@@ -1924,12 +1864,10 @@ The time domain signals are shown in Figure [Figure 45](#figure--fig:ex-time-dom
|
||||
{{< figure src="figs/ex_time_domain_1b.png" caption="<span class='figure-number'>Figure 45: </span>Time domain simulation results" >}}
|
||||
|
||||
|
||||
### Step 2 - Shaping of \\(GS\\) {#step-2-shaping-of-gs}
|
||||
### Step 2 - Shaping of \\(GS\\) {#sec:ex_shaping_GS}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-shaping-GS"></span>
|
||||
|
||||
Looking at Figure [Figure 46](#figure--fig:ex-results-2), it is clear that the rejection of disturbances is not satisfactory.
|
||||
This can also be seen by the large peak of \\(GS\\) in Figure [Figure 44](#figure--fig:ex-results-1b).
|
||||
Looking at [Figure 46](#figure--fig:ex-results-2), it is clear that the rejection of disturbances is not satisfactory.
|
||||
This can also be seen by the large peak of \\(GS\\) in [Figure 44](#figure--fig:ex-results-1b).
|
||||
|
||||
This poor rejection of disturbances is actually due to the fact that the obtain controller has at notch at the resonance frequency of the plant.
|
||||
|
||||
@@ -1940,13 +1878,13 @@ Let's take \\(W\_2\\) as a simple constant gain:
|
||||
W2 = tf(4e5);
|
||||
```
|
||||
|
||||
The \\(\mathcal{H}\_\infty\\) Synthesis is performed and the obtained closed-loop transfer functions are shown in Figure [Figure 46](#figure--fig:ex-results-2).
|
||||
The \\(\mathcal{H}\_\infty\\) Synthesis is performed and the obtained closed-loop transfer functions are shown in [Figure 46](#figure--fig:ex-results-2).
|
||||
|
||||
<a id="figure--fig:ex-results-2"></a>
|
||||
|
||||
{{< figure src="figs/ex_results_2.png" caption="<span class='figure-number'>Figure 46: </span>Obtained Shape Closed-Loop transfer functions" >}}
|
||||
|
||||
Time domain simulation results are shown in Figure [Figure 47](#figure--fig:ex-time-domain-2).
|
||||
Time domain simulation results are shown in [Figure 47](#figure--fig:ex-time-domain-2).
|
||||
If is shown that indeed, the disturbance rejection performance are much better and only very small oscillation is obtained.
|
||||
|
||||
<a id="figure--fig:ex-time-domain-2"></a>
|
||||
@@ -1954,9 +1892,7 @@ If is shown that indeed, the disturbance rejection performance are much better a
|
||||
{{< figure src="figs/ex_time_domain_2.png" caption="<span class='figure-number'>Figure 47: </span>Time domain simulation results" >}}
|
||||
|
||||
|
||||
### Step 3 - Shaping of \\(T\\) {#step-3-shaping-of-t}
|
||||
|
||||
<span class="org-target" id="org-target--sec-ex-shaping-T"></span>
|
||||
### Step 3 - Shaping of \\(T\\) {#sec:ex_shaping_T}
|
||||
|
||||
Finally, we want to limit the effect of the noise on the displacement output.
|
||||
|
||||
@@ -1974,7 +1910,7 @@ W3 = generateWeight('G0', 1e-1, ...
|
||||
```
|
||||
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis is performed and \\(\gamma\\) is closed to one.
|
||||
The obtained closed-loop transfer functions are shown in Figure [Figure 48](#figure--fig:ex-results-3) and we can obverse that:
|
||||
The obtained closed-loop transfer functions are shown in [Figure 48](#figure--fig:ex-results-3) and we can obverse that:
|
||||
|
||||
- The high frequency gain of \\(T\\) is indeed reduced
|
||||
- This comes as the expense of a large magnitude both \\(GS\\) and \\(S\\).
|
||||
@@ -1984,10 +1920,10 @@ The obtained closed-loop transfer functions are shown in Figure [Figure 48](#fig
|
||||
|
||||
{{< figure src="figs/ex_results_3.png" caption="<span class='figure-number'>Figure 48: </span>Obtained Shape Closed-Loop transfer functions" >}}
|
||||
|
||||
The time domain simulation signals are shown in Figure [Figure 49](#figure--fig:ex-time-domain-3).
|
||||
The time domain simulation signals are shown in [Figure 49](#figure--fig:ex-time-domain-3).
|
||||
We can indeed see a slightly less good disturbance rejection.
|
||||
However, the vibrations induced by the sensor noise is well reduced.
|
||||
This can be seen when zooming on the output signal in Figure [Figure 50](#figure--fig:ex-time-domaim-3-zoom).
|
||||
This can be seen when zooming on the output signal in [Figure 50](#figure--fig:ex-time-domaim-3-zoom).
|
||||
|
||||
<a id="figure--fig:ex-time-domain-3"></a>
|
||||
|
||||
@@ -2007,9 +1943,7 @@ As an exercise, plot and analyze the evolution of the controller and loop gain t
|
||||
If the large input usage is considered to be not acceptable, the shaping of \\(KS\\) could be included in the synthesis and all the _Gang of four_ closed-loop transfer function shapes.
|
||||
|
||||
|
||||
## Conclusion {#conclusion}
|
||||
|
||||
<span class="org-target" id="org-target--sec-conclusion"></span>
|
||||
## Conclusion {#sec:conclusion}
|
||||
|
||||
Hopefully, this document gave you a glimpse on how useful and powerful the \\(\mathcal{H}\_\infty\\) loop shaping synthesis can be.
|
||||
One of the true power of \\(\mathcal{H}\_\infty\\) synthesis is that is can easily be applied to multi-input multi-output systems!
|
||||
|
||||
|
After Width: | Height: | Size: 18 KiB |
|
After Width: | Height: | Size: 33 KiB |
|
After Width: | Height: | Size: 34 KiB |
|
After Width: | Height: | Size: 118 KiB |
|
After Width: | Height: | Size: 265 KiB |
|
After Width: | Height: | Size: 118 KiB |
|
After Width: | Height: | Size: 46 KiB |
|
After Width: | Height: | Size: 44 KiB |
|
After Width: | Height: | Size: 43 KiB |
|
After Width: | Height: | Size: 46 KiB |
|
After Width: | Height: | Size: 76 KiB |
|
After Width: | Height: | Size: 28 KiB |
|
After Width: | Height: | Size: 3.1 KiB |
|
After Width: | Height: | Size: 23 KiB |
|
After Width: | Height: | Size: 150 KiB |
|
After Width: | Height: | Size: 157 KiB |
|
After Width: | Height: | Size: 91 KiB |
|
After Width: | Height: | Size: 79 KiB |
|
After Width: | Height: | Size: 44 KiB |
|
After Width: | Height: | Size: 19 KiB |
|
After Width: | Height: | Size: 16 KiB |
|
After Width: | Height: | Size: 59 KiB |
|
After Width: | Height: | Size: 160 KiB |
|
After Width: | Height: | Size: 93 KiB |
|
After Width: | Height: | Size: 92 KiB |
|
After Width: | Height: | Size: 18 KiB |
|
After Width: | Height: | Size: 15 KiB |
|
After Width: | Height: | Size: 13 KiB |
|
After Width: | Height: | Size: 9.0 KiB |
|
After Width: | Height: | Size: 14 KiB |
|
After Width: | Height: | Size: 17 KiB |
|
After Width: | Height: | Size: 15 KiB |
|
After Width: | Height: | Size: 47 KiB |
|
After Width: | Height: | Size: 48 KiB |
|
After Width: | Height: | Size: 45 KiB |
|
After Width: | Height: | Size: 37 KiB |
|
After Width: | Height: | Size: 29 KiB |
@@ -2,3 +2,7 @@
|
||||
title = "Publications"
|
||||
draft = false
|
||||
+++
|
||||
|
||||
**Reproducible research:**
|
||||
I try to apply reproducible-research practices to all my work: the data, scripts and source files behind each publication are made available, so that anyone can regenerate the figures and reproduce the findings.
|
||||
Each entry below links to the paper, and, when available, to the associated code and data.
|
||||
@@ -11,9 +11,9 @@ One use of complementary filter is described below:
|
||||
> The basic idea of a complementary filter involves taking two or more sensors, filtering out unreliable frequencies for each sensor, and combining the filtered outputs to get a better estimate throughout the entire bandwidth of the system.
|
||||
> To achieve this, the sensors included in the filter should complement one another by performing better over specific parts of the system bandwidth.
|
||||
|
||||
- in section , the \\(\mathcal{H}\_\infty\\) synthesis is used for generating two complementary filters
|
||||
- in section , a method using the \\(\mathcal{H}\_\infty\\) synthesis is proposed to shape three of more complementary filters
|
||||
- in section , the \\(\mathcal{H}\_\infty\\) synthesis is used and compared with FIR complementary filters used for LIGO
|
||||
- in section [H-Infinity synthesis of complementary filters](#sec:h_inf_synthesis_complementary_filters), the \\(\mathcal{H}\_\infty\\) synthesis is used for generating two complementary filters
|
||||
- in section [Generating 3 complementary filters](#sec:three_comp_filters), a method using the \\(\mathcal{H}\_\infty\\) synthesis is proposed to shape three of more complementary filters
|
||||
- in section [Try to implement complementary filters for LIGO](#sec:comp_filters_ligo), the \\(\mathcal{H}\_\infty\\) synthesis is used and compared with FIR complementary filters used for LIGO
|
||||
|
||||
<div class="note">
|
||||
|
||||
@@ -22,9 +22,7 @@ Add the Matlab code use to obtain the results presented in the paper are accessi
|
||||
</div>
|
||||
|
||||
|
||||
## H-Infinity synthesis of complementary filters {#h-infinity-synthesis-of-complementary-filters}
|
||||
|
||||
<span class="org-target" id="org-target--sec-h-inf-synthesis-complementary-filters"></span>
|
||||
## H-Infinity synthesis of complementary filters {#sec:h_inf_synthesis_complementary_filters}
|
||||
|
||||
<div class="note">
|
||||
|
||||
@@ -38,13 +36,13 @@ The Matlab file corresponding to this section is accessible [here](https://git.t
|
||||
We here synthesize two complementary filters using the \\(\mathcal{H}\_\infty\\) synthesis.
|
||||
The goal is to specify upper bounds on the norms of the two complementary filters \\(H\_1(s)\\) and \\(H\_2(s)\\) while ensuring their complementary property (\\(H\_1(s) + H\_2(s) = 1\\)).
|
||||
|
||||
In order to do so, we use the generalized plant shown on figure [Figure 1](#figure--fig:h-infinity-robst-fusion) where \\(W\_1(s)\\) and \\(W\_2(s)\\) are weighting transfer functions that will be used to shape \\(H\_1(s)\\) and \\(H\_2(s)\\) respectively.
|
||||
In order to do so, we use the generalized plant shown on [Figure 1](#figure--fig:h-infinity-robst-fusion) where \\(W\_1(s)\\) and \\(W\_2(s)\\) are weighting transfer functions that will be used to shape \\(H\_1(s)\\) and \\(H\_2(s)\\) respectively.
|
||||
|
||||
<a id="figure--fig:h-infinity-robst-fusion"></a>
|
||||
|
||||
{{< figure src="h_infinity_robust_fusion.png" caption="<span class='figure-number'>Figure 1: </span>\\(\mathcal{H}\_\infty\\) synthesis of the complementary filters" >}}
|
||||
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis applied on this generalized plant will give a transfer function \\(H\_2\\) (figure [Figure 1](#figure--fig:h-infinity-robst-fusion)) such that the \\(\mathcal{H}\_\infty\\) norm of the transfer function from \\(w\\) to \\([z\_1,\ z\_2]\\) is less than one:
|
||||
The \\(\mathcal{H}\_\infty\\) synthesis applied on this generalized plant will give a transfer function \\(H\_2\\) ([Figure 1](#figure--fig:h-infinity-robst-fusion)) such that the \\(\mathcal{H}\_\infty\\) norm of the transfer function from \\(w\\) to \\([z\_1,\ z\_2]\\) is less than one:
|
||||
\\[ \left\\| \begin{array}{c} (1 - H\_2(s)) W\_1(s) \\\ H\_2(s) W\_2(s) \end{array} \right\\|\_\infty < 1 \\]
|
||||
|
||||
Thus, if the above condition is verified, we can define \\(H\_1(s) = 1 - H\_2(s)\\) and we have that:
|
||||
@@ -78,7 +76,7 @@ The parameters permits to specify:
|
||||
- the absolute gain at \\(\omega\_0\\): \\(G\_c = |W(j\omega\_0)|\\)
|
||||
- the absolute slope between high and low frequency: \\(n\\)
|
||||
|
||||
The general shape of a weighting function generated using the formula is shown in figure [Figure 2](#figure--fig:weight-formula).
|
||||
The general shape of a weighting function generated using the formula is shown in [Figure 2](#figure--fig:weight-formula).
|
||||
|
||||
<a id="figure--fig:weight-formula"></a>
|
||||
|
||||
@@ -146,7 +144,7 @@ Test bounds: 0.1000 < gamma <= 1050.0000
|
||||
Gamma value achieved: 1.0036
|
||||
```
|
||||
|
||||
We then define the high pass filter \\(H\_1 = 1 - H\_2\\). The bode plot of both \\(H\_1\\) and \\(H\_2\\) is shown on figure [Figure 4](#figure--fig:hinf-filters-results).
|
||||
We then define the high pass filter \\(H\_1 = 1 - H\_2\\). The bode plot of both \\(H\_1\\) and \\(H\_2\\) is shown on [Figure 4](#figure--fig:hinf-filters-results).
|
||||
|
||||
```matlab
|
||||
H1 = 1 - H2;
|
||||
@@ -155,16 +153,14 @@ We then define the high pass filter \\(H\_1 = 1 - H\_2\\). The bode plot of both
|
||||
|
||||
### Obtained Complementary Filters {#obtained-complementary-filters}
|
||||
|
||||
The obtained complementary filters are shown on figure [Figure 4](#figure--fig:hinf-filters-results).
|
||||
The obtained complementary filters are shown on [Figure 4](#figure--fig:hinf-filters-results).
|
||||
|
||||
<a id="figure--fig:hinf-filters-results"></a>
|
||||
|
||||
{{< figure src="figs/hinf_filters_results.png" caption="<span class='figure-number'>Figure 4: </span>Obtained complementary filters using \\(\mathcal{H}\_\infty\\) synthesis" >}}
|
||||
|
||||
|
||||
## Generating 3 complementary filters {#generating-3-complementary-filters}
|
||||
|
||||
<span class="org-target" id="org-target--sec-three-comp-filters"></span>
|
||||
## Generating 3 complementary filters {#sec:three_comp_filters}
|
||||
|
||||
<div class="note">
|
||||
|
||||
@@ -184,7 +180,7 @@ We want:
|
||||
& H\_1(s) + H\_2(s) + H\_3(s) = 1
|
||||
\end{align\*}
|
||||
|
||||
For that, we use the \\(\mathcal{H}\_\infty\\) synthesis with the architecture shown on figure [Figure 5](#figure--fig:comp-filter-three-hinf).
|
||||
For that, we use the \\(\mathcal{H}\_\infty\\) synthesis with the architecture shown on [Figure 5](#figure--fig:comp-filter-three-hinf).
|
||||
|
||||
<a id="figure--fig:comp-filter-three-hinf"></a>
|
||||
|
||||
@@ -286,9 +282,7 @@ The obtained filters are:
|
||||
{{< figure src="figs/three_complementary_filters_results.png" caption="<span class='figure-number'>Figure 7: </span>The three complementary filters obtained after \\(\mathcal{H}\_\infty\\) synthesis" >}}
|
||||
|
||||
|
||||
## Try to implement complementary filters for LIGO {#try-to-implement-complementary-filters-for-ligo}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comp-filters-ligo"></span>
|
||||
## Try to implement complementary filters for LIGO {#sec:comp_filters_ligo}
|
||||
|
||||
<div class="note">
|
||||
|
||||
@@ -310,7 +304,7 @@ The specifications for the filters are:
|
||||
3. Between \\(0.04\text{ Hz}\\) and \\(0.1\text{ Hz}\\), the magnitude of the transfer function should be less than 3
|
||||
4. Above \\(0.1\text{ Hz}\\), the maximum of the magnitude of the complement filter should be as close to zero as possible. In our system, we would like to have the magnitude of the complementary filter to be less than \\(0.1\\). As the filters obtained in (<a href="#citeproc_bib_item_1">Hua 2005</a>) have a magnitude of \\(0.045\\), we will set that as our requirement
|
||||
|
||||
The specifications are translated in upper bounds of the complementary filters are shown on figure [Figure 8](#figure--fig:ligo-specifications).
|
||||
The specifications are translated in upper bounds of the complementary filters are shown on [Figure 8](#figure--fig:ligo-specifications).
|
||||
|
||||
<a id="figure--fig:ligo-specifications"></a>
|
||||
|
||||
@@ -463,7 +457,7 @@ Optimal value (cvx_optval): -0.0433341
|
||||
h = y(2:end);
|
||||
```
|
||||
|
||||
Finally, we compute the filter response over the frequency vector defined and the result is shown on figure [Figure 9](#figure--fig:fir-filter-ligo) which is very close to the filters obtain in (<a href="#citeproc_bib_item_1">Hua 2005</a>).
|
||||
Finally, we compute the filter response over the frequency vector defined and the result is shown on [Figure 9](#figure--fig:fir-filter-ligo) which is very close to the filters obtain in (<a href="#citeproc_bib_item_1">Hua 2005</a>).
|
||||
|
||||
```matlab
|
||||
w = [w1 w2 w3 w4];
|
||||
@@ -485,7 +479,7 @@ Here are the requirements on the filters:
|
||||
- to be as close as possible to the specified upper bounds
|
||||
- stable minimum phase
|
||||
|
||||
The bode plot of the weights is shown on figure [Figure 10](#figure--fig:ligo-weights).
|
||||
The bode plot of the weights is shown on [Figure 10](#figure--fig:ligo-weights).
|
||||
|
||||
<a id="figure--fig:ligo-weights"></a>
|
||||
|
||||
@@ -494,7 +488,7 @@ The bode plot of the weights is shown on figure [Figure 10](#figure--fig:ligo-we
|
||||
|
||||
### H-Infinity Synthesis {#h-infinity-synthesis}
|
||||
|
||||
We define the generalized plant as shown on figure [Figure 1](#figure--fig:h-infinity-robst-fusion).
|
||||
We define the generalized plant as shown on [Figure 1](#figure--fig:h-infinity-robst-fusion).
|
||||
|
||||
```matlab
|
||||
P = [0 wL;
|
||||
@@ -544,7 +538,7 @@ The size of the filters is shown below.
|
||||
State-space model with 1 outputs, 1 inputs, and 27 states.
|
||||
```
|
||||
|
||||
The bode plot of the obtained filters as shown on figure [Figure 11](#figure--fig:hinf-synthesis-ligo-results).
|
||||
The bode plot of the obtained filters as shown on [Figure 11](#figure--fig:hinf-synthesis-ligo-results).
|
||||
|
||||
<a id="figure--fig:hinf-synthesis-ligo-results"></a>
|
||||
|
||||
@@ -553,7 +547,7 @@ The bode plot of the obtained filters as shown on figure [Figure 11](#figure--fi
|
||||
|
||||
### Compare FIR and H-Infinity Filters {#compare-fir-and-h-infinity-filters}
|
||||
|
||||
Let's now compare the FIR filters designed in (<a href="#citeproc_bib_item_1">Hua 2005</a>) and the one obtained with the \\(\mathcal{H}\_\infty\\) synthesis on figure [Figure 12](#figure--fig:comp-fir-ligo-hinf).
|
||||
Let's now compare the FIR filters designed in (<a href="#citeproc_bib_item_1">Hua 2005</a>) and the one obtained with the \\(\mathcal{H}\_\infty\\) synthesis on [Figure 12](#figure--fig:comp-fir-ligo-hinf).
|
||||
|
||||
<a id="figure--fig:comp-fir-ligo-hinf"></a>
|
||||
|
||||
|
||||
@@ -4,20 +4,16 @@ author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
+++
|
||||
|
||||
<hr>
|
||||
<p>This report is also available as a <a href="./index.pdf">pdf</a>.</p>
|
||||
<hr>
|
||||
|
||||
This document gathers the Matlab code used to for the conference paper (<a href="#citeproc_bib_item_1">Dehaeze and Collette 2020</a>) and the journal paper (<a href="#citeproc_bib_item_3">Dehaeze and Collette 2021</a>).
|
||||
|
||||
It is structured in several sections:
|
||||
|
||||
- Section : presents a simple model of a rotating suspended platform that will be used throughout this study.
|
||||
- Section : explains how the unconditional stability of IFF is lost due to Gyroscopic effects induced by the rotation.
|
||||
- Section : suggests a simple modification of the control law such that damping can be added to the suspension modes in a robust way.
|
||||
- Section : proposes to add springs in parallel with the force sensors to regain the unconditional stability of IFF.
|
||||
- Section : compares both proposed modifications to the classical IFF in terms of damping authority and closed-loop system behavior.
|
||||
- Section : contains the notations used for both the Matlab code and the paper
|
||||
- Section [System Description and Analysis](#sec:system_description): presents a simple model of a rotating suspended platform that will be used throughout this study.
|
||||
- Section [Problem with pure Integral Force Feedback](#sec:iff_pure_int): explains how the unconditional stability of IFF is lost due to Gyroscopic effects induced by the rotation.
|
||||
- Section [Integral Force Feedback with an High Pass Filter](#sec:iff_pseudo_int): suggests a simple modification of the control law such that damping can be added to the suspension modes in a robust way.
|
||||
- Section [IFF with a stiffness in parallel with the force sensor](#sec:iff_parallel_stiffness): proposes to add springs in parallel with the force sensors to regain the unconditional stability of IFF.
|
||||
- Section [Comparison](#sec:comparison): compares both proposed modifications to the classical IFF in terms of damping authority and closed-loop system behavior.
|
||||
- Section [Notations](#sec:notations): contains the notations used for both the Matlab code and the paper
|
||||
|
||||
The matlab code is accessible on [Zonodo](https://zenodo.org/record/3894343) and [Github](https://github.com/tdehaeze/dehaeze20_contr_stewa_platf) (<a href="#citeproc_bib_item_2">Dehaeze 2020</a>). It can also be download as a `.zip` file [here](https://git.tdehaeze.xyz/tdehaeze/dehaeze20_activ_dampin_rotat_platf_integ_force_feedb/archive/master.zip).
|
||||
|
||||
@@ -28,23 +24,21 @@ To run the Matlab code, go in the `matlab` directory and run the following Matla
|
||||
Paper's sections and corresponding Matlab files
|
||||
</div>
|
||||
|
||||
| Sections | Matlab File |
|
||||
|----------|----------------------------|
|
||||
| Section | `s1_system_description.m` |
|
||||
| Section | `s2_iff_pure_int.m` |
|
||||
| Section | `s3_iff_hpf.m` |
|
||||
| Section | `s4_iff_kp.m` |
|
||||
| Section | `s5_act_damp_comparison.m` |
|
||||
| Sections | Matlab File |
|
||||
|-----------------------------------------------------------------------------------------------|----------------------------|
|
||||
| Section [System Description and Analysis](#sec:system_description) | `s1_system_description.m` |
|
||||
| Section [Problem with pure Integral Force Feedback](#sec:iff_pure_int) | `s2_iff_pure_int.m` |
|
||||
| Section [Integral Force Feedback with an High Pass Filter](#sec:iff_pseudo_int) | `s3_iff_hpf.m` |
|
||||
| Section [IFF with a stiffness in parallel with the force sensor](#sec:iff_parallel_stiffness) | `s4_iff_kp.m` |
|
||||
| Section [Comparison](#sec:comparison) | `s5_act_damp_comparison.m` |
|
||||
|
||||
|
||||
## System Description and Analysis {#system-description-and-analysis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-system-description"></span>
|
||||
## System Description and Analysis {#sec:system_description}
|
||||
|
||||
|
||||
### System description {#system-description}
|
||||
|
||||
The system consists of one 2 degree of freedom translation stage on top of a spindle (figure [Figure 1](#figure--fig:system)).
|
||||
The system consists of one 2 degree of freedom translation stage on top of a spindle ([Figure 1](#figure--fig:system)).
|
||||
|
||||
<a id="figure--fig:system"></a>
|
||||
|
||||
@@ -56,7 +50,7 @@ As the translation stage is rotating around the Z axis due to the spindle, the f
|
||||
|
||||
### Equations {#equations}
|
||||
|
||||
Based on the Figure [Figure 1](#figure--fig:system), the equations of motions are:
|
||||
Based on the [Figure 1](#figure--fig:system), the equations of motions are:
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -161,7 +155,7 @@ The same transfer function from \\([F\_u, F\_v]\\) to \\([d\_u, d\_v]\\) is writ
|
||||
-2*W*s/(w0^2), (s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2)];
|
||||
```
|
||||
|
||||
Both transfer functions are compared in Figure [Figure 4](#figure--fig:plant-simscape-analytical) and are found to perfectly match.
|
||||
Both transfer functions are compared in [Figure 4](#figure--fig:plant-simscape-analytical) and are found to perfectly match.
|
||||
|
||||
<a id="figure--fig:plant-simscape-analytical"></a>
|
||||
|
||||
@@ -199,11 +193,9 @@ They are compared in Figures [Figure 5](#figure--fig:plant-compare-rotating-spee
|
||||
{{< figure src="figs/plant_compare_rotating_speed_coupling.png" caption="<span class='figure-number'>Figure 6: </span>Comparison of the transfer functions from \\([F\_u, F\_v]\\) to \\([d\_u, d\_v]\\) for several rotating speed - Coupling Terms" >}}
|
||||
|
||||
|
||||
## Problem with pure Integral Force Feedback {#problem-with-pure-integral-force-feedback}
|
||||
## Problem with pure Integral Force Feedback {#sec:iff_pure_int}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-pure-int"></span>
|
||||
|
||||
Force sensors are added in series with the two actuators (Figure [Figure 7](#figure--fig:system-iff)).
|
||||
Force sensors are added in series with the two actuators ([Figure 7](#figure--fig:system-iff)).
|
||||
|
||||
Two identical controllers \\(K\_F\\) are used to feedback each of the sensed force to its associated actuator.
|
||||
|
||||
@@ -311,7 +303,7 @@ The same transfer function from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\\) is writ
|
||||
(2*xi*s/w0 + 1)*2*W*s/(w0^2), (s^2/w0^2 - W^2/w0^2)*((s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2))+ (2*W*s/(w0^2))^2];
|
||||
```
|
||||
|
||||
The two are compared in Figure [Figure 8](#figure--fig:plant-iff-comp-simscape-analytical) and found to perfectly match.
|
||||
The two are compared in [Figure 8](#figure--fig:plant-iff-comp-simscape-analytical) and found to perfectly match.
|
||||
|
||||
<a id="figure--fig:plant-iff-comp-simscape-analytical"></a>
|
||||
|
||||
@@ -338,7 +330,7 @@ The transfer functions from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\\) are identif
|
||||
end
|
||||
```
|
||||
|
||||
The obtained transfer functions are shown in Figure [Figure 9](#figure--fig:plant-iff-compare-rotating-speed).
|
||||
The obtained transfer functions are shown in [Figure 9](#figure--fig:plant-iff-compare-rotating-speed).
|
||||
|
||||
<a id="figure--fig:plant-iff-compare-rotating-speed"></a>
|
||||
|
||||
@@ -356,7 +348,7 @@ The decentralized IFF controller consists of pure integrators:
|
||||
\end{bmatrix}
|
||||
\end{equation}
|
||||
|
||||
The Root Locus (evolution of the poles of the closed loop system in the complex plane as a function of \\(g\\)) is shown in Figure [Figure 10](#figure--fig:root-locus-pure-iff).
|
||||
The Root Locus (evolution of the poles of the closed loop system in the complex plane as a function of \\(g\\)) is shown in [Figure 10](#figure--fig:root-locus-pure-iff).
|
||||
It is shown that for non-null rotating speed, one pole is bound to the right-half plane, and thus the closed loop system is unstable.
|
||||
|
||||
<a id="figure--fig:root-locus-pure-iff"></a>
|
||||
@@ -364,9 +356,7 @@ It is shown that for non-null rotating speed, one pole is bound to the right-hal
|
||||
{{< figure src="figs/root_locus_pure_iff.png" caption="<span class='figure-number'>Figure 10: </span>Root Locus for the Decentralized Integral Force Feedback controller. Several rotating speed are shown." >}}
|
||||
|
||||
|
||||
## Integral Force Feedback with an High Pass Filter {#integral-force-feedback-with-an-high-pass-filter}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-pseudo-int"></span>
|
||||
## Integral Force Feedback with an High Pass Filter {#sec:iff_pseudo_int}
|
||||
|
||||
|
||||
### Plant Parameters {#plant-parameters}
|
||||
@@ -413,7 +403,7 @@ And the following rotating speed.
|
||||
(2*xi*s/w0 + 1)*2*W*s/(w0^2), (s^2/w0^2 - W^2/w0^2)*((s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2))+ (2*W*s/(w0^2))^2];
|
||||
```
|
||||
|
||||
The obtained Loop Gain is shown in Figure [Figure 11](#figure--fig:loop-gain-modified-iff).
|
||||
The obtained Loop Gain is shown in [Figure 11](#figure--fig:loop-gain-modified-iff).
|
||||
|
||||
<a id="figure--fig:loop-gain-modified-iff"></a>
|
||||
|
||||
@@ -422,7 +412,7 @@ The obtained Loop Gain is shown in Figure [Figure 11](#figure--fig:loop-gain-mod
|
||||
|
||||
### Root Locus {#root-locus}
|
||||
|
||||
As shown in the Root Locus plot (Figure [Figure 12](#figure--fig:root-locus-modified-iff)), for some value of the gain, the system remains stable.
|
||||
As shown in the Root Locus plot ([Figure 12](#figure--fig:root-locus-modified-iff)), for some value of the gain, the system remains stable.
|
||||
|
||||
<a id="figure--fig:root-locus-modified-iff"></a>
|
||||
|
||||
@@ -435,7 +425,7 @@ As shown in the Root Locus plot (Figure [Figure 12](#figure--fig:root-locus-modi
|
||||
|
||||
### What is the optimal \\(\omega\_i\\) and \\(g\\)? {#what-is-the-optimal-omega-i-and-g}
|
||||
|
||||
In order to visualize the effect of \\(\omega\_i\\) on the attainable damping, the Root Locus is displayed in Figure [Figure 14](#figure--fig:root-locus-wi-modified-iff) for the following \\(\omega\_i\\):
|
||||
In order to visualize the effect of \\(\omega\_i\\) on the attainable damping, the Root Locus is displayed in [Figure 14](#figure--fig:root-locus-wi-modified-iff) for the following \\(\omega\_i\\):
|
||||
|
||||
```matlab
|
||||
wis = [0.01, 0.1, 0.5, 1]*w0; % [rad/s]
|
||||
@@ -464,10 +454,10 @@ The gain at which the system becomes unstable is
|
||||
g\_\text{max} = \omega\_i \left( \frac{{\omega\_0}^2}{\Omega^2} - 1 \right) \label{eq:iff\_gmax}
|
||||
\end{equation}
|
||||
|
||||
While it seems that small \\(\omega\_i\\) do allow more damping to be added to the system (Figure [Figure 14](#figure--fig:root-locus-wi-modified-iff)), the control gains may be limited to small values due to \ref{eq:iff\_gmax} thus reducing the attainable damping.
|
||||
While it seems that small \\(\omega\_i\\) do allow more damping to be added to the system ([Figure 14](#figure--fig:root-locus-wi-modified-iff)), the control gains may be limited to small values due to \eqref{eq:iff\_gmax} thus reducing the attainable damping.
|
||||
|
||||
There must be an optimum for \\(\omega\_i\\).
|
||||
To find the optimum, the gain that maximize the simultaneous damping of the mode is identified for a wide range of \\(\omega\_i\\) (Figure [Figure 16](#figure--fig:mod-iff-damping-wi)).
|
||||
To find the optimum, the gain that maximize the simultaneous damping of the mode is identified for a wide range of \\(\omega\_i\\) ([Figure 16](#figure--fig:mod-iff-damping-wi)).
|
||||
|
||||
```matlab
|
||||
wis = logspace(-2, 1, 100)*w0; % [rad/s]
|
||||
@@ -492,9 +482,7 @@ To find the optimum, the gain that maximize the simultaneous damping of the mode
|
||||
{{< figure src="figs/mod_iff_damping_wi.png" caption="<span class='figure-number'>Figure 16: </span>Simultaneous attainable damping of the closed loop poles as a function of \\(\omega\_i\\)" >}}
|
||||
|
||||
|
||||
## IFF with a stiffness in parallel with the force sensor {#iff-with-a-stiffness-in-parallel-with-the-force-sensor}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-parallel-stiffness"></span>
|
||||
## IFF with a stiffness in parallel with the force sensor {#sec:iff_parallel_stiffness}
|
||||
|
||||
|
||||
### Schematic {#schematic}
|
||||
@@ -627,7 +615,7 @@ And the IFF plant (transfer function from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\
|
||||
- with a small parallel stiffness \\(k\_p < m \Omega^2\\)
|
||||
- with a large parallel stiffness \\(k\_p > m \Omega^2\\)
|
||||
|
||||
The results are shown in Figure [Figure 19](#figure--fig:plant-iff-kp).
|
||||
The results are shown in [Figure 19](#figure--fig:plant-iff-kp).
|
||||
|
||||
One can see that for \\(k\_p > m \Omega^2\\), the systems shows alternating complex conjugate poles and zeros.
|
||||
|
||||
@@ -673,7 +661,7 @@ One can see that for \\(k\_p > m \Omega^2\\), the systems shows alternating comp
|
||||
|
||||
### IFF when adding a spring in parallel {#iff-when-adding-a-spring-in-parallel}
|
||||
|
||||
In Figure [Figure 20](#figure--fig:root-locus-iff-kp) is displayed the Root Locus in the three considered cases with
|
||||
In [Figure 20](#figure--fig:root-locus-iff-kp) is displayed the Root Locus in the three considered cases with
|
||||
|
||||
\begin{equation}
|
||||
K\_{\text{IFF}} = \frac{g}{s} \begin{bmatrix}
|
||||
@@ -703,7 +691,7 @@ Thus, decentralized IFF controller with pure integrators can be used if:
|
||||
|
||||
However, having large values of \\(k\_p\\) may decrease the attainable damping.
|
||||
|
||||
To study the second point, Root Locus plots for the following values of \\(k\_p\\) are shown in Figure [Figure 22](#figure--fig:root-locus-iff-kps).
|
||||
To study the second point, Root Locus plots for the following values of \\(k\_p\\) are shown in [Figure 22](#figure--fig:root-locus-iff-kps).
|
||||
|
||||
```matlab
|
||||
kps = [2, 20, 40]*m*W^2;
|
||||
@@ -747,9 +735,7 @@ It is shown that large values of \\(k\_p\\) decreases the attainable damping.
|
||||
{{< figure src="figs/opt_damp_alpha.png" caption="<span class='figure-number'>Figure 23: </span>Attainable damping ratio and corresponding controller gain for different parameter \\(\alpha\\)" >}}
|
||||
|
||||
|
||||
## Comparison {#comparison}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comparison"></span>
|
||||
## Comparison {#sec:comparison}
|
||||
|
||||
Two modifications to adapt the IFF control strategy to rotating platforms have been proposed.
|
||||
These two methods are now compared in terms of added damping, closed-loop compliance and transmissibility.
|
||||
@@ -839,9 +825,7 @@ Critical Damping corresponds to to \\(\xi = 1\\), and thus:
|
||||
```
|
||||
|
||||
|
||||
### Transmissibility And Compliance {#transmissibility-and-compliance}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comp-transmissibilty"></span>
|
||||
### Transmissibility And Compliance {#sec:comp_transmissibilty}
|
||||
|
||||
```matlab
|
||||
open('rotating_frame.slx');
|
||||
@@ -929,9 +913,7 @@ Critical Damping corresponds to to \\(\xi = 1\\), and thus:
|
||||
{{< figure src="figs/comp_compliance.png" caption="<span class='figure-number'>Figure 26: </span>Comparison of the obtained Compliance" >}}
|
||||
|
||||
|
||||
## Notations {#notations}
|
||||
|
||||
<span class="org-target" id="org-target--sec-notations"></span>
|
||||
## Notations {#sec:notations}
|
||||
|
||||
| | Mathematical Notation | Matlab | Unit |
|
||||
|---------------------------------------|----------------------------------|---------------|---------|
|
||||
|
||||
|
After Width: | Height: | Size: 79 KiB |
|
After Width: | Height: | Size: 85 KiB |
|
After Width: | Height: | Size: 83 KiB |
@@ -4,20 +4,16 @@ author = ["Dehaeze Thomas"]
|
||||
draft = false
|
||||
+++
|
||||
|
||||
<hr>
|
||||
<p>This report is also available as a <a href="./index.pdf">pdf</a>.</p>
|
||||
<hr>
|
||||
|
||||
This document gathers the Matlab code used to for the conference paper (<a href="#citeproc_bib_item_1">Dehaeze and Collette 2020</a>) and the journal paper (<a href="#citeproc_bib_item_3">Dehaeze and Collette 2021</a>).
|
||||
|
||||
It is structured in several sections:
|
||||
|
||||
- Section : presents a simple model of a rotating suspended platform that will be used throughout this study.
|
||||
- Section : explains how the unconditional stability of IFF is lost due to Gyroscopic effects induced by the rotation.
|
||||
- Section : suggests a simple modification of the control law such that damping can be added to the suspension modes in a robust way.
|
||||
- Section : proposes to add springs in parallel with the force sensors to regain the unconditional stability of IFF.
|
||||
- Section : compares both proposed modifications to the classical IFF in terms of damping authority and closed-loop system behavior.
|
||||
- Section : contains the notations used for both the Matlab code and the paper
|
||||
- Section [System Description and Analysis](#sec:system_description): presents a simple model of a rotating suspended platform that will be used throughout this study.
|
||||
- Section [Problem with pure Integral Force Feedback](#sec:iff_pure_int): explains how the unconditional stability of IFF is lost due to Gyroscopic effects induced by the rotation.
|
||||
- Section [Integral Force Feedback with an High Pass Filter](#sec:iff_pseudo_int): suggests a simple modification of the control law such that damping can be added to the suspension modes in a robust way.
|
||||
- Section [IFF with a stiffness in parallel with the force sensor](#sec:iff_parallel_stiffness): proposes to add springs in parallel with the force sensors to regain the unconditional stability of IFF.
|
||||
- Section [Comparison](#sec:comparison): compares both proposed modifications to the classical IFF in terms of damping authority and closed-loop system behavior.
|
||||
- Section [Notations](#sec:notations): contains the notations used for both the Matlab code and the paper
|
||||
|
||||
The matlab code is accessible on [Zonodo](https://zenodo.org/record/3894343) and [Github](https://github.com/tdehaeze/dehaeze20_contr_stewa_platf) (<a href="#citeproc_bib_item_2">Dehaeze 2020</a>). It can also be download as a `.zip` file [here](https://git.tdehaeze.xyz/tdehaeze/dehaeze21_activ_dampin_rotat_platf_using/archive/master.zip).
|
||||
|
||||
@@ -28,27 +24,25 @@ To run the Matlab code, go in the `matlab` directory and run the following Matla
|
||||
Paper's sections and corresponding Matlab files
|
||||
</div>
|
||||
|
||||
| Sections | Matlab File |
|
||||
|----------|----------------------------|
|
||||
| Section | `s1_system_description.m` |
|
||||
| Section | `s2_iff_pure_int.m` |
|
||||
| Section | `s3_iff_hpf.m` |
|
||||
| Section | `s4_iff_kp.m` |
|
||||
| Section | `s5_act_damp_comparison.m` |
|
||||
| Sections | Matlab File |
|
||||
|-----------------------------------------------------------------------------------------------|----------------------------|
|
||||
| Section [System Description and Analysis](#sec:system_description) | `s1_system_description.m` |
|
||||
| Section [Problem with pure Integral Force Feedback](#sec:iff_pure_int) | `s2_iff_pure_int.m` |
|
||||
| Section [Integral Force Feedback with an High Pass Filter](#sec:iff_pseudo_int) | `s3_iff_hpf.m` |
|
||||
| Section [IFF with a stiffness in parallel with the force sensor](#sec:iff_parallel_stiffness) | `s4_iff_kp.m` |
|
||||
| Section [Comparison](#sec:comparison) | `s5_act_damp_comparison.m` |
|
||||
|
||||
|
||||
## System Description and Analysis {#system-description-and-analysis}
|
||||
|
||||
<span class="org-target" id="org-target--sec-system-description"></span>
|
||||
## System Description and Analysis {#sec:system_description}
|
||||
|
||||
|
||||
### System description {#system-description}
|
||||
|
||||
The system consists of one 2 degree of freedom translation stage on top of a spindle (figure [Figure 1](#figure--fig:system)).
|
||||
The system consists of one 2 degree of freedom translation stage on top of a spindle ([Figure 1](#figure--fig:system)).
|
||||
|
||||
<a id="figure--fig:system"></a>
|
||||
|
||||
{{< figure src="figs-paper/system.png" caption="<span class='figure-number'>Figure 1: </span>Schematic of the studied system" >}}
|
||||
{{< figure src="figs/fig04.png" caption="<span class='figure-number'>Figure 1: </span>Schematic of the studied system" >}}
|
||||
|
||||
The control inputs are the forces applied by the actuators of the translation stage (\\(F\_u\\) and \\(F\_v\\)).
|
||||
As the translation stage is rotating around the Z axis due to the spindle, the forces are applied along \\(\vec{i}\_u\\) and \\(\vec{i}\_v\\).
|
||||
@@ -56,7 +50,7 @@ As the translation stage is rotating around the Z axis due to the spindle, the f
|
||||
|
||||
### Equations {#equations}
|
||||
|
||||
Based on the Figure [Figure 1](#figure--fig:system), the equations of motions are:
|
||||
Based on the [Figure 1](#figure--fig:system), the equations of motions are:
|
||||
|
||||
<div class="important">
|
||||
|
||||
@@ -161,7 +155,7 @@ The same transfer function from \\([F\_u, F\_v]\\) to \\([d\_u, d\_v]\\) is writ
|
||||
-2*W*s/(w0^2), (s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2)];
|
||||
```
|
||||
|
||||
Both transfer functions are compared in Figure [Figure 4](#figure--fig:plant-simscape-analytical) and are found to perfectly match.
|
||||
Both transfer functions are compared in [Figure 4](#figure--fig:plant-simscape-analytical) and are found to perfectly match.
|
||||
|
||||
<a id="figure--fig:plant-simscape-analytical"></a>
|
||||
|
||||
@@ -199,17 +193,15 @@ They are compared in Figures [Figure 5](#figure--fig:plant-compare-rotating-spee
|
||||
{{< figure src="figs/plant_compare_rotating_speed_coupling.png" caption="<span class='figure-number'>Figure 6: </span>Comparison of the transfer functions from \\([F\_u, F\_v]\\) to \\([d\_u, d\_v]\\) for several rotating speed - Coupling Terms" >}}
|
||||
|
||||
|
||||
## Problem with pure Integral Force Feedback {#problem-with-pure-integral-force-feedback}
|
||||
## Problem with pure Integral Force Feedback {#sec:iff_pure_int}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-pure-int"></span>
|
||||
|
||||
Force sensors are added in series with the two actuators (Figure [Figure 7](#figure--fig:system-iff)).
|
||||
Force sensors are added in series with the two actuators ([Figure 7](#figure--fig:system-iff)).
|
||||
|
||||
Two identical controllers \\(K\_F\\) are used to feedback each of the sensed force to its associated actuator.
|
||||
|
||||
<a id="figure--fig:system-iff"></a>
|
||||
|
||||
{{< figure src="figs-paper/system_iff.png" caption="<span class='figure-number'>Figure 7: </span>System with added Force Sensor in series with the actuators" >}}
|
||||
{{< figure src="figs/fig01.png" caption="<span class='figure-number'>Figure 7: </span>System with added Force Sensor in series with the actuators" >}}
|
||||
|
||||
|
||||
### Plant Parameters {#plant-parameters}
|
||||
@@ -311,7 +303,7 @@ The same transfer function from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\\) is writ
|
||||
(2*xi*s/w0 + 1)*2*W*s/(w0^2), (s^2/w0^2 - W^2/w0^2)*((s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2))+ (2*W*s/(w0^2))^2];
|
||||
```
|
||||
|
||||
The two are compared in Figure [Figure 8](#figure--fig:plant-iff-comp-simscape-analytical) and found to perfectly match.
|
||||
The two are compared in [Figure 8](#figure--fig:plant-iff-comp-simscape-analytical) and found to perfectly match.
|
||||
|
||||
<a id="figure--fig:plant-iff-comp-simscape-analytical"></a>
|
||||
|
||||
@@ -338,7 +330,7 @@ The transfer functions from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\\) are identif
|
||||
end
|
||||
```
|
||||
|
||||
The obtained transfer functions are shown in Figure [Figure 9](#figure--fig:plant-iff-compare-rotating-speed).
|
||||
The obtained transfer functions are shown in [Figure 9](#figure--fig:plant-iff-compare-rotating-speed).
|
||||
|
||||
<a id="figure--fig:plant-iff-compare-rotating-speed"></a>
|
||||
|
||||
@@ -356,7 +348,7 @@ The decentralized IFF controller consists of pure integrators:
|
||||
\end{bmatrix}
|
||||
\end{equation}
|
||||
|
||||
The Root Locus (evolution of the poles of the closed loop system in the complex plane as a function of \\(g\\)) is shown in Figure [Figure 10](#figure--fig:root-locus-pure-iff).
|
||||
The Root Locus (evolution of the poles of the closed loop system in the complex plane as a function of \\(g\\)) is shown in [Figure 10](#figure--fig:root-locus-pure-iff).
|
||||
It is shown that for non-null rotating speed, one pole is bound to the right-half plane, and thus the closed loop system is unstable.
|
||||
|
||||
<a id="figure--fig:root-locus-pure-iff"></a>
|
||||
@@ -364,9 +356,7 @@ It is shown that for non-null rotating speed, one pole is bound to the right-hal
|
||||
{{< figure src="figs/root_locus_pure_iff.png" caption="<span class='figure-number'>Figure 10: </span>Root Locus for the Decentralized Integral Force Feedback controller. Several rotating speed are shown." >}}
|
||||
|
||||
|
||||
## Integral Force Feedback with an High Pass Filter {#integral-force-feedback-with-an-high-pass-filter}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-pseudo-int"></span>
|
||||
## Integral Force Feedback with an High Pass Filter {#sec:iff_pseudo_int}
|
||||
|
||||
|
||||
### Plant Parameters {#plant-parameters}
|
||||
@@ -413,7 +403,7 @@ And the following rotating speed.
|
||||
(2*xi*s/w0 + 1)*2*W*s/(w0^2), (s^2/w0^2 - W^2/w0^2)*((s^2)/(w0^2) + 2*xi*s/w0 + 1 - (W^2)/(w0^2))+ (2*W*s/(w0^2))^2];
|
||||
```
|
||||
|
||||
The obtained Loop Gain is shown in Figure [Figure 11](#figure--fig:loop-gain-modified-iff).
|
||||
The obtained Loop Gain is shown in [Figure 11](#figure--fig:loop-gain-modified-iff).
|
||||
|
||||
<a id="figure--fig:loop-gain-modified-iff"></a>
|
||||
|
||||
@@ -422,7 +412,7 @@ The obtained Loop Gain is shown in Figure [Figure 11](#figure--fig:loop-gain-mod
|
||||
|
||||
### Root Locus {#root-locus}
|
||||
|
||||
As shown in the Root Locus plot (Figure [Figure 12](#figure--fig:root-locus-modified-iff)), for some value of the gain, the system remains stable.
|
||||
As shown in the Root Locus plot ([Figure 12](#figure--fig:root-locus-modified-iff)), for some value of the gain, the system remains stable.
|
||||
|
||||
<a id="figure--fig:root-locus-modified-iff"></a>
|
||||
|
||||
@@ -435,7 +425,7 @@ As shown in the Root Locus plot (Figure [Figure 12](#figure--fig:root-locus-modi
|
||||
|
||||
### What is the optimal \\(\omega\_i\\) and \\(g\\)? {#what-is-the-optimal-omega-i-and-g}
|
||||
|
||||
In order to visualize the effect of \\(\omega\_i\\) on the attainable damping, the Root Locus is displayed in Figure [Figure 14](#figure--fig:root-locus-wi-modified-iff) for the following \\(\omega\_i\\):
|
||||
In order to visualize the effect of \\(\omega\_i\\) on the attainable damping, the Root Locus is displayed in [Figure 14](#figure--fig:root-locus-wi-modified-iff) for the following \\(\omega\_i\\):
|
||||
|
||||
```matlab
|
||||
wis = [0.01, 0.1, 0.5, 1]*w0; % [rad/s]
|
||||
@@ -464,10 +454,10 @@ The gain at which the system becomes unstable is
|
||||
g\_\text{max} = \omega\_i \left( \frac{{\omega\_0}^2}{\Omega^2} - 1 \right) \label{eq:iff\_gmax}
|
||||
\end{equation}
|
||||
|
||||
While it seems that small \\(\omega\_i\\) do allow more damping to be added to the system (Figure [Figure 14](#figure--fig:root-locus-wi-modified-iff)), the control gains may be limited to small values due to \ref{eq:iff\_gmax} thus reducing the attainable damping.
|
||||
While it seems that small \\(\omega\_i\\) do allow more damping to be added to the system ([Figure 14](#figure--fig:root-locus-wi-modified-iff)), the control gains may be limited to small values due to \eqref{eq:iff\_gmax} thus reducing the attainable damping.
|
||||
|
||||
There must be an optimum for \\(\omega\_i\\).
|
||||
To find the optimum, the gain that maximize the simultaneous damping of the mode is identified for a wide range of \\(\omega\_i\\) (Figure [Figure 16](#figure--fig:mod-iff-damping-wi)).
|
||||
To find the optimum, the gain that maximize the simultaneous damping of the mode is identified for a wide range of \\(\omega\_i\\) ([Figure 16](#figure--fig:mod-iff-damping-wi)).
|
||||
|
||||
```matlab
|
||||
wis = logspace(-2, 1, 100)*w0; % [rad/s]
|
||||
@@ -492,9 +482,7 @@ To find the optimum, the gain that maximize the simultaneous damping of the mode
|
||||
{{< figure src="figs/mod_iff_damping_wi.png" caption="<span class='figure-number'>Figure 16: </span>Simultaneous attainable damping of the closed loop poles as a function of \\(\omega\_i\\)" >}}
|
||||
|
||||
|
||||
## IFF with a stiffness in parallel with the force sensor {#iff-with-a-stiffness-in-parallel-with-the-force-sensor}
|
||||
|
||||
<span class="org-target" id="org-target--sec-iff-parallel-stiffness"></span>
|
||||
## IFF with a stiffness in parallel with the force sensor {#sec:iff_parallel_stiffness}
|
||||
|
||||
|
||||
### Schematic {#schematic}
|
||||
@@ -503,7 +491,7 @@ In this section additional springs in parallel with the force sensors are added
|
||||
|
||||
<a id="figure--fig:system-parallel-springs"></a>
|
||||
|
||||
{{< figure src="figs-paper/system_parallel_springs.png" caption="<span class='figure-number'>Figure 17: </span>Studied system with additional springs in parallel with the actuators and force sensors" >}}
|
||||
{{< figure src="figs/fig12.png" caption="<span class='figure-number'>Figure 17: </span>Studied system with additional springs in parallel with the actuators and force sensors" >}}
|
||||
|
||||
In order to keep the overall stiffness \\(k = k\_a + k\_p\\) constant, a scalar parameter \\(\alpha\\) (\\(0 \le \alpha < 1\\)) is defined to describe the fraction of the total stiffness in parallel with the actuator and force sensor
|
||||
|
||||
@@ -627,7 +615,7 @@ And the IFF plant (transfer function from \\([F\_u, F\_v]\\) to \\([f\_u, f\_v]\
|
||||
- with a small parallel stiffness \\(k\_p < m \Omega^2\\)
|
||||
- with a large parallel stiffness \\(k\_p > m \Omega^2\\)
|
||||
|
||||
The results are shown in Figure [Figure 19](#figure--fig:plant-iff-kp).
|
||||
The results are shown in [Figure 19](#figure--fig:plant-iff-kp).
|
||||
|
||||
One can see that for \\(k\_p > m \Omega^2\\), the systems shows alternating complex conjugate poles and zeros.
|
||||
|
||||
@@ -673,7 +661,7 @@ One can see that for \\(k\_p > m \Omega^2\\), the systems shows alternating comp
|
||||
|
||||
### IFF when adding a spring in parallel {#iff-when-adding-a-spring-in-parallel}
|
||||
|
||||
In Figure [Figure 20](#figure--fig:root-locus-iff-kp) is displayed the Root Locus in the three considered cases with
|
||||
In [Figure 20](#figure--fig:root-locus-iff-kp) is displayed the Root Locus in the three considered cases with
|
||||
|
||||
\begin{equation}
|
||||
K\_{\text{IFF}} = \frac{g}{s} \begin{bmatrix}
|
||||
@@ -703,7 +691,7 @@ Thus, decentralized IFF controller with pure integrators can be used if:
|
||||
|
||||
However, having large values of \\(k\_p\\) may decrease the attainable damping.
|
||||
|
||||
To study the second point, Root Locus plots for the following values of \\(k\_p\\) are shown in Figure [Figure 22](#figure--fig:root-locus-iff-kps).
|
||||
To study the second point, Root Locus plots for the following values of \\(k\_p\\) are shown in [Figure 22](#figure--fig:root-locus-iff-kps).
|
||||
|
||||
```matlab
|
||||
kps = [2, 20, 40]*m*W^2;
|
||||
@@ -747,9 +735,7 @@ It is shown that large values of \\(k\_p\\) decreases the attainable damping.
|
||||
{{< figure src="figs/opt_damp_alpha.png" caption="<span class='figure-number'>Figure 23: </span>Attainable damping ratio and corresponding controller gain for different parameter \\(\alpha\\)" >}}
|
||||
|
||||
|
||||
## Comparison {#comparison}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comparison"></span>
|
||||
## Comparison {#sec:comparison}
|
||||
|
||||
Two modifications to adapt the IFF control strategy to rotating platforms have been proposed.
|
||||
These two methods are now compared in terms of added damping, closed-loop compliance and transmissibility.
|
||||
@@ -839,9 +825,7 @@ Critical Damping corresponds to to \\(\xi = 1\\), and thus:
|
||||
```
|
||||
|
||||
|
||||
### Transmissibility And Compliance {#transmissibility-and-compliance}
|
||||
|
||||
<span class="org-target" id="org-target--sec-comp-transmissibilty"></span>
|
||||
### Transmissibility And Compliance {#sec:comp_transmissibilty}
|
||||
|
||||
```matlab
|
||||
open('rotating_frame.slx');
|
||||
@@ -929,9 +913,7 @@ Critical Damping corresponds to to \\(\xi = 1\\), and thus:
|
||||
{{< figure src="figs/comp_compliance.png" caption="<span class='figure-number'>Figure 26: </span>Comparison of the obtained Compliance" >}}
|
||||
|
||||
|
||||
## Notations {#notations}
|
||||
|
||||
<span class="org-target" id="org-target--sec-notations"></span>
|
||||
## Notations {#sec:notations}
|
||||
|
||||
| | Mathematical Notation | Matlab | Unit |
|
||||
|---------------------------------------|----------------------------------|---------------|---------|
|
||||
|
||||
@@ -275,89 +275,3 @@ draft = false
|
||||
```
|
||||
|
||||
{{< figure src="mass_spring_damper_hac_lac.png" >}}
|
||||
|
||||
|
||||
## Mass Spring Damper Model - Bis {#mass-spring-damper-model-bis}
|
||||
|
||||
```latex
|
||||
\begin{tikzpicture}
|
||||
% ====================
|
||||
% Parameters
|
||||
% ====================
|
||||
\def\bracs{0.05} % Brace spacing vertically
|
||||
\def\brach{-12pt} % Brace shift horizontaly
|
||||
% ====================
|
||||
|
||||
% ====================
|
||||
% Ground
|
||||
% ====================
|
||||
\draw (-0.9, 0) -- (0.9, 0);
|
||||
\draw[dashed] (0.9, 0) -- ++(0.5, 0);
|
||||
\draw[->] (1.3, 0) -- ++(0, 0.4) node[right]{$w$};
|
||||
% ====================
|
||||
|
||||
% ====================
|
||||
% Granite
|
||||
\begin{scope}[shift={(0, 0)}]
|
||||
\draw[fill=white] (-0.9, 1.2) rectangle (0.9, 2.0) node[pos=0.5]{$\scriptstyle\text{granite}$};
|
||||
\draw[spring] (-0.7, 0) -- ++(0, 1.2);
|
||||
\draw[damper] ( 0, 0) -- ++(0, 1.2);
|
||||
|
||||
\draw[dashed] ( 0.9, 2.0) -- ++(2.0, 0) coordinate(xg);
|
||||
|
||||
% \draw[decorate, decoration={brace, amplitude=8pt}, xshift=\brach] %
|
||||
% (-0.9, \bracs) -- ++(0, 2.0) node[midway,rotate=90,anchor=south,yshift=10pt]{Granite};
|
||||
\end{scope}
|
||||
% ====================
|
||||
|
||||
% ====================
|
||||
% Stages
|
||||
\begin{scope}[shift={(0, 2.0)}]
|
||||
\draw[fill=white] (-0.9, 1.2) rectangle (0.9, 2.0) node[pos=0.5]{$\scriptstyle\mu\text{-station}$};
|
||||
|
||||
\coordinate (mustation) at (0.9, 1.6);
|
||||
|
||||
\draw[spring] (-0.7, 0) -- ++(0, 1.2);
|
||||
\draw[damper] ( 0, 0) -- ++(0, 1.2);
|
||||
\draw[actuator] ( 0.7, 0) -- ++(0, 1.2) node[midway, right=0.1](ft){$f_t$};
|
||||
|
||||
% \draw[decorate, decoration={brace, amplitude=8pt}, xshift=\brach] %
|
||||
% (-0.9, \bracs) -- ++(0, 2.0) node[midway,rotate=90,anchor=south,yshift=10pt]{$\mu\text{-station}$};
|
||||
\end{scope}
|
||||
% ====================
|
||||
|
||||
|
||||
% ====================
|
||||
% NASS
|
||||
\begin{scope}[shift={(0, 4.0)}]
|
||||
\draw[fill=white] (-0.9, 1.2) rectangle (0.9, 2.0) node[pos=0.5]{$\scriptstyle\nu\text{-hexapod}$};
|
||||
\draw[dashed] (0.9, 2.0) -- ++(2.0, 0) coordinate(xnpos);
|
||||
|
||||
\draw[spring] (-0.7, 0) -- ++(0, 1.2) node[midway, left=0.1]{};
|
||||
\draw[damper] ( 0, 0) -- ++(0, 1.2) node[midway, left=0.2]{};
|
||||
\draw[actuator] ( 0.7, 0) -- ++(0, 1.2) coordinate[midway, right=0.1](f);
|
||||
|
||||
% \draw[decorate, decoration={brace, amplitude=8pt}, xshift=\brach] %
|
||||
% (-0.9, \bracs) -- ++(0, 2.2) node[midway,rotate=90,anchor=south,yshift=10pt]{$\nu\text{-hexapod}$};
|
||||
\end{scope}
|
||||
% ====================
|
||||
|
||||
% ====================
|
||||
% Measured Displacement
|
||||
\draw[<->, dashed] ($(xg)+(-0.1, 0)$) node[above left](d){$d$} -- ($(xnpos)+(-0.1, 0)$);
|
||||
% ====================
|
||||
|
||||
% ====================
|
||||
% IFF Control
|
||||
% \node[block={2em}{1.5em}, right=0.6 of fsensn] (iff) {$K_{\scriptscriptstyle IFF}$};
|
||||
% \node[addb] (ctrladd) at (f-|iff) {};
|
||||
\node[block={2em}{1.5em}, right=0.6 of mustation] (ctrl) {$K$};
|
||||
|
||||
% \draw[->] (fsensn.east) -- node[midway, above]{$\tau_m$} (iff.west);
|
||||
% \draw[->] (iff.south) -- (ctrladd.north);
|
||||
% \draw[->] (ctrladd.west) -- (f.east) node[above right]{$u$};
|
||||
\draw[->] (d.west) -| (ctrl.south);
|
||||
\draw[->] (ctrl.north) |- (f) node[above right]{$u$};
|
||||
% ====================
|
||||
\end{tikzpicture}
|
||||
```
|
||||
@@ -1,8 +1,11 @@
|
||||
+++
|
||||
title = "Zettels"
|
||||
title = "Notes"
|
||||
author = ["Thomas Dehaeze"]
|
||||
type = "zettels"
|
||||
url = "/notes/"
|
||||
draft = false
|
||||
+++
|
||||
|
||||
Here is the list of subjects I took note about.
|
||||
Technical notes on control, mechatronics, instrumentation and related topics.
|
||||
This is a living personal wiki, so some notes are still incomplete.
|
||||
Further down, there is a list of notes on books, theses and articles I have read and found interesting.
|
||||
@@ -33,7 +33,7 @@ Let's suppose that the ADC is ideal and the only noise comes from the quantizati
|
||||
Interestingly, the noise amplitude is uniformly distributed.
|
||||
|
||||
The quantization noise can take a value between \\(\pm q/2\\), and the probability density function is constant in this range (i.e., it’s a uniform distribution).
|
||||
Since the integral of the probability density function is equal to one, its value will be \\(1/q\\) for \\(-q/2 < e < q/2\\) (Fig. [Figure 1](#figure--fig:probability-density-function-adc)).
|
||||
Since the integral of the probability density function is equal to one, its value will be \\(1/q\\) for \\(-q/2 < e < q/2\\) ([Figure 1](#figure--fig:probability-density-function-adc)).
|
||||
|
||||
<a id="figure--fig:probability-density-function-adc"></a>
|
||||
|
||||
|
||||
@@ -192,7 +192,7 @@ Characteristics:
|
||||
|
||||
- Zero at \\(\omega\_c/\sqrt{a}\\) and pole at \\(\omega\_c \sqrt{a}\\), geometrically centered on \\(\omega\_c\\)
|
||||
- Unity gain at \\(\omega\_c\\), low frequency gain of \\(1/\sqrt{a}\\), high frequency gain of \\(\sqrt{a}\\)
|
||||
- Maximum phase lead, obtained at \\(\omega\_c\\), equal to (Figure [Figure 8](#figure--fig:filter-lead-effect-a-phase)):
|
||||
- Maximum phase lead, obtained at \\(\omega\_c\\), equal to ([Figure 8](#figure--fig:filter-lead-effect-a-phase)):
|
||||
\\[ \angle H(j\omega\_c) = \tan^{-1}(\sqrt{a}) - \tan^{-1}(1/\sqrt{a}) \\]
|
||||
|
||||
<!--listend-->
|
||||
|
||||
@@ -69,7 +69,7 @@ where \\(F\\) is the ratio of single-stage low pass filter's transition region w
|
||||
F = \frac{f\_{\text{stop}} - B^\prime}{f\_{\text{stop}}}
|
||||
\end{equation}
|
||||
|
||||
After using Eq. \ref{eq:M1opt} to determine the optimum first downsampling factor, and setting \\(M\_1\\) equal to the integer sub-multiple of \\(M\\) that is closest to \\(M\_{1,\text{opt}}\\), the second downsampling factor is:
|
||||
After using Eq. \eqref{eq:M1opt} to determine the optimum first downsampling factor, and setting \\(M\_1\\) equal to the integer sub-multiple of \\(M\\) that is closest to \\(M\_{1,\text{opt}}\\), the second downsampling factor is:
|
||||
|
||||
\begin{equation} \label{eq:M2\_from\_M1}
|
||||
M\_2 = \frac{M}{M\_1}
|
||||
@@ -89,9 +89,9 @@ N = \frac{\text{Atten}}{22 (f\_{\text{stop}} - f\_{\text{pass}})} = \frac{60}{22
|
||||
which is way too large for practical implementation.
|
||||
|
||||
To reduce the number of necessary filter taps, we can partition the decimation problem into two stages.
|
||||
With \\(M = 100\\), \\(F = (2200-1800)/2200\\), Eq. \ref{eq:M1opt} yields \\(M\_{1,\text{opt}} = 26.4\\).
|
||||
With \\(M = 100\\), \\(F = (2200-1800)/2200\\), Eq. \eqref{eq:M1opt} yields \\(M\_{1,\text{opt}} = 26.4\\).
|
||||
The integer sub-multiple of 100 closest to \\(26.4\\) is \\(25\\), so we set \\(M\_1 = 25\\).
|
||||
Next, from Eq. \ref{eq:M2\_from\_M1}, \\(M\_2 = 4\\) is found.
|
||||
Next, from Eq. \eqref{eq:M2\_from\_M1}, \\(M\_2 = 4\\) is found.
|
||||
|
||||
The first low pass filter has a pass-band cutoff frequency of \\(1.8\\,kHz\\) and its stop-band is \\(400/25 - 1.8 = 14.2\\,kHz\\) ([Figure 4](#figure--fig:decimation-two-stage-example) (d)).
|
||||
The second low pass filter has a pass-band cutoff frequency of \\(1.8\\,kHz\\) and its stop-band is \\(4-1.8 = 2.2\\,kHz\\).
|
||||
@@ -116,16 +116,18 @@ There are two **practical issues** to consider for two-stage decimation:
|
||||
|
||||
In order to cope with the second issue, an efficient decimation filter implementation scheme called _polyphase decomposition_ can be used.
|
||||
|
||||
<summary>The advantages of two stage decimation, over single-stage decimation are:
|
||||
<div class="sum">
|
||||
|
||||
<ul class="org-ul">
|
||||
<li>an overall reduction in computation workload</li>
|
||||
<li>reduced signal and filter coefficient data storage</li>
|
||||
<li>simpler filter designs</li>
|
||||
<li>a decrease in the ill effects of finite binary-work-length filter coefficients</li>
|
||||
</ul>
|
||||
The advantages of two stage decimation, over single-stage decimation are:
|
||||
|
||||
These advantages become more pronounced as the overall desired decimation factor \(M\) becomes larger.</summary>
|
||||
- an overall reduction in computation workload
|
||||
- reduced signal and filter coefficient data storage
|
||||
- simpler filter designs
|
||||
- a decrease in the ill effects of finite binary-work-length filter coefficients
|
||||
|
||||
These advantages become more pronounced as the overall desired decimation factor \\(M\\) becomes larger.
|
||||
|
||||
</div>
|
||||
|
||||
|
||||
### References: {#references}
|
||||
|
||||
@@ -36,7 +36,7 @@ It is equal to the inverse of the mass matrix (diagonal when evaluated at the Co
|
||||
\bm{G}\_{\\{CoM\\}}(s) = \frac{\bm{\mathcal{X}}\_{\\{CoM\\}}}{\bm{\mathcal{F}}\_{\\{CoM\\}}} \approx \frac{1}{s^2} \bm{M}^{-1}
|
||||
\end{equation}
|
||||
|
||||
To work at the CoM, the plant is pre- and post-multiplied by the Jacobian matrices as shown in Figure [Figure 1](#figure--fig:detail-control-decoupling-control-jacobian):
|
||||
To work at the CoM, the plant is pre- and post-multiplied by the Jacobian matrices as shown in [Figure 1](#figure--fig:detail-control-decoupling-control-jacobian):
|
||||
|
||||
\begin{equation}
|
||||
\bm{G}\_{\\{CoM\\}}(s) = \bm{J}\_{\\{CoM\\}}^{-1} \\, \bm{G}\_{\\{\mathcal{L}\\}}(s) \\, \bm{J}\_{\\{CoM\\}}^{-\intercal}
|
||||
|
||||
@@ -40,7 +40,7 @@ with:
|
||||
\\(C\_0 = 1\\) corresponds to a conductor with conductivity \\(\sigma\\) inside a uniform magnetic field and conductivity infinite outside this field.
|
||||
A typical value of \\(C\_0\\) is about 0.25-0.4 for a conductor plate with area 2 to 5 times that of the magnetic field.
|
||||
|
||||
From \ref{eq:damping\_formula}, we see that the damping coefficient is proportional to:
|
||||
From \eqref{eq:damping\_formula}, we see that the damping coefficient is proportional to:
|
||||
|
||||
- the square of the magnetic flux density \\(B\\). Therefore it is very important to have large magnetic field strengh
|
||||
- the thickness \\(t\\) of the conductor. However due to **skin depth effect**, the benefit of increasing the thickness is limited.
|
||||
|
||||