Add source code reference
This commit is contained in:
		@@ -566,6 +566,8 @@ While having very different implementations, both proposed modifications are ver
 | 
			
		||||
 | 
			
		||||
Future work will focus on the experimental validation of the proposed active damping techniques.
 | 
			
		||||
 | 
			
		||||
The Matlab code that was used for this study is available under a MIT License and archived in Zenodo cite:dehaeze20_activ_dampin_rotat_posit_platf.
 | 
			
		||||
 | 
			
		||||
* Acknowledgment
 | 
			
		||||
:PROPERTIES:
 | 
			
		||||
:UNNUMBERED: t
 | 
			
		||||
 
 | 
			
		||||
							
								
								
									
										
											BIN
										
									
								
								paper/paper.pdf
									
									
									
									
									
								
							
							
						
						
									
										
											BIN
										
									
								
								paper/paper.pdf
									
									
									
									
									
								
							
										
											Binary file not shown.
										
									
								
							@@ -1,4 +1,4 @@
 | 
			
		||||
% Created 2020-07-08 mer. 18:02
 | 
			
		||||
% Created 2020-07-08 mer. 18:07
 | 
			
		||||
% Intended LaTeX compiler: pdflatex
 | 
			
		||||
\documentclass{ISMA_USD2020}
 | 
			
		||||
\usepackage[utf8]{inputenc}
 | 
			
		||||
@@ -58,7 +58,7 @@ The results reveal that, despite their different implementations, both modified
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
\section{Introduction}
 | 
			
		||||
\label{sec:org639dbba}
 | 
			
		||||
\label{sec:orgc580a8f}
 | 
			
		||||
\label{sec:introduction}
 | 
			
		||||
There is an increasing need to reduce the undesirable vibration of many sensitive equipment.
 | 
			
		||||
A common method to reduce vibration is to mount the sensitive equipment on a suspended platform which attenuates the vibrations above the frequency of the suspension modes.
 | 
			
		||||
@@ -78,7 +78,7 @@ Section \ref{sec:iff_kp} proposes to add springs in parallel with the force sens
 | 
			
		||||
Section \ref{sec:comparison} compares both proposed modifications to the classical IFF in terms of damping authority and closed-loop system behavior.
 | 
			
		||||
 | 
			
		||||
\section{Dynamics of Rotating Platforms}
 | 
			
		||||
\label{sec:orgea844f7}
 | 
			
		||||
\label{sec:orgf7cef1f}
 | 
			
		||||
\label{sec:dynamics}
 | 
			
		||||
In order to study how the rotation does affect the use of IFF, a model of a suspended platform on top of a rotating stage is used.
 | 
			
		||||
Figure \ref{fig:system} represents the model schematically which is the simplest in which gyroscopic forces can be studied.
 | 
			
		||||
@@ -225,7 +225,7 @@ For \(\Omega > \omega_0\), the low frequency pair of complex conjugate poles \(p
 | 
			
		||||
\end{figure}
 | 
			
		||||
 | 
			
		||||
\section{Decentralized Integral Force Feedback}
 | 
			
		||||
\label{sec:org7bfaed6}
 | 
			
		||||
\label{sec:orgcb8c9c7}
 | 
			
		||||
\label{sec:iff}
 | 
			
		||||
In order to apply IFF to the system, force sensors are added in series with the two actuators (Figure \ref{fig:system_iff}).
 | 
			
		||||
As this study focuses on decentralized control, two identical controllers \(K_F\) are used to feedback each of the sensed force to its associated actuator and no attempt is made to counteract the interactions in the system.
 | 
			
		||||
@@ -322,7 +322,7 @@ In order to apply Decentralized IFF on rotating platforms, two solutions are pro
 | 
			
		||||
The first one consists of slightly modifying the control law (Section \ref{sec:iff_hpf}) while the second one consists of adding springs in parallel with the force sensors (Section \ref{sec:iff_kp}).
 | 
			
		||||
 | 
			
		||||
\section{Integral Force Feedback with High Pass Filter}
 | 
			
		||||
\label{sec:org380bd8d}
 | 
			
		||||
\label{sec:org0b913ec}
 | 
			
		||||
\label{sec:iff_hpf}
 | 
			
		||||
As was explained in the previous section, the instability comes in part from the high gain at low frequency caused by the pure integrators.
 | 
			
		||||
 | 
			
		||||
@@ -393,7 +393,7 @@ Three regions can be observed:
 | 
			
		||||
\end{itemize}
 | 
			
		||||
 | 
			
		||||
\section{Integral Force Feedback with Parallel Springs}
 | 
			
		||||
\label{sec:org93348b6}
 | 
			
		||||
\label{sec:org082b3c2}
 | 
			
		||||
\label{sec:iff_kp}
 | 
			
		||||
In this section additional springs in parallel with the force sensors are added to counteract the negative stiffness induced by the rotation.
 | 
			
		||||
Such springs are schematically shown in Figure \ref{fig:system_parallel_springs} where \(k_a\) is the stiffness of the actuator and \(k_p\) the stiffness in parallel with the actuator and force sensor.
 | 
			
		||||
@@ -494,7 +494,7 @@ This is confirmed in Figure \ref{fig:mod_iff_damping_kp} where the attainable cl
 | 
			
		||||
\end{minipage}
 | 
			
		||||
 | 
			
		||||
\section{Comparison and Discussion}
 | 
			
		||||
\label{sec:org5f56e74}
 | 
			
		||||
\label{sec:org1f46ad4}
 | 
			
		||||
\label{sec:comparison}
 | 
			
		||||
Two modifications to adapt the IFF control strategy to rotating platforms have been proposed in Sections \ref{sec:iff_hpf} and \ref{sec:iff_kp}.
 | 
			
		||||
These two methods are now compared in terms of added damping, closed-loop compliance and transmissibility.
 | 
			
		||||
@@ -554,7 +554,7 @@ On can see in Figure \ref{fig:comp_transmissibility} that the problem of the deg
 | 
			
		||||
The addition of the HPF or the use of the parallel stiffness permit to limit the degradation of the compliance as compared with classical IFF (Figure \ref{fig:comp_compliance}).
 | 
			
		||||
 | 
			
		||||
\section{Conclusion}
 | 
			
		||||
\label{sec:org6ee721e}
 | 
			
		||||
\label{sec:org071db57}
 | 
			
		||||
\label{sec:conclusion}
 | 
			
		||||
 | 
			
		||||
Due to gyroscopic effects, decentralized IFF with pure integrators was shown not to be stable when applied to rotating platforms.
 | 
			
		||||
@@ -572,8 +572,10 @@ While having very different implementations, both proposed modifications are ver
 | 
			
		||||
 | 
			
		||||
Future work will focus on the experimental validation of the proposed active damping techniques.
 | 
			
		||||
 | 
			
		||||
The Matlab code that was used for this study is available under a MIT License and archived in Zenodo \cite{dehaeze20_activ_dampin_rotat_posit_platf}.
 | 
			
		||||
 | 
			
		||||
\section*{Acknowledgment}
 | 
			
		||||
\label{sec:orgd2f72ff}
 | 
			
		||||
\label{sec:orgd8daf24}
 | 
			
		||||
This research benefited from a FRIA grant from the French Community of Belgium.
 | 
			
		||||
 | 
			
		||||
\bibliography{ref.bib}
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	