120 lines
5.8 KiB
HTML
120 lines
5.8 KiB
HTML
<?xml version="1.0" encoding="utf-8"?>
|
||
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN"
|
||
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
|
||
<html xmlns="http://www.w3.org/1999/xhtml" lang="en" xml:lang="en">
|
||
<head>
|
||
<!-- 2020-12-07 lun. 11:43 -->
|
||
<meta http-equiv="Content-Type" content="text/html;charset=utf-8" />
|
||
<title>Sample Stabilization for Tomography Experiments in Presence of Large Plant Uncertainty</title>
|
||
<meta name="generator" content="Org mode" />
|
||
<meta name="author" content="Thomas Dehaeze" />
|
||
<link rel="stylesheet" type="text/css" href="https://research.tdehaeze.xyz/css/style.css"/>
|
||
<script type="text/javascript" src="https://research.tdehaeze.xyz/js/script.js"></script>
|
||
<style> #content {margin: auto;} </style>
|
||
</head>
|
||
<body>
|
||
<div id="org-div-home-and-up">
|
||
<a accesskey="h" href="../index.html"> UP </a>
|
||
|
|
||
<a accesskey="H" href="../index.html"> HOME </a>
|
||
</div><div id="content">
|
||
<h1 class="title">Sample Stabilization for Tomography Experiments in Presence of Large Plant Uncertainty
|
||
<br />
|
||
<span class="subtitle">Dehaeze Thomas, Magnin-Mattenet Muriel and Collette Christophe</span>
|
||
</h1>
|
||
<blockquote>
|
||
<p>
|
||
<b>Abstract</b>:
|
||
</p>
|
||
|
||
<p>
|
||
A new low emittance lattice storage ring is under construction at the ESRF.
|
||
In this new instrument, an upgraded end station for ID31 beamline must allow to position the samples along complex trajectories with a nanometer precision.
|
||
In order to reach these requirements, samples have to be mounted on high precision stages, combining a capability of large stroke, spin motion, and active rejection of disturbances.
|
||
First, the end station will be presented with the associated requirements. However, the precision is limited by thermal expansion and various imperfections that are not actively compensated.
|
||
Our approach is to add a Nano Active Stabilization System (NASS) which is composed of a 6DoF Stewart platform and a 6 DoF metrology system.
|
||
A 3D model of the end station updated with experimental data is developed.
|
||
As the mass of the samples may vary by up to two orders of magnitudes, robust control strategies are required to address such plant uncertainty.
|
||
The proposed control strategy are presented and applied on the developed model by conducting time domain simulations of tomography experiment in presence of instrumentation noise and system uncertainty.
|
||
</p>
|
||
</blockquote>
|
||
|
||
<div id="outline-container-orgf94d924" class="outline-2">
|
||
<h2 id="orgf94d924">Paper (<a href="paper/paper.pdf">link</a>)</h2>
|
||
<div class="outline-text-2" id="text-orgf94d924">
|
||
<p>
|
||
The paper has been created <a href="https://orgmode.org/">Org Mode</a> (generating <a href="https://www.latex-project.org/">LaTeX</a> code) under <a href="https://www.gnu.org/software/emacs/">Emacs</a>.
|
||
</p>
|
||
</div>
|
||
</div>
|
||
|
||
<div id="outline-container-orgc745e62" class="outline-2">
|
||
<h2 id="orgc745e62">Tikz Figures (<a href="tikz/index.html">link</a>)</h2>
|
||
<div class="outline-text-2" id="text-orgc745e62">
|
||
<p>
|
||
All the figures for the paper have been generated using <a href="https://sourceforge.net/projects/pgf/">TikZ</a>.
|
||
</p>
|
||
</div>
|
||
</div>
|
||
|
||
<div id="outline-container-orgb6f86f9" class="outline-2">
|
||
<h2 id="orgb6f86f9">Poster (<a href="poster/poster.pdf">link</a>)</h2>
|
||
<div class="outline-text-2" id="text-orgb6f86f9">
|
||
<p>
|
||
The poster has been created using the <a href="https://www.ctan.org/pkg/tikzposter">tikzposter</a> package for <a href="https://sourceforge.net/projects/latex-beamer/">beamer</a>.
|
||
</p>
|
||
</div>
|
||
</div>
|
||
|
||
<div id="outline-container-org91dc664" class="outline-2">
|
||
<h2 id="org91dc664">Talk (<a href="talk/talk.pdf">link</a>)</h2>
|
||
<div class="outline-text-2" id="text-org91dc664">
|
||
<p>
|
||
This work has been presented at <a href="https://indico.cern.ch/event/680538/">MEDSI 2018</a>.
|
||
</p>
|
||
</div>
|
||
</div>
|
||
|
||
<div id="outline-container-orgf1291b3" class="outline-2">
|
||
<h2 id="orgf1291b3">How to cite this paper</h2>
|
||
<div class="outline-text-2" id="text-orgf1291b3">
|
||
<p>
|
||
To cite this paper use the following bibtex code.
|
||
</p>
|
||
<div class="org-src-container">
|
||
<pre class="src src-bibtex"><span class="org-function-name">@inproceedings</span>{<span class="org-constant">dehaeze18_sampl_stabil_for_tomog_exper</span>,
|
||
<span class="org-variable-name">author</span> = {Thomas Dehaeze and M. Magnin Mattenet and Christophe Collette},
|
||
<span class="org-variable-name">title</span> = {Sample Stabilization For Tomography Experiments In Presence Of
|
||
Large Plant Uncertainty},
|
||
<span class="org-variable-name">booktitle</span> = {MEDSI'18},
|
||
<span class="org-variable-name">year</span> = 2018,
|
||
<span class="org-variable-name">number</span> = 10,
|
||
<span class="org-variable-name">pages</span> = {153--157},
|
||
<span class="org-variable-name">doi</span> = {<span class="org-button">10.18429/JACoW-MEDSI2018-WEOAMA02</span>},
|
||
<span class="org-variable-name">url</span> = {<span class="org-button">https://doi.org/10.18429/JACoW-MEDSI2018-WEOAMA02</span>},
|
||
<span class="org-variable-name">address</span> = {Geneva, Switzerland},
|
||
<span class="org-variable-name">isbn</span> = {978-3-95450-207-3},
|
||
<span class="org-variable-name">language</span> = {english},
|
||
<span class="org-variable-name">month</span> = {Dec},
|
||
<span class="org-variable-name">publisher</span> = {JACoW Publishing},
|
||
<span class="org-variable-name">series</span> = {Mechanical Engineering Design of Synchrotron Radiation
|
||
Equipment and Instrumentation},
|
||
<span class="org-variable-name">venue</span> = {Paris, France},
|
||
}
|
||
</pre>
|
||
</div>
|
||
|
||
<p>
|
||
You can also use the formatted citation below.
|
||
</p>
|
||
<blockquote>
|
||
<p>
|
||
Dehaeze, T., Mattenet, M. M., & Collette, C., Sample Stabilization For Tomography Experiments In Presence Of Large Plant Uncertainty, In MEDSI’18 (pp. 153–157) (2018). Geneva, Switzerland
|
||
</p>
|
||
</blockquote>
|
||
</div>
|
||
</div>
|
||
</div>
|
||
</body>
|
||
</html>
|