#+TITLE: List of measurements * Effect of control of each stage | Ty on | data_001 | | Ty off | data_002 | One geophone is on the marble, the other at the sample location. The signal from the top geophone goes through the slip-ring * Measurement when signal from top geophone does not go trought the slip-ring | Ty | Ry | Slip Ring | Spindle | Hexapod | Meas. file | |------+------+-----------+---------+---------+----------------| | *ON* | *ON* | *ON* | *ON* | *ON* | =meas_003.mat= | | OFF | *ON* | *ON* | *ON* | *ON* | =meas_004.mat= | | OFF | OFF | *ON* | *ON* | *ON* | =meas_005.mat= | | OFF | OFF | OFF | *ON* | *ON* | =meas_006.mat= | | OFF | OFF | OFF | OFF | *ON* | =meas_007.mat= | | OFF | OFF | OFF | OFF | OFF | =meas_008.mat= | Meas009: everything off with signal goes through the slip-ring * Measurement from one stage to the other ** From Marble to Ty =meas_010.mat= Everything off, one geophone on the marble, one geophone on the Ty (measure on Z direction) Channels: | 1 | Ground | | 2 | Ty | | 3 | Time | ** From Marble to Ry =meas_011.mat= Everything off, one geophone on the marble, one geophone on the Ry (measure on Z direction) Channels: | 1 | Ground | | 2 | Ry | | 3 | Time | ** From Ty to Ry =meas_012.mat= Everything off, one geophone on the Ty, one geophone on the Ry (measure on Z direction) Channels: | 1 | Ty | | 2 | Ry | | 3 | Time |