% Title: id31 microstation % Date: 12 january 2018 % Description: measure on id31 microstation in room id31-13 % --> check actual setup of microstation. % FS: =512Hz %% measurements 12 janaury 2018 microstation=['Marble '; 'Tilt '; 'Hexapod ']; % ch1: hammer % ch2: geophone L32 on marble X,Y or Z % ch3: geophone L32 on tilt stage X,Y or Z % ch4: geophone L32 on hexapode X,Y or Z % L32 geophone has a 4.5Hz resonance, not critically damped during these measurements! % Meas1 - excitation X direction on marble % Meas2 - excitation X direction on hexa % Meas3 - excitation Y direction on marble % Meas4 - excitation Y direction on hexa % Meas5 - excitation Z direction on marble % Meas6 - excitation Z direction on hexa %% Figure naming: % xxx_marble_x - excitation X direction on marble % xxx_marble_y - excitation Y direction on marble % xxx_marble_z - excitation Z direction on marble % xxx_hexa_x - excitation X direction on hexa % xxx_hexa_y - excitation Y direction on hexa % xxx_hexa_z - excitation Z direction on hexa % frf= transfert function velocity/force en ms-1/N (complex) % phs= phase % coh= coherence % freq_frf= frequencies