+++ title = "Interferometers" author = ["Thomas Dehaeze"] draft = false +++ Backlinks: - [Position Sensors]({{< relref "position_sensors" >}}) Tags : [Position Sensors]({{< relref "position_sensors" >}}) ## Manufacturers {#manufacturers} | Manufacturers | Links | Country | |---------------|----------------------------------------------------------------------------------------------------------|-------------| | Attocube | [link](http://www.attocube.com/) | Germany | | Zygo | [link](https://www.zygo.com/?/met/markets/stageposition/zmi/) | USA | | Smaract | [link](https://www.smaract.com/interferometry) | Germany | | Qutools | [link](https://www.qutools.com/qudis/) | Germany | | Renishaw | [link](https://www.renishaw.com/en/fibre-optic-laser-encoder-products--6594) | UK | | Sios | [link](https://sios-de.com/products/length-measurement/laser-interferometer/) | Germany | | Keysight | [link](https://www.keysight.com/en/pc-1000000393%3Aepsg%3Apgr/laser-heads?nid=-536900395.0&cc=FR&lc=fre) | USA | | Optics11 | [link](https://optics11.com/) | Netherlands | ## Environmental Units {#environmental-units}
Table 1: Characteristics of Environmental Units
| | Temperature (\\(\pm\ ^oC\\)) | Pressure (\\(\pm\ hPa\\)) | Humidity \\(\pm\\% RH\\) | Wavelength Accuracy (\\(\pm\ \text{ppm}\\)) | |-----------|------------------------------|---------------------------|--------------------------|---------------------------------------------| | Attocube | 0.1 | 1 | 2 | 0.5 | | Renishaw | 0.2 | 1 | 6 | 1 | | Picoscale | 0.2 | 2 | 2 | 1 | ## Interferometer Precision {#interferometer-precision} ([Jang and Kim 2017](#orgc0eaaa4)) {{< figure src="/ox-hugo/position_sensor_interferometer_precision.png" caption="Figure 1: Expected precision of interferometer as a function of measured distance" >}} ## Sources of uncertainty {#sources-of-uncertainty} Sources of error in laser interferometry are well described in ([Ducourtieux 2018](#org2c23555)). It includes: - Laser Source Stability - Variation of refractive index of air, which is dependent of: - Temperature: \\(K\_T \approx 1 ppmK^{-1}\\) - Pressure: \\(K\_P \approx 0.27 ppm hPa^{-1}\\) - Humidity: \\(K\_{HR} \approx 0.01 ppm \% RH^{-1}\\) - These errors can partially be compensated using an environmental unit. - Air turbulence (Figure [2](#org92b4926)) - Non linearity {{< figure src="/ox-hugo/interferometers_air_turbulence.png" caption="Figure 2: Effect of air turbulences on measurement stability" >}} ## Bibliography {#bibliography} Ducourtieux, Sebastien. 2018. “Toward High Precision Position Control Using Laser Interferometry: Main Sources of Error.” . Jang, Yoon-Soo, and Seung-Woo Kim. 2017. “Compensation of the Refractive Index of Air in Laser Interferometer for Distance Measurement: A Review.” _International Journal of Precision Engineering and Manufacturing_ 18 (12):1881–90. .