title = "A new isotropic and decoupled 6-dof parallel manipulator"
author = ["Thomas Dehaeze"]
draft = false
GHissueID = 1
+++
Tags
: [Stewart Platforms]({{< relref "stewart_platforms" >}})
Reference
: (Legnani {\it et al.}, 2012)
Author(s)
: Legnani, G., Fassi, I., Giberti, H., Cinquemani, S., & Tosi, D.
Year
: 2012
- Concepts of isotropy and decoupling for parallel manipulators
- **isotropy**: the kinetostatic properties (same applicable force, same possible velocity, same stiffness) are identical in all directions (e.g. cubic configuration for Stewart platform)
- **decoupling**: each DoF of the end effector can be controlled by a **single** actuator (not the case for the Stewart platform)
Example of generated isotropic manipulator (not decoupled).
{{< figure src="/ox-hugo/legnani12_isotropy_gen.png" caption="Figure 1: Location of the leg axes using an isotropy generator" >}}
{{< figure src="/ox-hugo/legnani12_generated_isotropy.png" caption="Figure 2: Isotropic configuration" >}}
# Bibliography
Legnani, G., Fassi, I., Giberti, H., Cinquemani, S., & Tosi, D., *A new isotropic and decoupled 6-dof parallel manipulator*, Mechanism and Machine Theory, *58(nil)*, 64–81 (2012). http://dx.doi.org/10.1016/j.mechmachtheory.2012.07.008 [↩](#17295cbc2858c65ecc60d51b450233e3)