+++ title = "Six dof active vibration control using stewart platform with non-cubic configuration" author = ["Dehaeze Thomas"] draft = false +++ Tags : [Stewart Platforms]({{< relref "stewart_platforms.md" >}}), [Vibration Isolation]({{< relref "vibration_isolation.md" >}}) Reference : (Zhang et al. 2011) Author(s) : Zhang, Z., Liu, J., Mao, J., Guo, Y., & Ma, Y. Year : 2011 - **Non-cubic** stewart platform - **Flexible** joints - Magnetostrictive actuators - Strong coupled motions along different axes - Non-cubic architecture => permits to have larger workspace which was required - Structure parameters (radius of plates, length of struts) are determined by optimization of the condition number of the Jacobian matrix - **Accelerometers** for active isolation - Adaptive FIR filters for active isolation control {{< figure src="/ox-hugo/zhang11_platform.png" caption="Figure 1: Prototype of the non-cubic stewart platform" >}} ## Bibliography {#bibliography}
Zhang, Zhen, J Liu, Jq Mao, Yx Guo, and Yh Ma. 2011. “Six Dof Active Vibration Control Using Stewart Platform with Non-Cubic Configuration.” In 2011 6th Ieee Conference on Industrial Electronics and Applications, nil. doi:10.1109/iciea.2011.5975679.